Many methods are used for measuring and defining the presence of Parkinson's disease. One important aspect of the disease is gait disturbance, which can be discovered in the early stages of the disease. This disturbance can be measured using three dimensional accelerometers, which are present in the Shimmer device. These devices are light weighted wireless sensor nodes which can be easily mounted on the patient's limbs. Data captured by the device can be streamed to a computer for real-time processing. The Matlab algorithms for step detection are converted to C++ code so they can be used in the EyesWeb environment. Whereas Matlab code can only serve post-processing, the Shimmer's Bluetooth datastream can now be processed in real-time, since the EyesWeb environment supports real-time execution. Hence the Visual Studio environment is needed to design the algorithms into C++ based EyesWeb blocks. This real-time detection algorithm can be applied easily in small and inexpensive lab environments to calculate and obtain the Parkinson's disease severity parameters. Hereby conclusions can be made to prevent the progress of the disease and to treat Parkinson's disorder in early stages.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Wouter and Jonas were both students industrial engineering, Wouter with emphasis on IT and Jonas on Electronics. They graduated with distinction. Three and a half years of this education was performed in their home university in Ghent (Belgium). This master's thesis was written in Karlskrona (Sweden) on an abroad student program for half a year.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Many methods are used for measuring and defining the presence of Parkinson's disease. One important aspect of the disease is gait disturbance, which can be discovered in the early stages of the disease. This disturbance can be measured using three dimensional accelerometers, which are present in the Shimmer device. These devices are light weighted wireless sensor nodes which can be easily mounted on the patient's limbs. Data captured by the device can be streamed to a computer for real-time processing. The Matlab algorithms for step detection are converted to C++ code so they can be used in the EyesWeb environment. Whereas Matlab code can only serve post-processing, the Shimmer's Bluetooth datastream can now be processed in real-time, since the EyesWeb environment supports real-time execution. Hence the Visual Studio environment is needed to design the algorithms into C++ based EyesWeb blocks. This real-time detection algorithm can be applied easily in small and inexpensive lab environments to calculate and obtain the Parkinson's disease severity parameters. Hereby conclusions can be made to prevent the progress of the disease and to treat Parkinson's disorder in early stages. 96 pp. Englisch. Bestandsnummer des Verkäufers 9783846591673
Anzahl: 2 verfügbar
Anbieter: Books Puddle, New York, NY, USA
Zustand: New. pp. 96. Bestandsnummer des Verkäufers 2698160961
Anzahl: 4 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. Print on Demand pp. 96 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam. Bestandsnummer des Verkäufers 95317662
Anzahl: 4 verfügbar
Anbieter: Biblios, Frankfurt am main, HESSE, Deutschland
Zustand: New. PRINT ON DEMAND pp. 96. Bestandsnummer des Verkäufers 1898160971
Anzahl: 4 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Speybrouck WouterWouter and Jonas were both students industrial engineering, Wouter with emphasis on IT and Jonas on Electronics. They graduated with distinction. Three and a half years of this education was performed in their home u. Bestandsnummer des Verkäufers 5501780
Anzahl: Mehr als 20 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Many methods are used for measuring and defining the presence of Parkinson's disease. One important aspect of the disease is gait disturbance, which can be discovered in the early stages of the disease. This disturbance can be measured using three dimensional accelerometers, which are present in the Shimmer device. These devices are light weighted wireless sensor nodes which can be easily mounted on the patient's limbs. Data captured by the device can be streamed to a computer for real-time processing. The Matlab algorithms for step detection are converted to C++ code so they can be used in the EyesWeb environment. Whereas Matlab code can only serve post-processing, the Shimmer's Bluetooth datastream can now be processed in real-time, since the EyesWeb environment supports real-time execution. Hence the Visual Studio environment is needed to design the algorithms into C++ based EyesWeb blocks. This real-time detection algorithm can be applied easily in small and inexpensive lab environments to calculate and obtain the Parkinson's disease severity parameters. Hereby conclusions can be made to prevent the progress of the disease and to treat Parkinson's disorder in early stages.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 96 pp. Englisch. Bestandsnummer des Verkäufers 9783846591673
Anzahl: 1 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Many methods are used for measuring and defining the presence of Parkinson's disease. One important aspect of the disease is gait disturbance, which can be discovered in the early stages of the disease. This disturbance can be measured using three dimensional accelerometers, which are present in the Shimmer device. These devices are light weighted wireless sensor nodes which can be easily mounted on the patient's limbs. Data captured by the device can be streamed to a computer for real-time processing. The Matlab algorithms for step detection are converted to C++ code so they can be used in the EyesWeb environment. Whereas Matlab code can only serve post-processing, the Shimmer's Bluetooth datastream can now be processed in real-time, since the EyesWeb environment supports real-time execution. Hence the Visual Studio environment is needed to design the algorithms into C++ based EyesWeb blocks. This real-time detection algorithm can be applied easily in small and inexpensive lab environments to calculate and obtain the Parkinson's disease severity parameters. Hereby conclusions can be made to prevent the progress of the disease and to treat Parkinson's disorder in early stages. Bestandsnummer des Verkäufers 9783846591673
Anzahl: 1 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Implementing real-time step detection algorithm in EyesWeb environment | Monitoring the gait of Parkinson's patients | Wouter Speybrouck (u. a.) | Taschenbuch | 96 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783846591673 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 106671828
Anzahl: 5 verfügbar