Heart rate variability (HRV) analysis is considered a popular, non-invasive method for investigating autonomic regulation of cardiovascular system. However, inappropriate technical conditions can result in false and inaccurate measurement. Present booklet (based on the author’s still applicable PhD Dissertation from 2005) details the effects of analogue corner frequencies, AC notch filtering and sampling rate of uncorrupted and noise-corrupted ECG signals on the accuracy and precision of heart rate interval detection and HRV indices based on hardware and software simulation. Power line notch filtering is highly recommended and a bandwidth of 0.5-20Hz is considered sufficient, since neither of them deteriorate the accuracy and precision of heart rate detection, conversely, they improve it by suppressing unwanted noises and interferences. A sampling rate of 1ms is necessary for correct measurement of variability especially in patients with seriously reduced HRV; however, lower sampling frequency may be satisfactory when higher variability or larger differences are expected. Taking above technical considerations into account can improve the validity of HRV measurement.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Dr. Hejjel is an Associate professor and Head of the Division of Cardiac Surgery, Heart Institute, University of Pécs, Hungary. He habilitated in Multidisciplinary Medical Sciences. His research interests are patient monitoring, biomedical signal analysis, HRV measurement, epicardial pacing, surgery on the aorta, mechanical circulatory support.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Heart rate variability (HRV) analysis is considered a popular, non-invasive method for investigating autonomic regulation of cardiovascular system. However, inappropriate technical conditions can result in false and inaccurate measurement. Present booklet (based on the author¿s still applicable PhD Dissertation from 2005) details the effects of analogue corner frequencies, AC notch filtering and sampling rate of uncorrupted and noise-corrupted ECG signals on the accuracy and precision of heart rate interval detection and HRV indices based on hardware and software simulation. Power line notch filtering is highly recommended and a bandwidth of 0.5-20Hz is considered sufficient, since neither of them deteriorate the accuracy and precision of heart rate detection, conversely, they improve it by suppressing unwanted noises and interferences. A sampling rate of 1ms is necessary for correct measurement of variability especially in patients with seriously reduced HRV; however, lower sampling frequency may be satisfactory when higher variability or larger differences are expected. Taking above technical considerations into account can improve the validity of HRV measurement. 112 pp. Englisch. Bestandsnummer des Verkäufers 9783639734522
Anzahl: 2 verfügbar
Anbieter: Books Puddle, New York, NY, USA
Zustand: New. Bestandsnummer des Verkäufers 26394749509
Anzahl: 4 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. Print on Demand. Bestandsnummer des Verkäufers 401660314
Anzahl: 4 verfügbar
Anbieter: Biblios, Frankfurt am main, HESSE, Deutschland
Zustand: New. PRINT ON DEMAND. Bestandsnummer des Verkäufers 18394749519
Anzahl: 4 verfügbar
Anbieter: moluna, Greven, Deutschland
Kartoniert / Broschiert. Zustand: New. Bestandsnummer des Verkäufers 511495088
Anzahl: Mehr als 20 verfügbar
Anbieter: Revaluation Books, Exeter, Vereinigtes Königreich
Paperback. Zustand: Brand New. 112 pages. 8.66x5.91x0.26 inches. In Stock. Bestandsnummer des Verkäufers __3639734521
Anzahl: 1 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Heart rate variability (HRV) analysis is considered a popular, non-invasive method for investigating autonomic regulation of cardiovascular system. However, inappropriate technical conditions can result in false and inaccurate measurement. Present booklet (based on the author¿s still applicable PhD Dissertation from 2005) details the effects of analogue corner frequencies, AC notch filtering and sampling rate of uncorrupted and noise-corrupted ECG signals on the accuracy and precision of heart rate interval detection and HRV indices based on hardware and software simulation. Power line notch filtering is highly recommended and a bandwidth of 0.5-20Hz is considered sufficient, since neither of them deteriorate the accuracy and precision of heart rate detection, conversely, they improve it by suppressing unwanted noises and interferences. A sampling rate of 1ms is necessary for correct measurement of variability especially in patients with seriously reduced HRV; however, lower sampling frequency may be satisfactory when higher variability or larger differences are expected. Taking above technical considerations into account can improve the validity of HRV measurement.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 112 pp. Englisch. Bestandsnummer des Verkäufers 9783639734522
Anzahl: 1 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Heart rate variability (HRV) analysis is considered a popular, non-invasive method for investigating autonomic regulation of cardiovascular system. However, inappropriate technical conditions can result in false and inaccurate measurement. Present booklet (based on the author¿s still applicable PhD Dissertation from 2005) details the effects of analogue corner frequencies, AC notch filtering and sampling rate of uncorrupted and noise-corrupted ECG signals on the accuracy and precision of heart rate interval detection and HRV indices based on hardware and software simulation. Power line notch filtering is highly recommended and a bandwidth of 0.5-20Hz is considered sufficient, since neither of them deteriorate the accuracy and precision of heart rate detection, conversely, they improve it by suppressing unwanted noises and interferences. A sampling rate of 1ms is necessary for correct measurement of variability especially in patients with seriously reduced HRV; however, lower sampling frequency may be satisfactory when higher variability or larger differences are expected. Taking above technical considerations into account can improve the validity of HRV measurement. Bestandsnummer des Verkäufers 9783639734522
Anzahl: 1 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Technical pitfalls of heart rate variability analysis | Basic Technical Considerations for Accurate Measurement | László Hejjel | Taschenbuch | Englisch | 2016 | GlobeEdit | EAN 9783639734522 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu Print on Demand. Bestandsnummer des Verkäufers 120618156
Anzahl: 5 verfügbar