In this in vivo study different methods (digital tactile sensation method, Digital radiographic method, and EAL method that used Root ZX) were evaluated for the accuracy in determining the working length of the root canal. The results revealed that the digital tactile and EAL methods located the constriction as accurately as the actual root canal length obtained by locating and viewing the constriction directly. In today's technically advanced age of endodontic practice, though the digital tactile sensation is considered as an obsolete method and there are not many studies done to evaluate its accuracy, our study surprisingly revealed the results of digital tactile method as being more accurate, than even digital radiographic method, when compared to the actual length.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Dr. Jyoti Mandlik ist außerordentliche Professorin in der Abteilung für konservierende Zahnmedizin und Endodontie am Bharati Vidyapeeth Deemed University Dental College and Hospital Pune. Sie promoviert auf dem Gebiet der Endodontie. Sie hat mehr als 25 Publikationen in verschiedenen internationalen und nationalen Fachzeitschriften veröffentlicht. Sie ist außerdem Redakteurin des IIOABJ.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In this in vivo study different methods (digital tactile sensation method, Digital radiographic method, and EAL method that used Root ZX) were evaluated for the accuracy in determining the working length of the root canal. The results revealed that the digital tactile and EAL methods located the constriction as accurately as the actual root canal length obtained by locating and viewing the constriction directly. In today¿s technically advanced age of endodontic practice, though the digital tactile sensation is considered as an obsolete method and there are not many studies done to evaluate its accuracy, our study surprisingly revealed the results of digital tactile method as being more accurate, than even digital radiographic method, when compared to the actual length. 60 pp. Englisch. Bestandsnummer des Verkäufers 9783659796012
Anzahl: 2 verfügbar
Anbieter: Books Puddle, Woodside, NY, USA
Zustand: New. Bestandsnummer des Verkäufers 26396995037
Anzahl: 4 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. Print on Demand. Bestandsnummer des Verkäufers 400430594
Anzahl: 4 verfügbar
Anbieter: Biblios, Frankfurt am main, HESSE, Deutschland
Zustand: New. PRINT ON DEMAND. Bestandsnummer des Verkäufers 18396995031
Anzahl: 4 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In this in vivo study different methods (digital tactile sensation method, Digital radiographic method, and EAL method that used Root ZX) were evaluated for the accuracy in determining the working length of the root canal. The results revealed that the digital tactile and EAL methods located the constriction as accurately as the actual root canal length obtained by locating and viewing the constriction directly. In today's technically advanced age of endodontic practice, though the digital tactile sensation is considered as an obsolete method and there are not many studies done to evaluate its accuracy, our study surprisingly revealed the results of digital tactile method as being more accurate, than even digital radiographic method, when compared to the actual length. Bestandsnummer des Verkäufers 9783659796012
Anzahl: 1 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Mandlik JyotiDr. Jyoti Mandlik is Associate Professor at the Department of Conservative Dentistry and Endodontics from Bharati Vidyapeeth Deemed University Dental College and Hospital Pune. She is pursuing her Ph.D. in Endodontics. S. Bestandsnummer des Verkäufers 508968111
Anzahl: Mehr als 20 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -In this in vivo study different methods (digital tactile sensation method, Digital radiographic method, and EAL method that used Root ZX) were evaluated for the accuracy in determining the working length of the root canal. The results revealed that the digital tactile and EAL methods located the constriction as accurately as the actual root canal length obtained by locating and viewing the constriction directly. In today's technically advanced age of endodontic practice, though the digital tactile sensation is considered as an obsolete method and there are not many studies done to evaluate its accuracy, our study surprisingly revealed the results of digital tactile method as being more accurate, than even digital radiographic method, when compared to the actual length.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 60 pp. Englisch. Bestandsnummer des Verkäufers 9783659796012
Anzahl: 1 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. An In-Vivo evaluation of three methods of working length determination | Jyoti Mandlik (u. a.) | Taschenbuch | Englisch | 2017 | LAP LAMBERT Academic Publishing | EAN 9783659796012 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu Print on Demand. Bestandsnummer des Verkäufers 120559156
Anzahl: 5 verfügbar