The present scenario of the modern power network has obligated protection system to perform better. Application of multi-functional measurement devices, inclusion of renewable sources and FACTS devices, and extreme utilization of transmission system are the major factors behind the undesired and unintentional operation of protection scheme. System stressed conditions like power swing, voltage instability and load encroachment are another concern for protection scheme. Protective relay operates beyond their setting guidelines and zones. This book investigates on distance and differential relaying for different power networks under different critical equipment and system operating conditions. Different innovative solutions based on local and remote end information are proposed for each critical condition.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Dr. Sandeep Biswal is received his Ph.D. degree in electrical engineering from NIT Raipur, India, in 2019 in the field of power system protection. His research interests include power system relaying and monitoring, microgrid protection etc. Dr. Biswal is a recipient of the POSOCO Power System Award, IIT Delhi, India in 2019.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The present scenario of the modern power network has obligated protection system to perform better. Application of multi-functional measurement devices, inclusion of renewable sources and FACTS devices, and extreme utilization of transmission system are the major factors behind the undesired and unintentional operation of protection scheme. System stressed conditions like power swing, voltage instability and load encroachment are another concern for protection scheme. Protective relay operates beyond their setting guidelines and zones. This book investigates on distance and differential relaying for different power networks under different critical equipment and system operating conditions. Different innovative solutions based on local and remote end information are proposed for each critical condition. 220 pp. Englisch. Bestandsnummer des Verkäufers 9786203857139
Anzahl: 2 verfügbar
Anbieter: Books Puddle, New York, NY, USA
Zustand: New. Bestandsnummer des Verkäufers 26401065599
Anzahl: 4 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. Print on Demand. Bestandsnummer des Verkäufers 395344288
Anzahl: 4 verfügbar
Anbieter: Biblios, Frankfurt am main, HESSE, Deutschland
Zustand: New. PRINT ON DEMAND. Bestandsnummer des Verkäufers 18401065589
Anzahl: 4 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Biswal SandeepDr. Sandeep Biswal is received his Ph.D. degree in electrical engineering from NIT Raipur, India, in 2019 in the field of power system protection. His research interests include power system relaying and monitoring, mic. Bestandsnummer des Verkäufers 478262435
Anzahl: Mehr als 20 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Innovative Power System Protection Algorithms | During Critical Equipment and Stress Conditions | Sandeep Biswal | Taschenbuch | Englisch | 2021 | LAP LAMBERT Academic Publishing | EAN 9786203857139 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 120201247
Anzahl: 5 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The present scenario of the modern power network has obligated protection system to perform better. Application of multi-functional measurement devices, inclusion of renewable sources and FACTS devices, and extreme utilization of transmission system are the major factors behind the undesired and unintentional operation of protection scheme. System stressed conditions like power swing, voltage instability and load encroachment are another concern for protection scheme. Protective relay operates beyond their setting guidelines and zones. This book investigates on distance and differential relaying for different power networks under different critical equipment and system operating conditions. Different innovative solutions based on local and remote end information are proposed for each critical condition.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 220 pp. Englisch. Bestandsnummer des Verkäufers 9786203857139
Anzahl: 1 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The present scenario of the modern power network has obligated protection system to perform better. Application of multi-functional measurement devices, inclusion of renewable sources and FACTS devices, and extreme utilization of transmission system are the major factors behind the undesired and unintentional operation of protection scheme. System stressed conditions like power swing, voltage instability and load encroachment are another concern for protection scheme. Protective relay operates beyond their setting guidelines and zones. This book investigates on distance and differential relaying for different power networks under different critical equipment and system operating conditions. Different innovative solutions based on local and remote end information are proposed for each critical condition. Bestandsnummer des Verkäufers 9786203857139
Anzahl: 1 verfügbar