A rapid, sensitive, and specific RP-HPLC method with UV detection was developed and validated for the determination of voriconazole. Chromatography was performed on an Enable C18 G column (250 × 4.6 mm) in isocratic mode, using a mobile phase of methanol and acetonitrile (60:40, v/v). The flow rate was set at 1 mL/min, and the effluent was monitored at 223 nm. Chromatographic analysis revealed a main peak for voriconazole at a retention time of 2.841 minutes. Methanol was selected as the solvent for the analysis, with the λmax determined to be 223 nm. The method exhibited linearity over a concentration range of 5–30 µg/mL. Validation parameters, including linearity, range, precision, accuracy, limit of detection (LOD), and limit of quantitation (LOQ), were assessed and met the required standards.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
The author earned his B.Pharmacy, M.Pharm, and Ph.D. from Andhra University. His postdoctoral research at Kyoto Pharmaceutical University, Japan, focused on designing and evaluating microneedle drug delivery systems for controlled release. He received the "Young Scientist Award-2016" from CEGR, New Delhi, and won four Best Research Paper Awards.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: PBShop.store US, Wood Dale, IL, USA
PAP. Zustand: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Bestandsnummer des Verkäufers L0-9783330051331
Anzahl: Mehr als 20 verfügbar
Anbieter: PBShop.store UK, Fairford, GLOS, Vereinigtes Königreich
PAP. Zustand: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Bestandsnummer des Verkäufers L0-9783330051331
Anzahl: Mehr als 20 verfügbar
Anbieter: California Books, Miami, FL, USA
Zustand: New. Bestandsnummer des Verkäufers I-9783330051331
Anzahl: Mehr als 20 verfügbar
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware 80 pp. Englisch. Bestandsnummer des Verkäufers 9783330051331
Anzahl: 2 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A rapid, sensitive, and specific RP-HPLC method with UV detection was developed and validated for the determination of voriconazole. Chromatography was performed on an Enable C18 G column (250 × 4.6 mm) in isocratic mode, using a mobile phase of methanol and acetonitrile (60:40, v/v). The flow rate was set at 1 mL/min, and the effluent was monitored at 223 nm. Chromatographic analysis revealed a main peak for voriconazole at a retention time of 2.841 minutes. Methanol was selected as the solvent for the analysis, with the max determined to be 223 nm. The method exhibited linearity over a concentration range of 5-30 µg/mL. Validation parameters, including linearity, range, precision, accuracy, limit of detection (LOD), and limit of quantitation (LOQ), were assessed and met the required standards. Bestandsnummer des Verkäufers 9783330051331
Anzahl: 1 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -A rapid, sensitive, and specific RP-HPLC method with UV detection was developed and validated for the determination of voriconazole. Chromatography was performed on an Enable C18 G column (250 × 4.6 mm) in isocratic mode, using a mobile phase of methanol and acetonitrile (60:40, v/v). The flow rate was set at 1 mL/min, and the effluent was monitored at 223 nm. Chromatographic analysis revealed a main peak for voriconazole at a retention time of 2.841 minutes. Methanol was selected as the solvent for the analysis, with the ¿max determined to be 223 nm. The method exhibited linearity over a concentration range of 5-30 µg/mL. Validation parameters, including linearity, range, precision, accuracy, limit of detection (LOD), and limit of quantitation (LOQ), were assessed and met the required standards.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 80 pp. Englisch. Bestandsnummer des Verkäufers 9783330051331
Anzahl: 1 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Method Development and Validation for Voriconazole Estimation | RP-HPLC and UV Spectrophotometric Methods in Bulk and Pharmaceutical Formulations | Yarguntla Srinivasa Rao (u. a.) | Taschenbuch | Englisch | 2024 | LAP LAMBERT Academic Publishing | EAN 9783330051331 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 130811660
Anzahl: 5 verfügbar