To shorten the duration and cost of construction, identifying the number of floors supported by scaffolds is necessary to construct a multi-story building with the floors of long-span open-web sandwich slab. This study proposes a favorable method of two-stage construction support floors, the stages I and II, by establishing their finite element models that consider the effect of the horizontal tube constraining the upright tube in scaffolds. In addition, comparison of the two modeling results with field-measured data shows that for an open-web sandwich floor slab whose span is ¿24.00m, only the full-hall supports of the floor can be retained if its lower floor is the basement roof; otherwise, the full-hall supports should be retained both on this floor and its lower one. When the span of the floor slab is 39.00m and if the span of the lower two floors slab is ¿24.00m, reaching the concrete design strength, then the full-hall supports should be retained on this floor and the lower floor, and partial re-supports should be applied to the second lower floor.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Bo Shen (1970- ), male, Ph.D.(from Tongji University), PostDoctor(from Hunan University), Doctoral Supervisor, Professor of Structural Engineering, Mainly engaged in civil engineering structure research, Space Structures Research Center, Guizhou University, Guiyang, Guizhou.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -To shorten the duration and cost of construction, identifying the number of floors supported by scaffolds is necessary to construct a multi-story building with the floors of long-span open-web sandwich slab. This study proposes a favorable method of two-stage construction support floors, the stages I and II, by establishing their finite element models that consider the effect of the horizontal tube constraining the upright tube in scaffolds. In addition, comparison of the two modeling results with field-measured data shows that for an open-web sandwich floor slab whose span is ¿24.00m, only the full-hall supports of the floor can be retained if its lower floor is the basement roof; otherwise, the full-hall supports should be retained both on this floor and its lower one. When the span of the floor slab is 39.00m and if the span of the lower two floors slab is ¿24.00m, reaching the concrete design strength, then the full-hall supports should be retained on this floor and the lower floor, and partial re-supports should be applied to the second lower floor. 52 pp. Englisch. Bestandsnummer des Verkäufers 9786200471352
Anzahl: 2 verfügbar
Anbieter: Books Puddle, Woodside, NY, USA
Zustand: New. Bestandsnummer des Verkäufers 26397284259
Anzahl: 4 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. Print on Demand. Bestandsnummer des Verkäufers 400141436
Anzahl: 4 verfügbar
Anbieter: Biblios, Frankfurt am main, HESSE, Deutschland
Zustand: New. PRINT ON DEMAND. Bestandsnummer des Verkäufers 18397284265
Anzahl: 4 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - To shorten the duration and cost of construction, identifying the number of floors supported by scaffolds is necessary to construct a multi-story building with the floors of long-span open-web sandwich slab. This study proposes a favorable method of two-stage construction support floors, the stages I and II, by establishing their finite element models that consider the effect of the horizontal tube constraining the upright tube in scaffolds. In addition, comparison of the two modeling results with field-measured data shows that for an open-web sandwich floor slab whose span is ¿24.00m, only the full-hall supports of the floor can be retained if its lower floor is the basement roof; otherwise, the full-hall supports should be retained both on this floor and its lower one. When the span of the floor slab is 39.00m and if the span of the lower two floors slab is ¿24.00m, reaching the concrete design strength, then the full-hall supports should be retained on this floor and the lower floor, and partial re-supports should be applied to the second lower floor. Bestandsnummer des Verkäufers 9786200471352
Anzahl: 1 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Wang HuiBo Shen (1970- ), male, Ph.D.(from Tongji University), PostDoctor(from Hunan University), Doctoral Supervisor, Professor of Structural Engineering, Mainly engaged in civil engineering structure research, Space Structures Rese. Bestandsnummer des Verkäufers 497105536
Anzahl: Mehr als 20 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -To shorten the duration and cost of construction, identifying the number of floors supported by scaffolds is necessary to construct a multi-story building with the floors of long-span open-web sandwich slab. This study proposes a favorable method of two-stage construction support floors, the stages I and II, by establishing their finite element models that consider the effect of the horizontal tube constraining the upright tube in scaffolds. In addition, comparison of the two modeling results with field-measured data shows that for an open-web sandwich floor slab whose span is ¿24.00m, only the full-hall supports of the floor can be retained if its lower floor is the basement roof; otherwise, the full-hall supports should be retained both on this floor and its lower one. When the span of the floor slab is 39.00m and if the span of the lower two floors slab is ¿24.00m, reaching the concrete design strength, then the full-hall supports should be retained on this floor and the lower floor, and partial re-supports should be applied to the second lower floor.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 52 pp. Englisch. Bestandsnummer des Verkäufers 9786200471352
Anzahl: 1 verfügbar