This book presents a precise approach for defect sizing using ultrasonics. It describes an alternative to the current European and American standards by neglecting their limitations. The approach presented here is not only valid for conventional angle beam probes, but also for phased array angle beam probes. It introduces an improved method which provides a significant productivity gain and calculates curves with high accuracy. Its content is of interest to all those working with distance gain size (DGS) methods or are using distance amplitude correction (DAC) curves.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Wolf Kleinert started his career in ultrasonic material testing in the year 1982 at the Krautkrämer Company in Cologne, Germany. He had a plurality of managerial assignments in Product-, Marketing- and Sales-Management, Intellectual Property Management as well as General Management. He was responsible for the Application Laboratory and heavily involved in the development of new probe technologies. End of 2014 Wolf retired after nearly 33 years in ultrasonic material testing.
This book presents a precise approach for defect sizing using ultrasonics. It describes an alternative to the current European and American standards by neglecting their limitations. The approach presented here is not only valid for conventional angle beam probes, but also for phased array angle beam probes. It introduces an improved method which provides a significant productivity gain and calculates curves with high accuracy. Its content is of interest to all those working with distance gain size (DGS) methods or are using distance ampllitude correction (DAC) curves.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: Books From California, Simi Valley, CA, USA
paperback. Zustand: Very Good. Bestandsnummer des Verkäufers mon0003991148
Anzahl: 1 verfügbar
Anbieter: Brook Bookstore On Demand, Napoli, NA, Italien
Zustand: new. Questo è un articolo print on demand. Bestandsnummer des Verkäufers 7fe0cbcaead26be14e4039943e3e74e0
Anzahl: Mehr als 20 verfügbar
Anbieter: GreatBookPrices, Columbia, MD, USA
Zustand: New. Bestandsnummer des Verkäufers 33169339-n
Anzahl: 15 verfügbar
Anbieter: GreatBookPrices, Columbia, MD, USA
Zustand: As New. Unread book in perfect condition. Bestandsnummer des Verkäufers 33169339
Anzahl: 15 verfügbar
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book presents a precise approach for defect sizing using ultrasonics. It describes an alternative to the current European and American standards by neglecting their limitations. The approach presented here is not only valid for conventional angle beam probes, but also for phased array angle beam probes. It introduces an improved method which provides a significant productivity gain and calculates curves with high accuracy. Its content is of interest to all those working with distance gain size (DGS) methods or are using distance amplitudecorrection (DAC) curves. 118 pp. Englisch. Bestandsnummer des Verkäufers 9783319813790
Anzahl: 2 verfügbar
Anbieter: Ria Christie Collections, Uxbridge, Vereinigtes Königreich
Zustand: New. In English. Bestandsnummer des Verkäufers ria9783319813790_new
Anzahl: Mehr als 20 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. Druck auf Anfrage Neuware - Printed after ordering - This book presents a precise approach for defect sizing using ultrasonics. It describes an alternative to the current European and American standards by neglecting their limitations. The approach presented here is not only valid for conventional angle beam probes, but also for phased array angle beam probes. It introduces an improved method which provides a significant productivity gain and calculates curves with high accuracy. Its content is of interest to all those working with distance gain size (DGS) methods or are using distance amplitudecorrection (DAC) curves. Bestandsnummer des Verkäufers 9783319813790
Anzahl: 2 verfügbar
Anbieter: Books Puddle, Woodside, NY, USA
Zustand: New. pp. XVIII, 118 90 illus., 83 illus. in color. 1 Edition NO-PA16APR2015-KAP. Bestandsnummer des Verkäufers 26384558249
Anzahl: 4 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Defect Sizing Using Non-destructive Ultrasonic Testing | Applying Bandwidth-Dependent DAC and DGS Curves | Wolf Kleinert | Taschenbuch | xviii | Englisch | 2018 | Springer | EAN 9783319813790 | Verantwortliche Person für die EU: Springer Verlag GmbH, Tiergartenstr. 17, 69121 Heidelberg, juergen[dot]hartmann[at]springer[dot]com | Anbieter: preigu. Bestandsnummer des Verkäufers 114226439
Anzahl: 5 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. Print on Demand pp. XVIII, 118 90 illus., 83 illus. in color. Bestandsnummer des Verkäufers 379345782
Anzahl: 4 verfügbar