This book presents a novel method for optimal location of FACTS controllers in a multi machine power systems and also give the solution with each of the FACTS device. Using this proposed method, the location of FACTS controller, their type and rated values are analyzed and optimized simultaneously.With the aid of FACTS technology, namely Static Var Compensator (SVC), Thyristor Switched Capacitor Variable Reactor (TCVR) and Unified Power Flow Controller (UPFC) etc., the bus voltages, line impedances and phase angles in the power system can be controlled quickly and flexibly. In my paper IEEE standard 14 & 30 bus systems were taken for obtaining optimum solution.Simulation results shown that the obtained output is feasible and most accurate solution in the OPF solution. FACTS devices can direct the active and reactive power control and flexible to voltage-magnitude control simultaneously, because of their adaptability and fast control characteristics.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: moluna, Greven, Deutschland
Kartoniert / Broschiert. Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Easwaramoothy NandaKumarNandaKumar.E obtained his B.E. from Bharathidasan University, Trichy and M.E.from A.U. Chennai. Currently he is research Scholar in Anna University Coimbatore.He is currently working as an A.P. in the departme. Bestandsnummer des Verkäufers 5142477
Anzahl: Mehr als 20 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book presents a novel method for optimal location of FACTS controllers in a multi machine power systems and also give the solution with each of the FACTS device. Using this proposed method, the location of FACTS controller, their type and rated values are analyzed and optimized simultaneously.With the aid of FACTS technology, namely Static Var Compensator (SVC), Thyristor Switched Capacitor Variable Reactor (TCVR) and Unified Power Flow Controller (UPFC) etc., the bus voltages, line impedances and phase angles in the power system can be controlled quickly and flexibly. In my paper IEEE standard 14 & 30 bus systems were taken for obtaining optimum solution.Simulation results shown that the obtained output is feasible and most accurate solution in the OPF solution. FACTS devices can direct the active and reactive power control and flexible to voltage-magnitude control simultaneously, because of their adaptability and fast control characteristics. Bestandsnummer des Verkäufers 9783659243004
Anzahl: 2 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Simulation of OPF Problem incorporating various FACTS Devices | Solution of OPF Problem with FACTS Devices | NandaKumar Easwaramoothy (u. a.) | Taschenbuch | Englisch | LAP Lambert Academic Publishing | EAN 9783659243004 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 106262439
Anzahl: 5 verfügbar
Anbieter: Mispah books, Redhill, SURRE, Vereinigtes Königreich
paperback. Zustand: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Bestandsnummer des Verkäufers ERICA82936592430006
Anzahl: 1 verfügbar