The Type-4 wind generation system integrated to Micro-grid through VSC-HVDC link is implemented and the analysis is done by considering a fault on the grid side by the system gets isolated and wind generation system transfers voltage to local load and remote load. When a DC fault is occurred on the VSC-HVDC link then the grid side breaker and wind side breaker gets open, then system gets isolated. The present system considers the“Fault Ride Through” (FRT) conditions, According to the Indian grid code of contact wind generation maintain constant even the voltage collapse is occurred on the grid side. The VSC-HVDC based Type-4 Wind Generation System give more reliable to operate under FRT condition and can meet the Emergency Load demand when the system is under fault condition.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
1st author received the B.Tech degree in Electrical Engg. from Nagarjuna University in 2008, received M.Tech degree in Power System Engineering from JNTU, Kakinada in year 2012. Since May 2014 working as an Assistant Professor at V R Siddhartha Engineering College. He worked as Testing & Commissioning Engg. in L&T Construction, Chennai Division.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The Type-4 wind generation system integrated to Micro-grid through VSC-HVDC link is implemented and the analysis is done by considering a fault on the grid side by the system gets isolated and wind generation system transfers voltage to local load and remote load. When a DC fault is occurred on the VSC-HVDC link then the grid side breaker and wind side breaker gets open, then system gets isolated. The present system considers the'Fault Ride Through' (FRT) conditions, According to the Indian grid code of contact wind generation maintain constant even the voltage collapse is occurred on the grid side. The VSC-HVDC based Type-4 Wind Generation System give more reliable to operate under FRT condition and can meet the Emergency Load demand when the system is under fault condition. 92 pp. Englisch. Bestandsnummer des Verkäufers 9786139887606
Anzahl: 2 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Ch. S. V. S. Phani Kumar1st author received the B.Tech degree in Electrical Engg. from Nagarjuna University in 2008, received M.Tech degree in Power System Engineering from JNTU, Kakinada in year 2012. Since May 2014 working as an As. Bestandsnummer des Verkäufers 385875928
Anzahl: Mehr als 20 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The Type-4 wind generation system integrated to Micro-grid through VSC-HVDC link is implemented and the analysis is done by considering a fault on the grid side by the system gets isolated and wind generation system transfers voltage to local load and remote load. When a DC fault is occurred on the VSC-HVDC link then the grid side breaker and wind side breaker gets open, then system gets isolated. The present system considers the'Fault Ride Through' (FRT) conditions, According to the Indian grid code of contact wind generation maintain constant even the voltage collapse is occurred on the grid side. The VSC-HVDC based Type-4 Wind Generation System give more reliable to operate under FRT condition and can meet the Emergency Load demand when the system is under fault condition.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 92 pp. Englisch. Bestandsnummer des Verkäufers 9786139887606
Anzahl: 1 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The Type-4 wind generation system integrated to Micro-grid through VSC-HVDC link is implemented and the analysis is done by considering a fault on the grid side by the system gets isolated and wind generation system transfers voltage to local load and remote load. When a DC fault is occurred on the VSC-HVDC link then the grid side breaker and wind side breaker gets open, then system gets isolated. The present system considers the'Fault Ride Through' (FRT) conditions, According to the Indian grid code of contact wind generation maintain constant even the voltage collapse is occurred on the grid side. The VSC-HVDC based Type-4 Wind Generation System give more reliable to operate under FRT condition and can meet the Emergency Load demand when the system is under fault condition. Bestandsnummer des Verkäufers 9786139887606
Anzahl: 1 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. LVRT and Stability Analysis of WGS Integrated to Microgrid | S. V. S. Phani Kumar Ch. (u. a.) | Taschenbuch | 92 S. | Englisch | 2018 | LAP LAMBERT Academic Publishing | EAN 9786139887606 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 114327402
Anzahl: 5 verfügbar