Computed tomography (CT) technology has changed considerably in recent years with the introduction of increasing numbers of multiple detector arrays. There are several parameters specific to multi-detector computed tomography (MDCT) scanners that increase or decrease patient dose systematically compared to older single detector computed tomography (SDCT) scanners.
This document briefly reviews the MDCT technology, radiation dose in MDCT, including differences from SDCT and factors that affect dose, radiation risks, and the responsibilities for patient dose management. The document recommends that users need to understand the relationship between patient dose and image quality and be aware that image quality in CT is often higher than that necessary for diagnostic confidence. Automatic exposure control (AEC) does not totally free the operator from selection of scan parameters, and awareness of individual systems is important. Scanning protocols cannot simply be transferred between scanners from different manufacturers and should be determined for each MDCT. If the image quality is appropriately specified by the user, and suited to the clinical task, there will be a reduction in patient dose for most patients. Understanding of some parameters is not intuitive and the selection of image quality parameter values in AEC systems is not straightforward. Examples of some clinical situations have been included to demonstrate dose management, e.g. CT examinations of the chest, the heart for coronary calcium quantification and non-invasive coronary angiography, colonography, the urinary tract, children, pregnant patients, trauma cases, and CT guided interventions. CT is increasingly being used to replace conventional x-ray studies and it is important that patient dose is given careful consideration, particularly with repeated or multiple examinations.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: Books Puddle, New York, NY, USA
Zustand: New. Print on Demand pp. 80. Bestandsnummer des Verkäufers 26833888
Anzahl: 4 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. Print on Demand pp. 80. Bestandsnummer des Verkäufers 8062655
Anzahl: 4 verfügbar
Anbieter: Biblios, Frankfurt am main, HESSE, Deutschland
Zustand: New. PRINT ON DEMAND pp. 80. Bestandsnummer des Verkäufers 18833898
Anzahl: 4 verfügbar
Anbieter: California Books, Miami, FL, USA
Zustand: New. Bestandsnummer des Verkäufers I-9780702030475
Anzahl: Mehr als 20 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Computed tomography (CT) technology has changed considerably in recent years with the introduction of increasing numbers of multiple detector arrays. This book reviews the MDCT technology, radiation dose in MDCT, including differences from SDCT and factors . Bestandsnummer des Verkäufers 3004673807
Anzahl: Mehr als 20 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. ICRP Publication 102 | Icrp | Taschenbuch | Englisch | 2008 | SAGE Publications Ltd | EAN 9780702030475 | Verantwortliche Person für die EU: Libri GmbH, Europaallee 1, 36244 Bad Hersfeld, gpsr[at]libri[dot]de | Anbieter: preigu Print on Demand. Bestandsnummer des Verkäufers 134760942
Anzahl: 5 verfügbar
Anbieter: Revaluation Books, Exeter, Vereinigtes Königreich
Paperback. Zustand: Brand New. 79 pages. 9.21x6.38x0.08 inches. In Stock. Bestandsnummer des Verkäufers x-0702030473
Anzahl: 2 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering. Bestandsnummer des Verkäufers 9780702030475
Anzahl: 2 verfügbar