The study of reduced graphene oxide as nanofluid with the base fluid of volume fraction (10%Vol) was prepared to perform the thermal investigation on the solar parabolic trough collector receiver model. The peak intensity of nanoparticle size distribution and crystal structure behavior was employed by transmission electronic microscopy (TEM) and X-ray diffractometer (XRD) techniques. In order to enhance the thermal performance of the receiver model between evacuated and non-evacuated conditions is established. For testing of physical parameters of Reynolds number, friction factor, and average Nusselt numbers with a fixed magnitude of heat flux at the duration of the time period. In this evacuated and non-evacuated model, the friction factor and average Nusselt number were slightly decreased for rGO/distilled water and comparatively increased for base fluids. Due to the addition of nanoparticles, the thermophysical parameters of nanofluid had thinner layers of the thermal boundary of particle size inside the fluid of pipe wall sections of evacuated receiver model are more efficient heat transfer capability compared to the non-evacuated model.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Dr. Ananda Guddenahalli Kullegowda, Professor Assistente, Departamento de Engenharia Mecânica, Faculdade de Engenharia da Universidade de Visvesvaraya, Estado de Karnataka, Índia. Adquiriu uma vasta experiência de ensino durante um período de 10 anos. Publicou mais de 15 artigos de investigação em revistas internacionais com revisão por pares.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The study of reduced graphene oxide as nanofluid with the base fluid of volume fraction (10%Vol) was prepared to perform the thermal investigation on the solar parabolic trough collector receiver model. The peak intensity of nanoparticle size distribution and crystal structure behavior was employed by transmission electronic microscopy (TEM) and X-ray diffractometer (XRD) techniques. In order to enhance the thermal performance of the receiver model between evacuated and non-evacuated conditions is established. For testing of physical parameters of Reynolds number, friction factor, and average Nusselt numbers with a fixed magnitude of heat flux at the duration of the time period. In this evacuated and non-evacuated model, the friction factor and average Nusselt number were slightly decreased for rGO/distilled water and comparatively increased for base fluids. Due to the addition of nanoparticles, the thermophysical parameters of nanofluid had thinner layers of the thermal boundary of particle size inside the fluid of pipe wall sections of evacuated receiver model are more efficient heat transfer capability compared to the non-evacuated model. 108 pp. Englisch. Bestandsnummer des Verkäufers 9783659967573
Anzahl: 2 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. The study of reduced graphene oxide as nanofluid with the base fluid of volume fraction (10%Vol) was prepared to perform the thermal investigation on the solar parabolic trough collector receiver model. The peak intensity of nanoparticle size distribution a. Bestandsnummer des Verkäufers 577224212
Anzahl: Mehr als 20 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The study of reduced graphene oxide as nanofluid with the base fluid of volume fraction (10%Vol) was prepared to perform the thermal investigation on the solar parabolic trough collector receiver model. The peak intensity of nanoparticle size distribution and crystal structure behavior was employed by transmission electronic microscopy (TEM) and X-ray diffractometer (XRD) techniques. In order to enhance the thermal performance of the receiver model between evacuated and non-evacuated conditions is established. For testing of physical parameters of Reynolds number, friction factor, and average Nusselt numbers with a fixed magnitude of heat flux at the duration of the time period. In this evacuated and non-evacuated model, the friction factor and average Nusselt number were slightly decreased for rGO/distilled water and comparatively increased for base fluids. Due to the addition of nanoparticles, the thermophysical parameters of nanofluid had thinner layers of the thermal boundary of particle size inside the fluid of pipe wall sections of evacuated receiver model are more efficient heat transfer capability compared to the non-evacuated model.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 108 pp. Englisch. Bestandsnummer des Verkäufers 9783659967573
Anzahl: 1 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The study of reduced graphene oxide as nanofluid with the base fluid of volume fraction (10%Vol) was prepared to perform the thermal investigation on the solar parabolic trough collector receiver model. The peak intensity of nanoparticle size distribution and crystal structure behavior was employed by transmission electronic microscopy (TEM) and X-ray diffractometer (XRD) techniques. In order to enhance the thermal performance of the receiver model between evacuated and non-evacuated conditions is established. For testing of physical parameters of Reynolds number, friction factor, and average Nusselt numbers with a fixed magnitude of heat flux at the duration of the time period. In this evacuated and non-evacuated model, the friction factor and average Nusselt number were slightly decreased for rGO/distilled water and comparatively increased for base fluids. Due to the addition of nanoparticles, the thermophysical parameters of nanofluid had thinner layers of the thermal boundary of particle size inside the fluid of pipe wall sections of evacuated receiver model are more efficient heat transfer capability compared to the non-evacuated model. Bestandsnummer des Verkäufers 9783659967573
Anzahl: 1 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Nanofluids Processing on Solar Water Heating Systems | Solar Energy Conversion | Ananda G K (u. a.) | Taschenbuch | Englisch | 2022 | LAP LAMBERT Academic Publishing | EAN 9783659967573 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 121380729
Anzahl: 5 verfügbar