Over the last 15 years, high-performance liquid chromatogra phy (LC) has made the transition from an instrument used only by experts in research labs to a tool used for routine applications by relatively unskilled workers. With this transition have come in instrumentation and column technology. In major advances the past, the operator had to be a jack-of-all-trades, with a screw driver, soldering iron, and various wrenches as constant compan ions in the LC lab. Today, many instruments contain micropro cessors as powerful as those of mainframe computers of earlier days. With this technology has come a variety of self-diagnostic tools that allow the LC system to locate many of its own prob lems. Traditionally, well-honed LC troubleshooting skills have been a result of years of work at the bench. Today the LC system itself often can do a better job of troubleshooting than the operator can. Yet many of the problems of the past are still the major problems of today: air bubbles, check valves, detector lamps, and, of course, problems with the separation. An added pressure on the operator of today's LC system is that of productivity-the lab often cannot afford unnecessary downtime. This means that the operator has to be a troubleshooting expert, or has to have that expertise at his or her fingertips. The present book was written to provide this expertise in an easy-to-use format for users at all levels of experience.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Over the last 15 years, high-performance liquid chromatogra phy (LC) has made the transition from an instrument used only by experts in research labs to a tool used for routine applications by relatively unskilled workers. With this transition have come in instrumentation and column technology. In major advances the past, the operator had to be a jack-of-all-trades, with a screw driver, soldering iron, and various wrenches as constant compan ions in the LC lab. Today, many instruments contain micropro cessors as powerful as those of mainframe computers of earlier days. With this technology has come a variety of self-diagnostic tools that allow the LC system to locate many of its own prob lems. Traditionally, well-honed LC troubleshooting skills have been a result of years of work at the bench. Today the LC system itself often can do a better job of troubleshooting than the operator can. Yet many of the problems of the past are still the major problems of today: air bubbles, check valves, detector lamps, and, of course, problems with the separation. An added pressure on the operator of today's LC system is that of productivity-the lab often cannot afford unnecessary downtime. This means that the operator has to be a troubleshooting expert, or has to have that expertise at his or her fingertips. The present book was written to provide this expertise in an easy-to-use format for users at all levels of experience.
Major advances in instrumentation and technology have made high-performance liquid chromatography (HPLC) a pervasive tool in virtually all areas of chemical and biomedical research today. Despite HPLC's enormous growth, technical problems still bedevil most users at least occasionally. Based on their immensely successful short courses, Dolan and Snyder's landmark new book - "Troubleshooting LC Systems" - now makes available to every practicing chromatographer the authors' wealth of expertise from years of hands-on troubleshooting of real-world LC problems - problems that routinely cause crises and unproductive downtime in nearly every lab. Believing that successful troubleshooting requires an understanding of the basics, Dolan and Snyder open by setting forth all the fundamental principles of LC operation, then move on to a microscopic description of all the elements of LC devices, to lay out their optimal preventive maintenance routines, and ultimately to offer an unprecedentedly thorough treatment of each and every facet of troubleshooting. Displaying a special tutorial mastery - honed to a fineness during their ongoing teaching and consulting activities, and a well-received feature column in "LC Magazine" - the book's chapters cover: automation and robotics; approaches to troubleshooting; reactions of samples; basic separation techniques; valves, tubing, syringes; band broadening and tailing; preventive maintenance; column packing and flushing; individual LC modules; troubleshooting principles; reagents and buffering; specific problems in separation; ghost and vacancy peaks; quantitation and calibration; pumps, seals, and pistons; gradient elution problems; column composition; concentration and blockages; sample cleanup; temperature and mixing effects; detectors and recorders; and, column packing and flushing. In short, Dolan and Snyder's eminently practical new guide to Troubleshooting LC Systems is an essential laboratory handbook - one that empowers expert and novice chromatographer alike to solve every sort of practical laboratory problem on a day-to-day basis. No one using an LC system should be without it!
