Master's Thesis from the year 2017 in the subject Engineering - Mechanical Engineering, grade: 4.00, Kathmandu University (School of Engineering), course: Planning and Operation of Energy System, language: English, abstract: In power system, research area is widening and one is Distributed Generation (DG) integration in a distribution system. It restructures the power system and also helps in distribution system planning. This dissertation addresses the issue of voltage margin improvement by integrating DG unit and, therefore, this dissertation presents the model to enhance the candidate bus voltage of distribution system by optimal integration of DG units. The technical analysis is performed for radial distribution system (RDS). The proposed algorithm evaluates the base condition of loss and bus voltage and then generate populations of solutions at first stage. Optimization of DG unit size and locate the optimal bus can be done with the particle swarm optimization (PSO) method. The proposed paradigm works with the objective that minimize the active power loss under a constraint of voltage limit and DG size limit. Finally, the conclusion is that DG unit can locate optimally with optimized size to the distribution system for the voltage profile improvement of the buses and also the total loss of system is reduced. It is also concluded that the model can be used for any radial distribution systems.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: California Books, Miami, FL, USA
Zustand: New. Bestandsnummer des Verkäufers I-9783668551015
Anzahl: Mehr als 20 verfügbar
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Master's Thesis from the year 2017 in the subject Engineering - Mechanical Engineering, grade: 4.00, Kathmandu University (School of Engineering), course: Planning and Operation of Energy System, language: English, abstract: In power system, research area is widening and one is Distributed Generation (DG) integration in a distribution system. It restructures the power system and also helps in distribution system planning. This dissertation addresses the issue of voltage margin improvement by integrating DG unit and, therefore, this dissertation presents the model to enhance the candidate bus voltage of distribution system by optimal integration of DG units. The technical analysis is performed for radial distribution system (RDS). The proposed algorithm evaluates the base condition of loss and bus voltage and then generate populations of solutions at first stage. Optimization of DG unit size and locate the optimal bus can be done with the particle swarm optimization (PSO) method. The proposed paradigm works with the objective that minimize the active power loss under a constraint of voltage limit and DG size limit. Finally, the conclusion is that DG unit can locate optimally with optimized size to the distribution system for the voltage profile improvement of the buses and also the total loss of system is reduced. It is also concluded that the model can be used for any radial distribution systems. 140 pp. Englisch. Bestandsnummer des Verkäufers 9783668551015
Anzahl: 2 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Master's Thesis from the year 2017 in the subject Engineering - Mechanical Engineering, grade: 4.00, Kathmandu University (School of Engineering), course: Planning and Operation of Energy System, language: English, abstract: In power system, research area is widening and one is Distributed Generation (DG) integration in a distribution system. It restructures the power system and also helps in distribution system planning. This dissertation addresses the issue of voltage margin improvement by integrating DG unit and, therefore, this dissertation presents the model to enhance the candidate bus voltage of distribution system by optimal integration of DG units. The technical analysis is performed for radial distribution system (RDS). The proposed algorithm evaluates the base condition of loss and bus voltage and then generate populations of solutions at first stage. Optimization of DG unit size and locate the optimal bus can be done with the particle swarm optimization (PSO) method. The proposed paradigm works with the objective that minimize the active power loss under a constraint of voltage limit and DG size limit. Finally, the conclusion is that DG unit can locate optimally with optimized size to the distribution system for the voltage profile improvement of the buses and also the total loss of system is reduced. It is also concluded that the model can be used for any radial distribution systems.Books on Demand GmbH, Überseering 33, 22297 Hamburg 140 pp. Englisch. Bestandsnummer des Verkäufers 9783668551015
Anzahl: 1 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. Druck auf Anfrage Neuware - Printed after ordering - Master's Thesis from the year 2017 in the subject Engineering - Mechanical Engineering, grade: 4.00, Kathmandu University (School of Engineering), course: Planning and Operation of Energy System, language: English, abstract: In power system, research area is widening and one is Distributed Generation (DG) integration in a distribution system. It restructures the power system and also helps in distribution system planning. This dissertation addresses the issue of voltage margin improvement by integrating DG unit and, therefore, this dissertation presents the model to enhance the candidate bus voltage of distribution system by optimal integration of DG units. The technical analysis is performed for radial distribution system (RDS). The proposed algorithm evaluates the base condition of loss and bus voltage and then generate populations of solutions at first stage. Optimization of DG unit size and locate the optimal bus can be done with the particle swarm optimization (PSO) method. The proposed paradigm works with the objective that minimize the active power loss under a constraint of voltage limit and DG size limit. Finally, the conclusion is that DG unit can locate optimally with optimized size to the distribution system for the voltage profile improvement of the buses and also the total loss of system is reduced. It is also concluded that the model can be used for any radial distribution systems. Bestandsnummer des Verkäufers 9783668551015
Anzahl: 1 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Particle Swarm Optimization Approach for Distributed Generation Planning to Improve the Voltage Profile Margin | Ajay Singh | Taschenbuch | 140 S. | Englisch | 2017 | GRIN Verlag | EAN 9783668551015 | Verantwortliche Person für die EU: GRIN Publishing GmbH, Waltherstr. 23, 80337 München, info[at]grin[dot]com | Anbieter: preigu. Bestandsnummer des Verkäufers 110086983
Anzahl: 5 verfügbar