Bulk power transfer by a vast expanded electrical power transmission network demands robustness and ability to withstand both internal and external adverse conditions that maybe experienced by the power transmission network. Therefore, the insulation of equipment, to be used in the power system, should be reliable enough to withstand these adverse conditions. To gauge the strength of the insulation used in power equipment or to understand the reasons of its failure, mathematical calculations are carried out to determine the transfer function of power equipment, which can be used for diagnosis in case of malfunctioning. Various factors affecting the testing setup and power equipment are taken into consideration. The results of mathematical calculations are compared with OrCAD PSpice & Wolfram Mathematica simulations to verify the integrity of mathematical technique proposed to determine the transfer function of a given power equipment. Transformer is used as power equipment in this research for the development technique for determination of transfer function.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Muhammad Umer Arshad did his B.Sc. & M.Sc., in Electrical Engineering in 2005 & 2012 respectively, from University of Engineering & Technology, Lahore, Pakistan. He is now serving as a Lecturer in the Department of Electrical Engineering at The University of Lahore, Lahore. His major research area is Power system optimization and High Voltage.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Bulk power transfer by a vast expanded electrical power transmission network demands robustness and ability to withstand both internal and external adverse conditions that maybe experienced by the power transmission network. Therefore, the insulation of equipment, to be used in the power system, should be reliable enough to withstand these adverse conditions. To gauge the strength of the insulation used in power equipment or to understand the reasons of its failure, mathematical calculations are carried out to determine the transfer function of power equipment, which can be used for diagnosis in case of malfunctioning. Various factors affecting the testing setup and power equipment are taken into consideration. The results of mathematical calculations are compared with OrCAD PSpice & Wolfram Mathematica simulations to verify the integrity of mathematical technique proposed to determine the transfer function of a given power equipment. Transformer is used as power equipment in this research for the development technique for determination of transfer function. 92 pp. Englisch. Bestandsnummer des Verkäufers 9783659451102
Anzahl: 2 verfügbar
Anbieter: Books Puddle, New York, NY, USA
Zustand: New. Bestandsnummer des Verkäufers 26396996046
Anzahl: 4 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Arshad Muhammad UmerMuhammad Umer Arshad did his B.Sc. & M.Sc., in Electrical Engineering in 2005 & 2012 respectively, from University of Engineering & Technology, Lahore, Pakistan. He is now serving as a Lecturer in the Department o. Bestandsnummer des Verkäufers 385766921
Anzahl: Mehr als 20 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. Print on Demand. Bestandsnummer des Verkäufers 400429585
Anzahl: 4 verfügbar
Anbieter: Biblios, Frankfurt am main, HESSE, Deutschland
Zustand: New. PRINT ON DEMAND. Bestandsnummer des Verkäufers 18396996036
Anzahl: 4 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. Neuware -Bulk power transfer by a vast expanded electrical power transmission network demands robustness and ability to withstand both internal and external adverse conditions that maybe experienced by the power transmission network. Therefore, the insulation of equipment, to be used in the power system, should be reliable enough to withstand these adverse conditions. To gauge the strength of the insulation used in power equipment or to understand the reasons of its failure, mathematical calculations are carried out to determine the transfer function of power equipment, which can be used for diagnosis in case of malfunctioning. Various factors affecting the testing setup and power equipment are taken into consideration. The results of mathematical calculations are compared with OrCAD PSpice & Wolfram Mathematica simulations to verify the integrity of mathematical technique proposed to determine the transfer function of a given power equipment. Transformer is used as power equipment in this research for the development technique for determination of transfer function.Books on Demand GmbH, Überseering 33, 22297 Hamburg 92 pp. Englisch. Bestandsnummer des Verkäufers 9783659451102
Anzahl: 2 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Bulk power transfer by a vast expanded electrical power transmission network demands robustness and ability to withstand both internal and external adverse conditions that maybe experienced by the power transmission network. Therefore, the insulation of equipment, to be used in the power system, should be reliable enough to withstand these adverse conditions. To gauge the strength of the insulation used in power equipment or to understand the reasons of its failure, mathematical calculations are carried out to determine the transfer function of power equipment, which can be used for diagnosis in case of malfunctioning. Various factors affecting the testing setup and power equipment are taken into consideration. The results of mathematical calculations are compared with OrCAD PSpice & Wolfram Mathematica simulations to verify the integrity of mathematical technique proposed to determine the transfer function of a given power equipment. Transformer is used as power equipment in this research for the development technique for determination of transfer function. Bestandsnummer des Verkäufers 9783659451102
Anzahl: 1 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Transfer Function Investigation Using Multi-Stage HV Impulse Generator | Transfer Function Investigation of Power Equipment Using Multi-Stage High Voltage Impulse Generator | Muhammad Umer Arshad (u. a.) | Taschenbuch | 92 S. | Englisch | 2013 | LAP LAMBERT Academic Publishing | EAN 9783659451102 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 113818775
Anzahl: 5 verfügbar