Parallel manipulator is ideal for jobs like, robotic surgery, flight simulation, precise manufacturing and 3D-printing but precise part, or tool, positioning on parallel manipulator is a challenging task. With errors in position, one can never achieve the required quality of the part. In this work, main focus is to find out positioning errors of a hexapod platform - during machining. Legs are elastic while the platform, part and leg-platform contacts are rigid bodies. All legs are assumed to be 3D massless elastic trusses. When machining load is applied on the part placed on the platform, the position of platform may change due to elasticity. Lagrange formulation is used to calculate the positioning error of the platform, as a result of machining forces and torques. A generalized algorithm is established, using Mathematica®, which gives the positioning error of “n” legged system with any initial orientation of the platform. In the second part, Natural frequencies are calculated. The proposed methodology is applied on Physik Instrumente's H-840 Hexapod. The Hexapod is designed and modelled in CATIA® and results are validated with FE Analysis, as well as, from the literature.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Muhammad Sohail, MS (Engg): Studied Mechanical Engineering at National University of Sciences and Technology, Pakistan. Lecturer at NUST, Military College of Engineering, Risalpur.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Parallel manipulator is ideal for jobs like, robotic surgery, flight simulation, precise manufacturing and 3D-printing but precise part, or tool, positioning on parallel manipulator is a challenging task. With errors in position, one can never achieve the required quality of the part. In this work, main focus is to find out positioning errors of a hexapod platform - during machining. Legs are elastic while the platform, part and leg-platform contacts are rigid bodies. All legs are assumed to be 3D massless elastic trusses. When machining load is applied on the part placed on the platform, the position of platform may change due to elasticity. Lagrange formulation is used to calculate the positioning error of the platform, as a result of machining forces and torques. A generalized algorithm is established, using Mathematica®, which gives the positioning error of 'n' legged system with any initial orientation of the platform. In the second part, Natural frequencies are calculated. The proposed methodology is applied on Physik Instrumente's H-840 Hexapod. The Hexapod is designed and modelled in CATIA® and results are validated with FE Analysis, as well as, from the literature. 84 pp. Englisch. Bestandsnummer des Verkäufers 9786139871568
Anzahl: 2 verfügbar
Anbieter: Revaluation Books, Exeter, Vereinigtes Königreich
Paperback. Zustand: Brand New. 84 pages. 8.66x5.91x0.19 inches. In Stock. Bestandsnummer des Verkäufers zk6139871565
Anzahl: 1 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Sohail MuhammadMuhammad Sohail, MS (Engg): Studied Mechanical Engineering at National University of Sciences and Technology, Pakistan. Lecturer at NUST, Military College of Engineering, Risalpur.Parallel manipulator is ideal for . Bestandsnummer des Verkäufers 385875135
Anzahl: Mehr als 20 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Parallel manipulator is ideal for jobs like, robotic surgery, flight simulation, precise manufacturing and 3D-printing but precise part, or tool, positioning on parallel manipulator is a challenging task. With errors in position, one can never achieve the required quality of the part. In this work, main focus is to find out positioning errors of a hexapod platform - during machining. Legs are elastic while the platform, part and leg-platform contacts are rigid bodies. All legs are assumed to be 3D massless elastic trusses. When machining load is applied on the part placed on the platform, the position of platform may change due to elasticity. Lagrange formulation is used to calculate the positioning error of the platform, as a result of machining forces and torques. A generalized algorithm is established, using Mathematica®, which gives the positioning error of 'n' legged system with any initial orientation of the platform. In the second part, Natural frequencies are calculated. The proposed methodology is applied on Physik Instrumente's H-840 Hexapod. The Hexapod is designed and modelled in CATIA® and results are validated with FE Analysis, as well as, from the literature.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 84 pp. Englisch. Bestandsnummer des Verkäufers 9786139871568
Anzahl: 1 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Parallel manipulator is ideal for jobs like, robotic surgery, flight simulation, precise manufacturing and 3D-printing but precise part, or tool, positioning on parallel manipulator is a challenging task. With errors in position, one can never achieve the required quality of the part. In this work, main focus is to find out positioning errors of a hexapod platform - during machining. Legs are elastic while the platform, part and leg-platform contacts are rigid bodies. All legs are assumed to be 3D massless elastic trusses. When machining load is applied on the part placed on the platform, the position of platform may change due to elasticity. Lagrange formulation is used to calculate the positioning error of the platform, as a result of machining forces and torques. A generalized algorithm is established, using Mathematica®, which gives the positioning error of 'n' legged system with any initial orientation of the platform. In the second part, Natural frequencies are calculated. The proposed methodology is applied on Physik Instrumente's H-840 Hexapod. The Hexapod is designed and modelled in CATIA® and results are validated with FE Analysis, as well as, from the literature. Bestandsnummer des Verkäufers 9786139871568
Anzahl: 1 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Positioning Errors in Parallel Manipulator | Application of Lagrangian Formulation to study 6DoF positioning errors and Eigen values/vector of "n" legged manipulator | Muhammad Sohail (u. a.) | Taschenbuch | 84 S. | Englisch | 2018 | LAP LAMBERT Academic Publishing | EAN 9786139871568 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 114219378
Anzahl: 5 verfügbar