The protection of the irrigation pipeline networks against Water Hammer -as a result of pump power failure- is of great importance. In this study, an improved design for irrigation pipeline networks is investigated.Basic partial differential equations based on one-dimensional homogenous flow model are formulated and solved by the method of characteristics. The differential equations of momentum and continuity are developed for solving transient problem. For transient condition caused by pump failure, four different scenarios were considered to study the impact of column separation of the pipelines system. These scenarios are the steady state condition, transient condition without protection, transient condition with air vessel as a protection and transient condition with air vessel and two surge towers as a protection. Also, the impact of changing diameter and wall thickness of pipes, changing material type and polar moment of inertia of the pump on the magnitude of the maximum pressure heads and column separation were included in the study. The Water Hammer Software "Wanda V3.30" was applied and the results were graphically presented for different relationships.
A Professor at the Civil Engineering Department, Faculty of Engineering, Shobra, Banha University, Cairo, Egypt. He holds a B.Sc., M.Sc., and Ph.D. in Civil Engineering and Business Administration studies from Ain Shams University, Cairo, Egypt, Texas A&M, and Harvard Universities, U.S.A. He is also a member of the ASCE, IAHR, COPRI, and EWRI.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
EUR 23,00 für den Versand von Deutschland nach USA
Versandziele, Kosten & DauerAnbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The protection of the irrigation pipeline networks against Water Hammer -as a result of pump power failure- is of great importance. In this study, an improved design for irrigation pipeline networks is investigated.Basic partial differential equations based on one-dimensional homogenous flow model are formulated and solved by the method of characteristics. The differential equations of momentum and continuity are developed for solving transient problem. For transient condition caused by pump failure, four different scenarios were considered to study the impact of column separation of the pipelines system. These scenarios are the steady state condition, transient condition without protection, transient condition with air vessel as a protection and transient condition with air vessel and two surge towers as a protection. Also, the impact of changing diameter and wall thickness of pipes, changing material type and polar moment of inertia of the pump on the magnitude of the maximum pressure heads and column separation were included in the study. The Water Hammer Software 'Wanda V3.30' was applied and the results were graphically presented for different relationships. 184 pp. Englisch. Bestandsnummer des Verkäufers 9783847314073
Anzahl: 2 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The protection of the irrigation pipeline networks against Water Hammer -as a result of pump power failure- is of great importance. In this study, an improved design for irrigation pipeline networks is investigated.Basic partial differential equations based on one-dimensional homogenous flow model are formulated and solved by the method of characteristics. The differential equations of momentum and continuity are developed for solving transient problem. For transient condition caused by pump failure, four different scenarios were considered to study the impact of column separation of the pipelines system. These scenarios are the steady state condition, transient condition without protection, transient condition with air vessel as a protection and transient condition with air vessel and two surge towers as a protection. Also, the impact of changing diameter and wall thickness of pipes, changing material type and polar moment of inertia of the pump on the magnitude of the maximum pressure heads and column separation were included in the study. The Water Hammer Software 'Wanda V3.30' was applied and the results were graphically presented for different relationships. Bestandsnummer des Verkäufers 9783847314073
Anzahl: 1 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Elsaeed GamalA Professor at the Civil Engineering Department, Faculty of Engineering, Shobra, Banha University, Cairo, Egypt. He holds a B.Sc., M.Sc., and Ph.D. in Civil Engineering and Business Administration studies from Ain Shams . Bestandsnummer des Verkäufers 5509413
Anzahl: Mehr als 20 verfügbar