Verwandte Artikel zu Electrical machine design; the design and specification...

Electrical machine design; the design and specification of direct and alternating current machinery - Softcover

 
9781235901058: Electrical machine design; the design and specification of direct and alternating current machinery

Inhaltsangabe

This historic book may have numerous typos and missing text. Purchasers can download a free scanned copy of the original book (without typos) from the publisher. Not indexed. Not illustrated. 1913 Excerpt: ...= 3450 ampere-turns. f AT mm = the maximum excitation =3X3450 = 10,400 ampere-turns, approximately. r, 2400. E--the voltage per phase =-_., since the connection is 1' fa = the flux per pole 1.73 = 1380 1380X108 2.22 X 0.96 X 72 X 12 X 60 3 = 3.8X10" If = the leakage factor, is assumed to be = 1.2. 3.8X10"X1.2 Plearea--9W = 48 sq. in. Lp = the axial length of the pole, is made 0.5 in. shorter than the frame length and =11.75 in. 117.1. 1 ' 48 S1' H P = the pole waist "0795x11.75 = 4.25 in. df. the depth of the field coil =0.75 in. from the table on page 240. MT = the mean turn =2(11.75 + 4.25) +-X 1.25 = 36 in. External periphery of field coil =38 in..... 10.400X36 M, the section of field wire = = 37,500 circular mils = 0.03 sq. in. = 0.04 X 0.75 (strip copper wound on edge) Watts per square inch for 65 C. rise =6.3 from Fig. 177, page 239. sf the spacc ffictor------0.04 + thickness of insulation = 0.8 using paper which is 0.01 in. thick ' 36: 6.3 X 0.75 X 0.8 X 1.27 = 4.75 in. 4 75 Tr, the number of turns per pole = „ „ 0.05 = 95 turns. The maximum exciting current =' raz--10,400 95 = 110 amperes Maximum output from exciter =120x110 = 13 kw. = 3.25 per cent. of the volt ampere rating. AT'g, the gap ampere-turns per pole at normal voltage and no-load,--ATmax--1.5X armature AT. per pole, approximately = 10,400-1.5x3450 = 5200 ampere-turns. ip, the pole enclosure, is taken as 0.65 which is an average value; if the pole arc be made too large, the pole leakage becomes excessive and the leakage factor high. Bg, the apparent gap density "josisxtz = 42,500 lines per square inch. _5200 X 3.2 "X C 42500 = 0.39 in. C = the Carter coefficient =1.12 from Fig. 40, page 44 3 = the air gap in inches =0.35 Calculation of the leakage fact...

Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.

Reseña del editor

This historic book may have numerous typos and missing text. Purchasers can download a free scanned copy of the original book (without typos) from the publisher. Not indexed. Not illustrated. 1913 Excerpt: ...= 3450 ampere-turns. f AT mm = the maximum excitation =3X3450 = 10,400 ampere-turns, approximately. r, 2400. E--the voltage per phase =-_., since the connection is 1' fa = the flux per pole 1.73 = 1380 1380X108 2.22 X 0.96 X 72 X 12 X 60 3 = 3.8X10" If = the leakage factor, is assumed to be = 1.2. 3.8X10"X1.2 Plearea--9W = 48 sq. in. Lp = the axial length of the pole, is made 0.5 in. shorter than the frame length and =11.75 in. 117.1. 1 ' 48 S1' H P = the pole waist "0795x11.75 = 4.25 in. df. the depth of the field coil =0.75 in. from the table on page 240. MT = the mean turn =2(11.75 + 4.25) +-X 1.25 = 36 in. External periphery of field coil =38 in..... 10.400X36 M, the section of field wire = = 37,500 circular mils = 0.03 sq. in. = 0.04 X 0.75 (strip copper wound on edge) Watts per square inch for 65 C. rise =6.3 from Fig. 177, page 239. sf the spacc ffictor------0.04 + thickness of insulation = 0.8 using paper which is 0.01 in. thick ' 36: 6.3 X 0.75 X 0.8 X 1.27 = 4.75 in. 4 75 Tr, the number of turns per pole = „ „ 0.05 = 95 turns. The maximum exciting current =' raz--10,400 95 = 110 amperes Maximum output from exciter =120x110 = 13 kw. = 3.25 per cent. of the volt ampere rating. AT'g, the gap ampere-turns per pole at normal voltage and no-load,--ATmax--1.5X armature AT. per pole, approximately = 10,400-1.5x3450 = 5200 ampere-turns. ip, the pole enclosure, is taken as 0.65 which is an average value; if the pole arc be made too large, the pole leakage becomes excessive and the leakage factor high. Bg, the apparent gap density "josisxtz = 42,500 lines per square inch. _5200 X 3.2 "X C 42500 = 0.39 in. C = the Carter coefficient =1.12 from Fig. 40, page 44 3 = the air gap in inches =0.35 Calculation of the leakage fact...

„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.

Gebraucht kaufen

Zustand: Wie neu
Like New
Diesen Artikel anzeigen

EUR 28,81 für den Versand von Vereinigtes Königreich nach USA

Versandziele, Kosten & Dauer

Suchergebnisse für Electrical machine design; the design and specification...

Beispielbild für diese ISBN

Gray, Alexander
Verlag: RareBooksClub.com, 2012
ISBN 10: 123590105X ISBN 13: 9781235901058
Gebraucht Paperback

Anbieter: Mispah books, Redhill, SURRE, Vereinigtes Königreich

Verkäuferbewertung 4 von 5 Sternen 4 Sterne, Erfahren Sie mehr über Verkäufer-Bewertungen

Paperback. Zustand: Like New. Like New. book. Bestandsnummer des Verkäufers ERICA775123590105X6

Verkäufer kontaktieren

Gebraucht kaufen

EUR 64,10
Währung umrechnen
Versand: EUR 28,81
Von Vereinigtes Königreich nach USA
Versandziele, Kosten & Dauer

Anzahl: 1 verfügbar

In den Warenkorb