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: HPB-Red, Dallas, TX, USA
hardcover. Zustand: Good. Connecting readers with great books since 1972! Used textbooks may not include companion materials such as access codes, etc. May have some wear or writing/highlighting. We ship orders daily and Customer Service is our top priority! Bestandsnummer des Verkäufers S_395121439
Anzahl: 1 verfügbar
Anbieter: Better World Books, Mishawaka, IN, USA
Zustand: Good. Former library book; may include library markings. Used book that is in clean, average condition without any missing pages. Bestandsnummer des Verkäufers GRP64564610
Anzahl: 1 verfügbar
Anbieter: ThriftBooks-Dallas, Dallas, TX, USA
Hardcover. Zustand: Good. No Jacket. Pages can have notes/highlighting. Spine may show signs of wear. ~ ThriftBooks: Read More, Spend Less. Bestandsnummer des Verkäufers G0896031519I3N00
Anzahl: 1 verfügbar
Anbieter: Source Bookstore, Davenport, IA, USA
Zustand: Good. Hardcover; Humana Press; 1989; Black cloth, silver lettering, X-Library. Bestandsnummer des Verkäufers 009753
Anzahl: 1 verfügbar
Anbieter: Bernhard Kiewel Rare Books, Grünberg, Deutschland
24 x 18. 515 Seiten. Hardcover mit Original-Schutzumschlag. Ordnungsgemäß aus einer Universitäts-Bibliothek ausgesondert (Stempel, Rückenschild). Umschlag mit Randläsuren, innen bis auf einige handschriftliche Anmerkungen guter Zustand. Gewicht über 1 kg. Sprache: Englisch Gewicht in Gramm: 1250. Bestandsnummer des Verkäufers 133254
Anzahl: 1 verfügbar
Anbieter: Rob the Book Man, Vancouver, WA, USA
Hardcover. Zustand: Near Fine. Zustand des Schutzumschlags: Near Fine. Hardback in near fine condition with near fine dust jacket. Previous owner's name on inside of front cover, otherwise clean. Bestandsnummer des Verkäufers 23551
Anzahl: 1 verfügbar
Anbieter: Toscana Books, AUSTIN, TX, USA
Hardcover. Zustand: new. Excellent Condition.Excels in customer satisfaction, prompt replies, and quality checks. Bestandsnummer des Verkäufers Scanned0896031519
Anzahl: 1 verfügbar
Anbieter: DeckleEdge LLC, Albuquerque, NM, USA
hardcover. Zustand: new. Bestandsnummer des Verkäufers Shelfdream0896031519
Anbieter: Buchpark, Trebbin, Deutschland
Zustand: Sehr gut. Zustand: Sehr gut | Seiten: 524 | Sprache: Englisch | Produktart: Bücher | Over the last 15 years, high-performance liquid chromatogra phy (LC) has made the transition from an instrument used only by experts in research labs to a tool used for routine applications by relatively unskilled workers. With this transition have come in instrumentation and column technology. In major advances the past, the operator had to be a jack-of-all-trades, with a screw driver, soldering iron, and various wrenches as constant compan ions in the LC lab. Today, many instruments contain micropro cessors as powerful as those of mainframe computers of earlier days. With this technology has come a variety of self-diagnostic tools that allow the LC system to locate many of its own prob lems. Traditionally, well-honed LC troubleshooting skills have been a result of years of work at the bench. Today the LC system itself often can do a better job of troubleshooting than the operator can. Yet many of the problems of the past are still the major problems of today: air bubbles, check valves, detector lamps, and, of course, problems with the separation. An added pressure on the operator of today's LC system is that of productivity-the lab often cannot afford unnecessary downtime. This means that the operator has to be a troubleshooting expert, or has to have that expertise at his or her fingertips. The present book was written to provide this expertise in an easy-to-use format for users at all levels of experience. Bestandsnummer des Verkäufers 3232451/2
Anzahl: 1 verfügbar
Anbieter: BennettBooksLtd, San Diego, NV, USA
hardcover. Zustand: New. In shrink wrap. Looks like an interesting title! Bestandsnummer des Verkäufers Q-0896031519
Anzahl: 1 verfügbar