Omnidirectional Inductive Powering for Biomedical Implants investigates the feasibility of inductive powering for capsule endoscopy and freely moving systems in general. The main challenge is the random position and orientation of the power receiving system with respect to the emitting magnetic field. Where classic inductive powering assumes a predictable or fixed alignment of the respective coils, the remote system is now free to adopt just any orientation while still maintaining full power capabilities. Before elaborating on different approaches towards omnidirectional powering, the design and optimisation of a general inductive power link is discussed in all its aspects. Special attention is paid to the interaction of the inductive power link with the patient’s body. Putting theory into practice, the implementation of an inductive power link for a capsule endoscope is included in a separate chapter.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
In the year 2000, a capsule endoscope was introduced on the market for diagnosis of small bowel diseases. This pill, about one centimeter in diameter, takes images of the gastric track and transmits them wirelessly to the outside world. Since the capsule is battery powered, the limited energy budget restricts both the amount and the quality of images that can be shot. To resolve this limitation, Omnidirectional Inductive Powering for Biomedical Implants investigates the feasibility of inductive powering for capsule endoscopy and freely moving systems in general. The main challenge is the random position and orientation of the power receiving system with respect to the emitting magnetic field. Where classic inductive powering assumes a predictable or fixed alignment of the respective coils, the remote system is now free to adopt just any orientation while still maintaining full power capabilities. Before elaborating on different approaches towards omnidirectional powering, the design and optimisation of a general inductive power link is discussed in all its aspects. Useful rectifier and inverter topologies are presented, including a class E driver that copes with coil deformations. Special attention is paid to the interaction of the inductive power link with the patient’s body. Putting theory into practice, the implementation of an inductive power link for a capsule endoscope is included in a separate chapter.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Anbieter: Brook Bookstore On Demand, Napoli, NA, Italien
Zustand: new. Questo è un articolo print on demand. Bestandsnummer des Verkäufers 3452bc9e370009680e36d5ada49eeffb
Anzahl: Mehr als 20 verfügbar
Anbieter: Ria Christie Collections, Uxbridge, Vereinigtes Königreich
Zustand: New. In. Bestandsnummer des Verkäufers ria9789048180622_new
Anzahl: Mehr als 20 verfügbar
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Omnidirectional Inductive Powering for Biomedical Implants investigates the feasibility of inductive powering for capsule endoscopy and freely moving systems in general. The main challenge is the random position and orientation of the power receiving system with respect to the emitting magnetic field. Where classic inductive powering assumes a predictable or fixed alignment of the respective coils, the remote system is now free to adopt just any orientation while still maintaining full power capabilities. Before elaborating on different approaches towards omnidirectional powering, the design and optimisation of a general inductive power link is discussed in all its aspects. Special attention is paid to the interaction of the inductive power link with the patient's body. Putting theory into practice, the implementation of an inductive power link for a capsule endoscope is included in a separate chapter. 240 pp. Englisch. Bestandsnummer des Verkäufers 9789048180622
Anzahl: 2 verfügbar
Anbieter: moluna, Greven, Deutschland
Kartoniert / Broschiert. Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Handbook on inductive link design, in-depth theoretical analysis plus implementationOnly existing analysis on 3D (omnidirectional) inductive powering systemsImplementation of an inductive link for a capsule endoscopeInterface study b. Bestandsnummer des Verkäufers 5821894
Anzahl: Mehr als 20 verfügbar
Anbieter: preigu, Osnabrück, Deutschland
Taschenbuch. Zustand: Neu. Omnidirectional Inductive Powering for Biomedical Implants | Bert Lenaerts (u. a.) | Taschenbuch | xvi | Englisch | 2010 | Springer | EAN 9789048180622 | Verantwortliche Person für die EU: Springer Verlag GmbH, Tiergartenstr. 17, 69121 Heidelberg, juergen[dot]hartmann[at]springer[dot]com | Anbieter: preigu. Bestandsnummer des Verkäufers 107142322
Anzahl: 5 verfügbar
Anbieter: Books Puddle, New York, NY, USA
Zustand: New. pp. 240. Bestandsnummer des Verkäufers 263076227
Anzahl: 4 verfügbar
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschland
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Magnetic Induction.- Inductive Link Design.- Power Converters and Voltage Regulators.- Omnidirectional Coupling.- Biological Tissue Interaction.- An Inductive Power Link for a Capsule Endoscope.- A Class E Driver for Deformable Coils.- Conclusions.Springer-Verlag KG, Sachsenplatz 4-6, 1201 Wien 240 pp. Englisch. Bestandsnummer des Verkäufers 9789048180622
Anzahl: 1 verfügbar
Anbieter: Majestic Books, Hounslow, Vereinigtes Königreich
Zustand: New. Print on Demand pp. 240 49:B&W 6.14 x 9.21 in or 234 x 156 mm (Royal 8vo) Perfect Bound on White w/Gloss Lam. Bestandsnummer des Verkäufers 5853020
Anzahl: 4 verfügbar
Anbieter: AHA-BUCH GmbH, Einbeck, Deutschland
Taschenbuch. Zustand: Neu. Druck auf Anfrage Neuware - Printed after ordering - Omnidirectional Inductive Powering for Biomedical Implants investigates the feasibility of inductive powering for capsule endoscopy and freely moving systems in general. The main challenge is the random position and orientation of the power receiving system with respect to the emitting magnetic field. Where classic inductive powering assumes a predictable or fixed alignment of the respective coils, the remote system is now free to adopt just any orientation while still maintaining full power capabilities. Before elaborating on different approaches towards omnidirectional powering, the design and optimisation of a general inductive power link is discussed in all its aspects. Special attention is paid to the interaction of the inductive power link with the patient's body. Putting theory into practice, the implementation of an inductive power link for a capsule endoscope is included in a separate chapter. Bestandsnummer des Verkäufers 9789048180622
Anzahl: 1 verfügbar
Anbieter: Biblios, Frankfurt am main, HESSE, Deutschland
Zustand: New. PRINT ON DEMAND pp. 240. Bestandsnummer des Verkäufers 183076233
Anzahl: 4 verfügbar