Prostate biopsy is a definitive method of prostate cancer diagnosis and is critical for cancer staging and treatment planning, and requires image guidance to ensure targeting accuracy. Transrectal ultrasound (TRUS) imaging, the current standard imaging modality for guiding prostate biopsies, suffers from 20% cancer miss rate. Magnetic Resonance Image (MRI) guidance during prostate biopsy, if employed properly, can improve targeting accuracy because of superior soft-tissue contrast and volumetric imaging capabilities. For proper MRI-guidance, prostate motion between target planning and needle placement must be accounted for, and intra-operative imaging must be performed at high speed. Two questions are studied and answered in this work to address these concerns: is rigid image registration sufficient in tracking biopsy targets with a maximum error of 3 mm and how many intra-operative slices are required to obtain this accuracy? Simulated intra-operative data, phantom data, and MRI-guided robotic prostate biopsy data were used to assess tracking accuracy. Registration (motion compensation) times and accuracies are discussed to address clinical feasibility of the proposed algorithms.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Hadi Tadayyon obtained his Bachelor's degree from The University of Western Ontario, London, Ontario, Canada (2008), and Master's degree from Queen's University, Kingston, Ontario, Canada (2012), both in Electrical and Computer Engineering. He is currently a PhD candidate in Medical Biophysics, University of Toronto, Toronto, Canada.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Prostate biopsy is a definitive method of prostate cancer diagnosis and is critical for cancer staging and treatment planning, and requires image guidance to ensure targeting accuracy. Transrectal ultrasound (TRUS) imaging, the current standard imaging modality for guiding prostate biopsies, suffers from 20% cancer miss rate. Magnetic Resonance Image (MRI) guidance during prostate biopsy, if employed properly, can improve targeting accuracy because of superior soft-tissue contrast and volumetric imaging capabilities. For proper MRI-guidance, prostate motion between target planning and needle placement must be accounted for, and intra-operative imaging must be performed at high speed. Two questions are studied and answered in this work to address these concerns: is rigid image registration sufficient in tracking biopsy targets with a maximum error of 3 mm and how many intra-operative slices are required to obtain this accuracy Simulated intra-operative data, phantom data, and MRI-guided robotic prostate biopsy data were used to assess tracking accuracy. Registration (motion compensation) times and accuracies are discussed to address clinical feasibility of the proposed algorithms. 64 pp. Englisch. Bestandsnummer des Verkäufers 9783639512731
Anzahl: 2 verfügbar
Anbieter: Books Puddle, New York, NY, USA
Zustand: New. Bestandsnummer des Verkäufers 26133921695
Anzahl: 4 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. Print on Demand. Bestandsnummer des Verkäufers 126665792
Anzahl: 4 verfügbar
Anbieter: Biblios, Frankfurt am main, HESSE, Deutschland
Zustand: New. PRINT ON DEMAND. Bestandsnummer des Verkäufers 18133921685
Anzahl: 4 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Tadayyon HadiHadi Tadayyon obtained his Bachelor s degree from The University of Western Ontario, London, Ontario, Canada (2008), and Master s degree from Queen s University, Kingston, Ontario, Canada (2012), both in Electrical and C. Bestandsnummer des Verkäufers 4993005
Anzahl: Mehr als 20 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Prostate biopsy is a definitive method of prostate cancer diagnosis and is critical for cancer staging and treatment planning, and requires image guidance to ensure targeting accuracy. Transrectal ultrasound (TRUS) imaging, the current standard imaging modality for guiding prostate biopsies, suffers from 20% cancer miss rate. Magnetic Resonance Image (MRI) guidance during prostate biopsy, if employed properly, can improve targeting accuracy because of superior soft-tissue contrast and volumetric imaging capabilities. For proper MRI-guidance, prostate motion between target planning and needle placement must be accounted for, and intra-operative imaging must be performed at high speed. Two questions are studied and answered in this work to address these concerns: is rigid image registration sufficient in tracking biopsy targets with a maximum error of 3 mm and how many intra-operative slices are required to obtain this accuracy Simulated intra-operative data, phantom data, and MRI-guided robotic prostate biopsy data were used to assess tracking accuracy. Registration (motion compensation) times and accuracies are discussed to address clinical feasibility of the proposed algorithms.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 64 pp. Englisch. Bestandsnummer des Verkäufers 9783639512731
Anzahl: 1 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Prostate biopsy is a definitive method of prostate cancer diagnosis and is critical for cancer staging and treatment planning, and requires image guidance to ensure targeting accuracy. Transrectal ultrasound (TRUS) imaging, the current standard imaging modality for guiding prostate biopsies, suffers from 20% cancer miss rate. Magnetic Resonance Image (MRI) guidance during prostate biopsy, if employed properly, can improve targeting accuracy because of superior soft-tissue contrast and volumetric imaging capabilities. For proper MRI-guidance, prostate motion between target planning and needle placement must be accounted for, and intra-operative imaging must be performed at high speed. Two questions are studied and answered in this work to address these concerns: is rigid image registration sufficient in tracking biopsy targets with a maximum error of 3 mm and how many intra-operative slices are required to obtain this accuracy Simulated intra-operative data, phantom data, and MRI-guided robotic prostate biopsy data were used to assess tracking accuracy. Registration (motion compensation) times and accuracies are discussed to address clinical feasibility of the proposed algorithms. Bestandsnummer des Verkäufers 9783639512731
Anzahl: 1 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. MRI-Guided Prostate Motion Tracking | Using Multislice to Volume Registration | Hadi Tadayyon | Taschenbuch | 64 S. | Englisch | 2014 | Scholars' Press | EAN 9783639512731 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 106009524
Anzahl: 5 verfügbar
Anbieter: Mispah books, Redhill, SURRE, Vereinigtes Königreich
paperback. Zustand: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Bestandsnummer des Verkäufers ERICA82936395127316
Anzahl: 1 verfügbar