This book covers the performance analysis of solar thermal cooling system for a computer lab situated in Government Engineering College Bharatpur using Flat Plate Collector, Evacuated Tube Collector and Compound Parabolic Collector. The computer lab has the floor and roof area 198.55 m2 .The peak cooling load is calculated and it is 34.940 kW, accordingly 10TR vapor absorption cooling system was adopted. The 10 TR vapour absorption system was operated by a field of collector area varying from 80-120 m2..The other parameters like hot storage tank, cold storage tank, pump, cooling tower etc are used. The simulation was carried out on TRANSOL Program for Bharatpur city situated in east of Rajasthan (INDIA. Sensitivity analysis shows that in coming future the as the total investment cost decreases and electricity prices increases, the payback period came down. If the total investment fall down to its 50% and electric prices are hike 50% than the payback period came down within the system life.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Khagendra Kumar Upman is working as a Assistant Professor in AIETM Jaipur. He has done M.Tech and B.Tech from RTU Kota.Happa Khan is working as a Assistant Professor in AIETM Jaipur. He has completed his M.Tech and B.Tech from RTU Kota.Dr. B.L.Gupta is working as a Asst. Professor in GEC Bharatpur. He has completed his Ph.D from MNIT Jaipur, India.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book covers the performance analysis of solar thermal cooling system for a computer lab situated in Government Engineering College Bharatpur using Flat Plate Collector, Evacuated Tube Collector and Compound Parabolic Collector. The computer lab has the floor and roof area 198.55 m2 .The peak cooling load is calculated and it is 34.940 kW, accordingly 10TR vapor absorption cooling system was adopted. The 10 TR vapour absorption system was operated by a field of collector area varying from 80-120 m2.The other parameters like hot storage tank, cold storage tank, pump, cooling tower etc are used. The simulation was carried out on TRANSOL Program for Bharatpur city situated in east of Rajasthan (INDIA. Sensitivity analysis shows that in coming future the as the total investment cost decreases and electricity prices increases, the payback period came down. If the total investment fall down to its 50% and electric prices are hike 50% than the payback period came down within the system life. 92 pp. Englisch. Bestandsnummer des Verkäufers 9786202681193
Anzahl: 2 verfügbar
Anbieter: Books Puddle, New York, NY, USA
Zustand: New. Bestandsnummer des Verkäufers 26405916325
Anzahl: 4 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. Print on Demand. Bestandsnummer des Verkäufers 407270778
Anzahl: 4 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Upman Khagendra KumarKhagendra Kumar Upman is working as a Assistant Professor in AIETM Jaipur. He has done M.Tech and B.Tech from RTU Kota.Happa Khan is working as a Assistant Professor in AIETM Jaipur. He has completed his M.Tech a. Bestandsnummer des Verkäufers 494421960
Anzahl: Mehr als 20 verfügbar
Anbieter: Biblios, Frankfurt am main, HESSE, Deutschland
Zustand: New. PRINT ON DEMAND. Bestandsnummer des Verkäufers 18405916335
Anzahl: 4 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book covers the performance analysis of solar thermal cooling system for a computer lab situated in Government Engineering College Bharatpur using Flat Plate Collector, Evacuated Tube Collector and Compound Parabolic Collector. The computer lab has the floor and roof area 198.55 m2 .The peak cooling load is calculated and it is 34.940 kW, accordingly 10TR vapor absorption cooling system was adopted. The 10 TR vapour absorption system was operated by a field of collector area varying from 80-120 m2.The other parameters like hot storage tank, cold storage tank, pump, cooling tower etc are used. The simulation was carried out on TRANSOL Program for Bharatpur city situated in east of Rajasthan (INDIA. Sensitivity analysis shows that in coming future the as the total investment cost decreases and electricity prices increases, the payback period came down. If the total investment fall down to its 50% and electric prices are hike 50% than the payback period came down within the system life.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 92 pp. Englisch. Bestandsnummer des Verkäufers 9786202681193
Anzahl: 1 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book covers the performance analysis of solar thermal cooling system for a computer lab situated in Government Engineering College Bharatpur using Flat Plate Collector, Evacuated Tube Collector and Compound Parabolic Collector. The computer lab has the floor and roof area 198.55 m2 .The peak cooling load is calculated and it is 34.940 kW, accordingly 10TR vapor absorption cooling system was adopted. The 10 TR vapour absorption system was operated by a field of collector area varying from 80-120 m2.The other parameters like hot storage tank, cold storage tank, pump, cooling tower etc are used. The simulation was carried out on TRANSOL Program for Bharatpur city situated in east of Rajasthan (INDIA. Sensitivity analysis shows that in coming future the as the total investment cost decreases and electricity prices increases, the payback period came down. If the total investment fall down to its 50% and electric prices are hike 50% than the payback period came down within the system life. Bestandsnummer des Verkäufers 9786202681193
Anzahl: 1 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Design and Performance Analysis of Solar Thermal Cooling System | Analysis of Solar Thermal Cooling System | Khagendra Kumar Upman (u. a.) | Taschenbuch | Englisch | 2020 | LAP LAMBERT Academic Publishing | EAN 9786202681193 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 120442788
Anzahl: 5 verfügbar