Abnormal Arteriovenous Communications : Great Variability of Effects with Particular Reference to Delayed Development of Cardiac Failure.

  • Softcover
  • Gebraucht
Alle Details anzeigen

Anbieter: Antiq. F.-D. Söhn - Medicusbooks.Com, Marburg, DeutschlandAntiq. F.-D. Söhn - Medicusbooks.Com

Verkäufer/-in mit 5 Sternen

Verkäufer:in bei AbeBooks seit 12. Januar 2006

Verbandsmitglied: VDAILAB

Softcover

Zustand: Gebraucht

EUR 33,00

EUR 36,45 Versand 
Versand von Deutschland nach USA

Anzahl: 1 verfügbar

In den Warenkorb
30 Tage kostenlose Rückgabe

Artikelbeschreibung des Verkäufers

Circulation, 32. - December 1965, 8°, pp.1001-1009, 7 Figs., orig. brochure. Rare Offprint! "From the Department of Surgery, standford University School of Medicine and Presbyterian Medical Center, San Francisco, California." "Clinical experiences and experimental studies provide evidence that an abnormal communication between the arterial and venous systems introduces into the circulation two circuits of flowing blood, one characterized by high arterial pressure and high peripheral resistance, and a second system bypassing part of the first, thus introducing a shorter circuit back to the heart, characterized by low pressure and low resistance, each supplied with flowing blood from the same central source, the heart. This shorter circuit acts solely as a parasitic circuit engrafted upon the normal circulation, serving no useful purpose, but capable of producing serious deleterious effects, depending upon the volume of blood diverted from the normal circulation into the shorter or parasitic circuit. Intimately dependent upon this diversion of differing volumes of blood into the shorter circuit is the great diversity in the effects of a peripheral fistula upon the heart: the complete absence of cardiac dilatation in some cases; the rapid development of cardiac dilatation and cardiac failure within 21/2 months as exemplified in Mason's case; and the long delay of 57 years in the development of cardiac failure as observed by Dorney. Due to the high pressure in the normal circuit and the low resistance in the fistula circuit, there is a constant tendency for blood to be diverted or sequestered, as it were, in the fistulous or parasitic circuit, the factors determining the volume of blood so diverted being the size of the fistula and the distensibility of its rim or border, this, in turn, being dependent upon the character of the fibrous tissue deposited around the fistula in the course of healing. Firm, rigid, and excessive scarring permits only a small volume of blood to be sequestered in the fistula circuit, dilating only mildly the components of the parasitic circuit, whereas an elastic and distensible fistulous border permits progressive expansion of the fistulous opening with a progressive increase in the volume of blood sequestered in the fistula circuit, causing progressive dilatation of all components of this circuit including the four chambers of the heart, the aorta and artery proximal to the fistula, the fistula itself, the proximal vein, the vena cava, and the pulmonary vascular bed. All gradations in distensibility of the fistula may occur, and hence all gradations in cardiac dilatation will occur. Also, all gradations in the rapidity of fistulous expansion may occur and, therefore, all gradations in rapidity of cardiac dilatation will occur. This concept of a progressive expansion of a fistula of slow or rapid development permitting more and more blood to be shunted or sequestered in a shorter parasitic circuit at very rapid or very slow rates of increase provides the long-sought explanation of the rapid or long-delayed development of cardiac dilatation and failure in the presence of a peripheral fistula. It is suggested that the same explanation is applicable to the effects of all abnormal arteriovenous communications, including intracardiac shunts and even some hemangiomata, since all are subject to the same hydrodynamic law that flowing blood like flowing water seeks the path of least resistance." Summary "Holman was the first to bring the Halstedian tradition to the West Coast. He established not only a surgical residency program but also the Halsted Laboratory of Surgical Research; in which he and a number of his faculty carried out important experiments. Holman is best known for his work on arteriovenous fistulas. His initial publication on this subject was in 1923; and his final one was in 1971. In between; he wrote more than 40 papers reflecting both laboratory and clinical .…

Bestandsnummer des Verkäufers 69250

Bibliografische Details

Titel
Abnormal Arteriovenous Communications : Great Variability of Effects with Particular Reference to Delayed Development of Cardiac Failure.
Autor
Holman, Emile
Erscheinungsjahr
1961
Einband
Softcover
Verkäuferkataloge
Chirurgie

Antiq. F.-D. Söhn - Medicusbooks.Com

Marburg, Deutschland

Verkäufer/-in mit 5 Sternen

Verkäufer:in bei AbeBooks seit 12. Januar 2006

Verbandsmitglied:

Versandkosten von Deutschland nach USA

Artikel8 bis 14 Werktage25 bis 45 Werktage
Erster ArtikelEUR 36,45EUR 36,45
Die Versandzeiten werden von den Verkäuferinnen und Verkäufern festgelegt. Sie variieren je nach Versanddienstleister und Standort. Sendungen, die den Zoll passieren, können Verzögerungen unterliegen. Eventuell anfallende Abgaben oder Gebühren sind von der Käuferin bzw. dem Käufer zu tragen. Die Verkäuferin bzw. der Verkäufer kann Sie bezüglich zusätzlicher Versandkosten kontaktieren, um einen möglichen Anstieg der Versandkosten für Ihre Artikel auszugleichen.

Zahlungsarten

  • Visa
  • Mastercard
  • American Express
  • Carte Bleue
  • Apple Pay
  • Google Pay
  • PayPal
  • Rechnung
  • Vorauskasse

Shopbeschreibung

Antiquariat für Medizin - Fritz-Dieter Söhn - MedicusBooks.Com, 35037 Marburg, Renthof 8, Deutschland, 0049-(0)6421-66002, office@medicusbooks.com - is a mail order firm founded in 1978 by Fritz-Dieter Söhn. It has one of the world's largest inventories of old, rare, and out-of-print books in medicine, surgery, and related fields -- more than 25,000 already registered titles and many more on stock. We have a comprehensive stock of secondary sources, books on medical history, medical biography, and medical bibliography. Our stock includes not only books but engraved prints to all medical subjects, as well portraits of physicians, surgeons, and medical scientists. We issue catalogues on all special fields of medicine on request so please order our catalogues. Please let us know what subjects and authors you search for, and be sure we respond to your want lists. …

Spezialisierung

Microscopy and Autographs, Medicine and allied sciences, Optics, Physics

Verbandsmitglied

  • Verband Deutscher Antiquare
  • International League of Antiquarian Booksellers
Die Mitglieder dieser Verbände haben sich verpflichtet, die höchsten Standards einzuhalten. Sie verbürgen sich für die Echtheit aller zum Verkauf angebotenen Artikel. Sie liefern fachkundige und detaillierte Beschreibungen, legen alle wesentlichen Mängel und/oder Restaurierungen offen, bieten klare und genaue Preisangaben und arbeiten während des Kaufprozesses fair und ehrlich.

Unternehmensdaten der Verkäuferin bzw. des Verkäufers

Antiq. F.-D. Söhn - Medicusbooks.Com

Deutschland