This report provides key results of a six-month feasibility study on the effects of normal aging on the performance of pressure transmitters in nuclear power plants. Using experimental methods for response time testing of transmitters and aging tests on representative transmitters, the authors found that five reasonably effective methods are available for response time testing of pressure transmitters, two of which provide on-line measurement capability. The authors show that 38 percent of the problems reported in the 1,325 cases of the U.S. NRC's Licensee Event Report database over a nine-year period involved potential age-related cases such as calibration shifts and response time degradation.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: GreatBookPrices, Columbia, MD, USA
Zustand: New. Bestandsnummer des Verkäufers 21606325-n
Anzahl: Mehr als 20 verfügbar
Anbieter: California Books, Miami, FL, USA
Zustand: New. Print on Demand. Bestandsnummer des Verkäufers I-9781499140118
Anzahl: Mehr als 20 verfügbar
Anbieter: GreatBookPrices, Columbia, MD, USA
Zustand: As New. Unread book in perfect condition. Bestandsnummer des Verkäufers 21606325
Anzahl: Mehr als 20 verfügbar
Anbieter: GreatBookPricesUK, Woodford Green, Vereinigtes Königreich
Zustand: As New. Unread book in perfect condition. Bestandsnummer des Verkäufers 21606325
Anzahl: Mehr als 20 verfügbar
Anbieter: THE SAINT BOOKSTORE, Southport, Vereinigtes Königreich
Paperback / softback. Zustand: New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days. Bestandsnummer des Verkäufers C9781499140118
Anzahl: Mehr als 20 verfügbar
Anbieter: GreatBookPricesUK, Woodford Green, Vereinigtes Königreich
Zustand: New. Bestandsnummer des Verkäufers 21606325-n
Anzahl: Mehr als 20 verfügbar
Anbieter: CitiRetail, Stevenage, Vereinigtes Königreich
Paperback. Zustand: new. Paperback. This report provides key results of a six-month feasibility study on the effects of normal aging on the performance of pressure transmitters in nuclear power plants. Using experimental methods for response time testing of transmitters and aging tests on representative transmitters, the authors found that five reasonably effective methods are available for response time testing of pressure transmitters, two of which provide on-line measurement capability. The authors show that 38 percent of the problems reported in the 1,325 cases of the U.S. NRC's Licensee Event Report database over a nine-year period involved potential age-related cases such as calibration shifts and response time degradation. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability. Bestandsnummer des Verkäufers 9781499140118
Anzahl: 1 verfügbar