In this work developments are presented, which shift the technological frontiers in the field of powering and data communication for wearable and implantable medical systems and which may help the introduction of ambulatory monitoring and ambient intelligence in the near future. Inductive power transmission is proposed as a way to provide power to wearable and implantable electronic devices. The design trajectory of an inductive link is covered and optimization methods are proposed and successfully illustrated with an example. Next, the integration of bidirectional data transmission in the inductive link is treated. The major contribution is the use of one single inductive link for both the transmission of power and the bidirectional transmission of data. This drastically increases the ease of use of the system and decreases the dimensions of the secondary (implantable) circuit, as only on set of antennae is used. Two examples are the instrumentation of a hip prosthesis for the monitoring of early loosening in orthopaedics, and a smart suit for the monitoring of children in a hospital environment, containing dedicated textile sensors for respiration and ECG.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Robert (Bob) Puers, PhD. 1986 KULeuven. He is one of the European research pioneers in micromachining, MEMS and packaging techniques, mainly for biomedical implantable systems. IEEE and IoP fellow.Michael Catrysse, PhD. 2004 KULeuven. Expert in inductive powering for biomedical systems, instrumentation of orthopaedic implants and wearable textile
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In this work developments are presented, which shift the technological frontiers in the field of powering and data communication for wearable and implantable medical systems and which may help the introduction of ambulatory monitoring and ambient intelligence in the near future. Inductive power transmission is proposed as a way to provide power to wearable and implantable electronic devices. The design trajectory of an inductive link is covered and optimization methods are proposed and successfully illustrated with an example. Next, the integration of bidirectional data transmission in the inductive link is treated. The major contribution is the use of one single inductive link for both the transmission of power and the bidirectional transmission of data. This drastically increases the ease of use of the system and decreases the dimensions of the secondary (implantable) circuit, as only on set of antennae is used. Two examples are the instrumentation of a hip prosthesis for the monitoring of early loosening in orthopaedics, and a smart suit for the monitoring of children in a hospital environment, containing dedicated textile sensors for respiration and ECG. 200 pp. Englisch. Bestandsnummer des Verkäufers 9783659759048
Anzahl: 2 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Puers RobertRobert (Bob) Puers, PhD. 1986 KULeuven. He is one of the European research pioneers in micromachining, MEMS and packaging techniques, mainly for biomedical implantable systems. IEEE and IoP fellow.Michael Catrysse, PhD. 2. Bestandsnummer des Verkäufers 159144686
Anzahl: Mehr als 20 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In this work developments are presented, which shift the technological frontiers in the field of powering and data communication for wearable and implantable medical systems and which may help the introduction of ambulatory monitoring and ambient intelligence in the near future. Inductive power transmission is proposed as a way to provide power to wearable and implantable electronic devices. The design trajectory of an inductive link is covered and optimization methods are proposed and successfully illustrated with an example. Next, the integration of bidirectional data transmission in the inductive link is treated. The major contribution is the use of one single inductive link for both the transmission of power and the bidirectional transmission of data. This drastically increases the ease of use of the system and decreases the dimensions of the secondary (implantable) circuit, as only on set of antennae is used. Two examples are the instrumentation of a hip prosthesis for the monitoring of early loosening in orthopaedics, and a smart suit for the monitoring of children in a hospital environment, containing dedicated textile sensors for respiration and ECG. Bestandsnummer des Verkäufers 9783659759048
Anzahl: 1 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Wireless Power and Data Monitoring for Implantable or Wearable Systems | Robert Puers (u. a.) | Taschenbuch | 200 S. | Englisch | 2015 | LAP LAMBERT Academic Publishing | EAN 9783659759048 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 104267750
Anzahl: 5 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -In this work developments are presented, which shift the technological frontiers in the field of powering and data communication for wearable and implantable medical systems and which may help the introduction of ambulatory monitoring and ambient intelligence in the near future. Inductive power transmission is proposed as a way to provide power to wearable and implantable electronic devices. The design trajectory of an inductive link is covered and optimization methods are proposed and successfully illustrated with an example. Next, the integration of bidirectional data transmission in the inductive link is treated. The major contribution is the use of one single inductive link for both the transmission of power and the bidirectional transmission of data. This drastically increases the ease of use of the system and decreases the dimensions of the secondary (implantable) circuit, as only on set of antennae is used. Two examples are the instrumentation of a hip prosthesis for the monitoring of early loosening in orthopaedics, and a smart suit for the monitoring of children in a hospital environment, containing dedicated textile sensors for respiration and ECG.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 200 pp. Englisch. Bestandsnummer des Verkäufers 9783659759048
Anzahl: 1 verfügbar