Islanding detection is an essential requirement of the modified power system scenario with increased penetration of DGs. A new detection technique based on wavelet energy entropy identification and active frequency drift confirmation approach has been proposed. Wavelet energy entropy is proposed as a solid indicator for possible islanding operation. As an active approach, frequency drift anti-islanding algorithm is proposed robustly shift the voltage frequency into the tripping window. The proposed method reduces time of detection leading to reliability. The technique also reduces non detection zone of passive method approximately to zero. These benefits of proposed method not only improve dependability of the detection but also overcome the power quality degradation issue of active method, as perturbation is not applied continuously in the system. The time taken by this dual level approach is much shorter than other hybrid methods as response time of wavelet entropy indicator is in ms and speed of active frequency drift is improved by adjusting parameters without any restriction on power quality degradation.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Smita Shrivastava received her B.E. and M.E. Degree from Government Engineering College Jabalpur India, and the Ph.D. degree from National Institute of Technology Bhopal India. Currently she is Professor in Hitkarini college of engineering and Technology Jabalpur. Her research interests include power system, distributed generation, renewable energy.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Islanding detection is an essential requirement of the modified power system scenario with increased penetration of DGs. A new detection technique based on wavelet energy entropy identification and active frequency drift confirmation approach has been proposed. Wavelet energy entropy is proposed as a solid indicator for possible islanding operation. As an active approach, frequency drift anti-islanding algorithm is proposed robustly shift the voltage frequency into the tripping window. The proposed method reduces time of detection leading to reliability. The technique also reduces non detection zone of passive method approximately to zero. These benefits of proposed method not only improve dependability of the detection but also overcome the power quality degradation issue of active method, as perturbation is not applied continuously in the system. The time taken by this dual level approach is much shorter than other hybrid methods as response time of wavelet entropy indicator is in ms and speed of active frequency drift is improved by adjusting parameters without any restriction on power quality degradation. 132 pp. Englisch. Bestandsnummer des Verkäufers 9783639710625
Anzahl: 2 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Islanding detection is an essential requirement of the modified power system scenario with increased penetration of DGs. A new detection technique based on wavelet energy entropy identification and active frequency drift confirmation approach has been proposed. Wavelet energy entropy is proposed as a solid indicator for possible islanding operation. As an active approach, frequency drift anti-islanding algorithm is proposed robustly shift the voltage frequency into the tripping window. The proposed method reduces time of detection leading to reliability. The technique also reduces non detection zone of passive method approximately to zero. These benefits of proposed method not only improve dependability of the detection but also overcome the power quality degradation issue of active method, as perturbation is not applied continuously in the system. The time taken by this dual level approach is much shorter than other hybrid methods as response time of wavelet entropy indicator is in ms and speed of active frequency drift is improved by adjusting parameters without any restriction on power quality degradation. Bestandsnummer des Verkäufers 9783639710625
Anzahl: 1 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Shrivastava SmitaSmita Shrivastava received her B.E. and M.E. Degree from Government Engineering College Jabalpur India, and the Ph.D. degree from National Institute of Technology Bhopal India. Currently she is Professor in Hitkarini. Bestandsnummer des Verkäufers 173836875
Anzahl: Mehr als 20 verfügbar
Anbieter: Revaluation Books, Exeter, Vereinigtes Königreich
Paperback. Zustand: Brand New. 132 pages. 8.66x5.91x0.30 inches. In Stock. Bestandsnummer des Verkäufers __3639710622
Anzahl: 1 verfügbar
Anbieter: Mispah books, Redhill, SURRE, Vereinigtes Königreich
paperback. Zustand: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Bestandsnummer des Verkäufers ERICA82936397106226
Anzahl: 1 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Islanding detection is an essential requirement of the modified power system scenario with increased penetration of DGs. A new detection technique based on wavelet energy entropy identification and active frequency drift confirmation approach has been proposed. Wavelet energy entropy is proposed as a solid indicator for possible islanding operation. As an active approach, frequency drift anti-islanding algorithm is proposed robustly shift the voltage frequency into the tripping window. The proposed method reduces time of detection leading to reliability. The technique also reduces non detection zone of passive method approximately to zero. These benefits of proposed method not only improve dependability of the detection but also overcome the power quality degradation issue of active method, as perturbation is not applied continuously in the system. The time taken by this dual level approach is much shorter than other hybrid methods as response time of wavelet entropy indicator is in ms and speed of active frequency drift is improved by adjusting parameters without any restriction on power quality degradation.OmniScriptum SRL, Str. Armeneasca 28/1, office 1, 2012 Chisinau 132 pp. Englisch. Bestandsnummer des Verkäufers 9783639710625
Anzahl: 1 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Improved Islanding Detection Methods For Distributed Generators | Smita Shrivastava (u. a.) | Taschenbuch | Englisch | 2017 | Scholars' Press | EAN 9783639710625 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 113175993
Anzahl: 5 verfügbar