This study aimed to determine the optimum source to image distance (SID) for key radiographic projections, in diagnostic radiology. Three secondary aims were to determine the effect of changes in SID on the amount of scattered radiation at the image receptor, to determine the effect of changes in SID on the radiation dose to the patient and to assess any effects of changes in SID on the quality of the images. The study was performed using Monte Carlo simulation, employing EGSnrcMP and PCXMC. The Monte Carlo codes were benchmarked against independent experimental studies and shown to give excellent agreement. The conclusion was that for imaging of the trunk, other than the chest, the use of an SID of 150 cm will enable optimization of doses to patients. To optimize image quality and patient dose, a number of recommendations are made for technological improvements and for clinical practice.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Dr John Poletti has an MSc in Nuclear Physics from the University of Auckland, and a PhD in Radiology Physics from the University of Sydney. Formerly he was a Scientist at the National Radiation Laboratory in Christchurch, New Zealand. He is currently a Senior Lecturer at Unitec Institute of Technology, Auckland, New Zealand.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: moluna, Greven, Deutschland
Kartoniert / Broschiert. Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Poletti JohnDr John Poletti has an MSc in Nuclear Physics from the Universitynof Auckland, and a PhD in Radiology Physics from the Universitynof Sydney. Formerly he was a Scientist at the National RadiationnLaboratory in Christchurch. Bestandsnummer des Verkäufers 4960102
Anzahl: Mehr als 20 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This study aimed to determine the optimum source toimage distance (SID) for key radiographicprojections, in diagnostic radiology. Threesecondary aims were to determine the effect ofchanges in SID on the amount of scattered radiationat the image receptor, to determine the effect ofchanges in SID on the radiation dose to the patientand to assess any effects of changes in SID on thequality of the images. The study was performed usingMonte Carlo simulation, employing EGSnrcMP and PCXMC.The Monte Carlo codes were benchmarked againstindependent experimental studies and shown to giveexcellent agreement. The conclusion was that forimaging of the trunk, other than the chest, the useof an SID of 150 cm will enable optimization of dosesto patients. To optimize image quality and patientdose, a number of recommendations are made fortechnological improvements and for clinical practice. Bestandsnummer des Verkäufers 9783639129335
Anzahl: 2 verfügbar
Anbieter: Books Puddle, Woodside, NY, USA
Zustand: New. pp. 200. Bestandsnummer des Verkäufers 26128749244
Anzahl: 4 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. Print on Demand pp. 200 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam. Bestandsnummer des Verkäufers 131805539
Anzahl: 4 verfügbar
Anbieter: Biblios, Frankfurt am main, HESSE, Deutschland
Zustand: New. PRINT ON DEMAND pp. 200. Bestandsnummer des Verkäufers 18128749238
Anzahl: 4 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Optimisation of Source to Image Distance in Diagnostic Radiology | A study using Monte Carlo simulation | John Poletti | Taschenbuch | Englisch | VDM Verlag Dr. Müller | EAN 9783639129335 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 101646739
Anzahl: 5 verfügbar
Anbieter: Mispah books, Redhill, SURRE, Vereinigtes Königreich
Paperback. Zustand: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Bestandsnummer des Verkäufers ERICA79036391293346
Anzahl: 1 verfügbar