Increased uses of nonlinear loads, encouragement to use distributed generations at the consumer premises make the power system fail to sustain quality of the supply. Due to this supply voltage and current becomes distorted and contain harmonics which is not good for machineries and applications used by industry, domestic and residential consumers. Among the different configurations of filters such as series, shunt and hybrid, shunt active power filter is considered in this research work. The actual behaviour of shunt active power filter lies with the proper control strategy. It is expected that the control strategy should take care of harmonic mitigation and power factor improvement with less complexity in controller implementation. Moreover the available control strategy takes care of mostly current harmonics and rarely in voltage harmonics. Furthermore only few research contributions have been made to mitigate the voltage harmonics in addition to current harmonics. A MATLAB model has been developed to simulate the system operation by considering different control schemes and simulation have been carried out and results are obtained under steady state and dynamic conditions.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: moluna, Greven, Deutschland
Zustand: New. Bestandsnummer des Verkäufers 327230930
Anzahl: Mehr als 20 verfügbar
Anbieter: Books Puddle, New York, NY, USA
Zustand: New. Bestandsnummer des Verkäufers 26386672944
Anzahl: 4 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. Print on Demand. Bestandsnummer des Verkäufers 393975535
Anzahl: 4 verfügbar
Anbieter: Biblios, Frankfurt am main, HESSE, Deutschland
Zustand: New. PRINT ON DEMAND. Bestandsnummer des Verkäufers 18386672954
Anzahl: 4 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Harmonics mitigation in distributed generation system | Performance investigation | Muhaidheen M. (u. a.) | Taschenbuch | Englisch | LAP Lambert Academic Publishing | EAN 9786200433794 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 117578844
Anzahl: 5 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Increased uses of nonlinear loads, encouragement to use distributed generations at the consumer premises make the power system fail to sustain quality of the supply. Due to this supply voltage and current becomes distorted and contain harmonics which is not good for machineries and applications used by industry, domestic and residential consumers. Among the different configurations of filters such as series, shunt and hybrid, shunt active power filter is considered in this research work. The actual behaviour of shunt active power filter lies with the proper control strategy. It is expected that the control strategy should take care of harmonic mitigation and power factor improvement with less complexity in controller implementation. Moreover the available control strategy takes care of mostly current harmonics and rarely in voltage harmonics. Furthermore only few research contributions have been made to mitigate the voltage harmonics in addition to current harmonics. A MATLAB model has been developed to simulate the system operation by considering different control schemes and simulation have been carried out and results are obtained under steady state and dynamic conditions. Bestandsnummer des Verkäufers 9786200433794
Anzahl: 2 verfügbar
Anbieter: Mispah books, Redhill, SURRE, Vereinigtes Königreich
paperback. Zustand: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Bestandsnummer des Verkäufers ERICA82962004337986
Anzahl: 1 verfügbar