In the recent past, India has seen mass destruction due to failure of structures hit earthquakes and consequently, lost a lot of lives. Hence, it is of utmost importance that attention be given to the evaluation of the adequacy of strength in RC framed structures to resist strong ground motions. In this project, a 15 year old four storey reinforced concrete structure has been considered, which lies in Seismic Zone III according to IS 1893:2002classification of seismic zones in India. For non-structural members masonry infill has been assumed. In the Equivalent Static Method of analysis, the seismic load acting on the structure is assumed to be an equivalent static horizontal force applied to individual frames. The total force applied shall be equal to the product of the acceleration response spectrum and the seismic weight. It is used only for low to high rise buildings without significant coupled lateral-torsional modes.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
Prof. Ganesh D. Lakade is Working as Asst. Prof. in Dept. of Civil Engineering at SKNSCOE, Maharashtra. He has expertise in Structural Design. He completed his BE degree in Civil Engineering from PVPIT, Sangli, Maharashtra (India), Completed his Masters in Civil Structural Engineering from SKN Sinhgad College of Engineering, Pandharpur. (India).
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: Books Puddle, Woodside, NY, USA
Zustand: New. Bestandsnummer des Verkäufers 26400903908
Anzahl: 4 verfügbar
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware 72 pp. Englisch. Bestandsnummer des Verkäufers 9786207455492
Anzahl: 2 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. Print on Demand. Bestandsnummer des Verkäufers 395505979
Anzahl: 4 verfügbar
Anbieter: Biblios, Frankfurt am main, HESSE, Deutschland
Zustand: New. PRINT ON DEMAND. Bestandsnummer des Verkäufers 18400903918
Anzahl: 4 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In the recent past, India has seen mass destruction due to failure of structures hit earthquakes and consequently, lost a lot of lives. Hence, it is of utmost importance that attention be given to the evaluation of the adequacy of strength in RC framed structures to resist strong ground motions. In this project, a 15 year old four storey reinforced concrete structure has been considered, which lies in Seismic Zone III according to IS 1893:2002classification of seismic zones in India. For non-structural members masonry infill has been assumed. In the Equivalent Static Method of analysis, the seismic load acting on the structure is assumed to be an equivalent static horizontal force applied to individual frames. The total force applied shall be equal to the product of the acceleration response spectrum and the seismic weight. It is used only for low to high rise buildings without significant coupled lateral-torsional modes. Bestandsnummer des Verkäufers 9786207455492
Anzahl: 1 verfügbar
Anbieter: moluna, Greven, Deutschland
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Ganesh LakadeProf. Ganesh D. Lakade is Working as Asst. Prof. in Dept. of Civil Engineering at SKNSCOE, Maharashtra. He has expertise in Structural Design. He completed his BE degree in Civil Engineering from PVPIT, Sangli, Maharasht. Bestandsnummer des Verkäufers 1361302056
Anzahl: Mehr als 20 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -In the recent past, India has seen mass destruction due to failure of structures hit earthquakes and consequently, lost a lot of lives. Hence, it is of utmost importance that attention be given to the evaluation of the adequacy of strength in RC framed structures to resist strong ground motions. In this project, a 15 year old four storey reinforced concrete structure has been considered, which lies in Seismic Zone III according to IS 1893:2002classification of seismic zones in India. For non-structural members masonry infill has been assumed. In the Equivalent Static Method of analysis, the seismic load acting on the structure is assumed to be an equivalent static horizontal force applied to individual frames. The total force applied shall be equal to the product of the acceleration response spectrum and the seismic weight. It is used only for low to high rise buildings without significant coupled lateral-torsional modes.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 72 pp. Englisch. Bestandsnummer des Verkäufers 9786207455492
Anzahl: 1 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. RC Building Under Dynamic Forces And Suitability Of FRP Strengthening | A Performance Evaluation | Ganesh Lakade | Taschenbuch | Englisch | 2023 | LAP LAMBERT Academic Publishing | EAN 9786207455492 | Verantwortliche Person für die EU: SIA OmniScriptum Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu. Bestandsnummer des Verkäufers 128336322
Anzahl: 5 verfügbar