This book concerns the development of accurate modelling of geometric detection efficiencies, photon attenuation and scatter in 3D whole body positron emission tomography (PET). In particular, large patient studies are considered where a vast majority of emitted photon pairs from around the centre of the patient is scattered and therefore attenuated from the original (true) photon trajectories. Central to this work is modelling of the scatter component by the means of a scatter transfer matrix. The matrix describes the detection of scatter events in every line of response (LOR) in terms of absolute probabilities for every individual voxel. However, to utilise the full potential of the scatter model, the true component modelling is also based on the calculation of absolute photon detection probabilities, thus allowing unification of photon scatter and attenuation.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Pawel Markiewicz is a postdoctoral research associate in PET imaging, based in Wolfson Molecular Imaging Centre, University of Manchester, UK. Dr Andrew Reader is a Canada Research Chair in PET imaging, based at the McConnell Brain Imaging Centre, part of the Montreal Neurological Institute and McGill University in Canada.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book concerns the development of accurate modelling of geometric detection efficiencies, photon attenuation and scatter in 3D whole body positron emission tomography (PET). In particular, large patient studies are considered where a vast majority of emitted photon pairs from around the centre of the patient is scattered and therefore attenuated from the original (true) photon trajectories. Central to this work is modelling of the scatter component by the means of a scatter transfer matrix. The matrix describes the detection of scatter events in every line of response (LOR) in terms of absolute probabilities for every individual voxel. However, to utilise the full potential of the scatter model, the true component modelling is also based on the calculation of absolute photon detection probabilities, thus allowing unification of photon scatter and attenuation. 192 pp. Englisch. Bestandsnummer des Verkäufers 9783838345284
Anzahl: 2 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Markiewicz PawelPawel Markiewicz is a postdoctoral research associate in PET imaging, based in Wolfson Molecular Imaging Centre, University of Manchester, UK. Dr Andrew Reader is a Canada Research Chair in PET imaging, based at th. Bestandsnummer des Verkäufers 5414980
Anzahl: Mehr als 20 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. System Modelling For 3D Whole Body Positron Emission Tomography | An Approach To Unified System Modelling Of Scatter And Attenuation | Pawel Markiewicz (u. a.) | Taschenbuch | 192 S. | Englisch | 2010 | LAP LAMBERT Academic Publishing | EAN 9783838345284 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 101217046
Anzahl: 5 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book concerns the development of accurate modelling of geometric detection efficiencies, photon attenuation and scatter in 3D whole body positron emission tomography (PET). In particular, large patient studies are considered where a vast majority of emitted photon pairs from around the centre of the patient is scattered and therefore attenuated from the original (true) photon trajectories. Central to this work is modelling of the scatter component by the means of a scatter transfer matrix. The matrix describes the detection of scatter events in every line of response (LOR) in terms of absolute probabilities for every individual voxel. However, to utilise the full potential of the scatter model, the true component modelling is also based on the calculation of absolute photon detection probabilities, thus allowing unification of photon scatter and attenuation.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 192 pp. Englisch. Bestandsnummer des Verkäufers 9783838345284
Anzahl: 1 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book concerns the development of accurate modelling of geometric detection efficiencies, photon attenuation and scatter in 3D whole body positron emission tomography (PET). In particular, large patient studies are considered where a vast majority of emitted photon pairs from around the centre of the patient is scattered and therefore attenuated from the original (true) photon trajectories. Central to this work is modelling of the scatter component by the means of a scatter transfer matrix. The matrix describes the detection of scatter events in every line of response (LOR) in terms of absolute probabilities for every individual voxel. However, to utilise the full potential of the scatter model, the true component modelling is also based on the calculation of absolute photon detection probabilities, thus allowing unification of photon scatter and attenuation. Bestandsnummer des Verkäufers 9783838345284
Anzahl: 1 verfügbar
Anbieter: Mispah books, Redhill, SURRE, Vereinigtes Königreich
Paperback. Zustand: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Bestandsnummer des Verkäufers ERICA79038383452826
Anzahl: 1 verfügbar