This report presents the results of dynamic monitoring test carried out at a jacket-type offshore platform. The dynamic measurements consisted of vibration measurements with high accuracy equipment in twelve different positions located on the decks of the structure. The source of excitation was solely the ambient vibration by waves, wind and equipment on the structure under normal operation conditions. A large amount of measured data were analysed by advanced digital signal analysis techniques, followed by the extraction of structural modes. Then, a updated numerical model of the structure was assembled and then employed to analyse the structural behaviour under various loading scenarios including seismic loading. The main conclusion is that the 50 years old oil rig structure is unable to sustain some specific loading scenarios, according to current API-RP-2A-WSD (2000) standard. Structural rehabilitation is not totally feasible, as the structure will not be safe against seismic loadings. On the other hand, it is possible to rehabilitate this structure, provided seismic loadings are not taken into account.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Doctorate in Civil Engineering from the Federal University of Rio de Janeiro (2004). Has designs and researchs in Structural Engineering, acting on the following topics: Steel and concrete structures, offshore structures, soil-structure interaction, structural dynamics and finite elements.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: PBShop.store US, Wood Dale, IL, USA
PAP. Zustand: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Bestandsnummer des Verkäufers L0-9783659330407
Anzahl: Mehr als 20 verfügbar
Anbieter: PBShop.store UK, Fairford, GLOS, Vereinigtes Königreich
PAP. Zustand: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Bestandsnummer des Verkäufers L0-9783659330407
Anzahl: Mehr als 20 verfügbar
Anbieter: Ria Christie Collections, Uxbridge, Vereinigtes Königreich
Zustand: New. In. Bestandsnummer des Verkäufers ria9783659330407_new
Anzahl: Mehr als 20 verfügbar
Anbieter: Chiron Media, Wallingford, Vereinigtes Königreich
Paperback. Zustand: New. Bestandsnummer des Verkäufers 6666-IUK-9783659330407
Anzahl: 10 verfügbar
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This report presents the results of dynamic monitoring test carried out at a jacket-type offshore platform. The dynamic measurements consisted of vibration measurements with high accuracy equipment in twelve different positions located on the decks of the structure. The source of excitation was solely the ambient vibration by waves, wind and equipment on the structure under normal operation conditions. A large amount of measured data were analysed by advanced digital signal analysis techniques, followed by the extraction of structural modes. Then, a updated numerical model of the structure was assembled and then employed to analyse the structural behaviour under various loading scenarios including seismic loading. The main conclusion is that the 50 years old oil rig structure is unable to sustain some specific loading scenarios, according to current API-RP-2A-WSD (2000) standard. Structural rehabilitation is not totally feasible, as the structure will not be safe against seismic loadings. On the other hand, it is possible to rehabilitate this structure, provided seismic loadings are not taken into account. 100 pp. Englisch. Bestandsnummer des Verkäufers 9783659330407
Anzahl: 2 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Bestandsnummer des Verkäufers 17694295
Anzahl: Mehr als 20 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This report presents the results of dynamic monitoring test carried out at a jacket-type offshore platform. The dynamic measurements consisted of vibration measurements with high accuracy equipment in twelve different positions located on the decks of the structure. The source of excitation was solely the ambient vibration by waves, wind and equipment on the structure under normal operation conditions. A large amount of measured data were analysed by advanced digital signal analysis techniques, followed by the extraction of structural modes. Then, a updated numerical model of the structure was assembled and then employed to analyse the structural behaviour under various loading scenarios including seismic loading. The main conclusion is that the 50 years old oil rig structure is unable to sustain some specific loading scenarios, according to current API-RP-2A-WSD (2000) standard. Structural rehabilitation is not totally feasible, as the structure will not be safe against seismic loadings. On the other hand, it is possible to rehabilitate this structure, provided seismic loadings are not taken into account.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 100 pp. Englisch. Bestandsnummer des Verkäufers 9783659330407
Anzahl: 1 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This report presents the results of dynamic monitoring test carried out at a jacket-type offshore platform. The dynamic measurements consisted of vibration measurements with high accuracy equipment in twelve different positions located on the decks of the structure. The source of excitation was solely the ambient vibration by waves, wind and equipment on the structure under normal operation conditions. A large amount of measured data were analysed by advanced digital signal analysis techniques, followed by the extraction of structural modes. Then, a updated numerical model of the structure was assembled and then employed to analyse the structural behaviour under various loading scenarios including seismic loading. The main conclusion is that the 50 years old oil rig structure is unable to sustain some specific loading scenarios, according to current API-RP-2A-WSD (2000) standard. Structural rehabilitation is not totally feasible, as the structure will not be safe against seismic loadings. On the other hand, it is possible to rehabilitate this structure, provided seismic loadings are not taken into account. Bestandsnummer des Verkäufers 9783659330407
Anzahl: 1 verfügbar