Industrial Electricity and Motor Controls Field Manual (Paperback)
Sprache: Englisch
Verlag: Independently Published, 2026
- Softcover
- Neu

Anbieter: CitiRetail, Stevenage, Vereinigtes KönigreichCitiRetail
Verkäufer:in bei AbeBooks seit 29. Juni 2022
Zustand: Neu
EUR 70,90
Anzahl: 1 verfügbar
In den WarenkorbArtikelbeschreibung des Verkäufers
Paperback. When a motor won't start and the fault in front of you doesn't match the diagram in the manual, what do you check first, and why?This field manual is written for industrial electricians, plant maintenance technicians, and advancing apprentices who need more than theory when they're standing at an open panel with a process down. It moves from the electrical fundamentals every industrial technician relies on daily, safety and lockout/tagout, circuit theory, three-phase power, conductor sizing, overcurrent protection and grounding, through motor theory, control circuits, starters, and reduced-voltage starting, into the systems that dominate modern plant floors: variable frequency drives and programmable logic controllers. Every chapter carries the book's Featuring The Fault-to-Fix Decision Path, a four-part reasoning block, Symptom, Likely Cause, Verification Test, Corrective Action, built around the exact judgment call an experienced technician makes when a fault doesn't match the textbook. The book closes with a full Master Index consolidating every Decision Path instance by symptom and by component, turning the manual into a quick-reference a technician can go back to on the job, not just read once and shelve.Inside, You Will FindTwenty chapters covering safety and lockout/tagout, circuit theory, three-phase power, conductors and NEC-based wiring, overcurrent protection and grounding, transformers, AC/DC motor theory, motor nameplate sizing, control circuits and ladder logic, starters and overload protection, reduced-voltage starting, VFD theory and fault diagnostics, PLC architecture and ladder logic programming, and systematic troubleshooting.The Fault-to-Fix Decision Path, a repeated four-part diagnostic reasoning block (Symptom, Likely Cause, Verification Test, Corrective Action) embedded throughout every chapter at the exact points a real fault is likely to occur.A closing Fault-to-Fix Master Index, indexing every Decision Path instance in the book by symptom and by component for fast field lookup.Mandatory Step-by-Step worked examples for every calculation, conductor sizing, overload trip class selection, VFD parameter commissioning, and more, with real inline and displayed mathematical notation, never spelled-out prose or raw formula text.Practical VFD fault code cross-reference guidance organized by underlying drive stage (rectifier, DC bus, inverter) so the reasoning transfers across manufacturers, not just one brand's fault code list.Ladder logic coverage spanning hardwired relay control through PLC-based motor control integration, including forcing, online editing, and safety practice.Full-color and line-art technical figures throughout: schematics, ladder diagrams, wiring diagrams, procedural sequences, and technical photography, drawn from a locked visual inventory matched to the sub-discipline.Currency-flagged code and safety guidance (NEC, OSHA, NFPA 70E) with a clear disclaimer that field values must always be verified against the current adopted code and the equipment nameplate.Keep it on the tool cart, not on a shelf. Whether you're commissioning a new VFD, chasing an intermittent control circuit fault, or mentoring an apprentice through their first lockout/tagout, this manual is built to be reopened on the job, not just read once. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability.…
Bestandsnummer des Verkäufers 9798160802435
- Titel
- Industrial Electricity and Motor Controls Field Manual (Paperback)
- Autor
- Roger T. Petrie
- Verlag
- Independently Published
- Erscheinungsjahr
- 2026
- Zustand
- new
- Einband
- Paperback
- Sprache
- Englisch
- ISBN-13
- 9798160802435
When a motor won't start and the fault in front of you doesn't match the diagram in the manual, what do you check first, and why?
This field manual is written for industrial electricians, plant maintenance technicians, and advancing apprentices who need more than theory when they're standing at an open panel with a process down. It moves from the electrical fundamentals every industrial technician relies on daily, safety and lockout/tagout, circuit theory, three-phase power, conductor sizing, overcurrent protection and grounding, through motor theory, control circuits, starters, and reduced-voltage starting, into the systems that dominate modern plant floors: variable frequency drives and programmable logic controllers. Every chapter carries the book's Featuring The Fault-to-Fix Decision Path, a four-part reasoning block, Symptom, Likely Cause, Verification Test, Corrective Action, built around the exact judgment call an experienced technician makes when a fault doesn't match the textbook. The book closes with a full Master Index consolidating every Decision Path instance by symptom and by component, turning the manual into a quick-reference a technician can go back to on the job, not just read once and shelve.
Inside, You Will Find
- Twenty chapters covering safety and lockout/tagout, circuit theory, three-phase power, conductors and NEC-based wiring, overcurrent protection and grounding, transformers, AC/DC motor theory, motor nameplate sizing, control circuits and ladder logic, starters and overload protection, reduced-voltage starting, VFD theory and fault diagnostics, PLC architecture and ladder logic programming, and systematic troubleshooting.
- The Fault-to-Fix Decision Path, a repeated four-part diagnostic reasoning block (Symptom, Likely Cause, Verification Test, Corrective Action) embedded throughout every chapter at the exact points a real fault is likely to occur.
- A closing Fault-to-Fix Master Index, indexing every Decision Path instance in the book by symptom and by component for fast field lookup.
- Mandatory Step-by-Step worked examples for every calculation, conductor sizing, overload trip class selection, VFD parameter commissioning, and more, with real inline and displayed mathematical notation, never spelled-out prose or raw formula text.
- Practical VFD fault code cross-reference guidance organized by underlying drive stage (rectifier, DC bus, inverter) so the reasoning transfers across manufacturers, not just one brand's fault code list.
- Ladder logic coverage spanning hardwired relay control through PLC-based motor control integration, including forcing, online editing, and safety practice.
- Full-color and line-art technical figures throughout: schematics, ladder diagrams, wiring diagrams, procedural sequences, and technical photography, drawn from a locked visual inventory matched to the sub-discipline.
- Currency-flagged code and safety guidance (NEC, OSHA, NFPA 70E) with a clear disclaimer that field values must always be verified against the current adopted code and the equipment nameplate.
Keep it on the tool cart, not on a shelf. Whether you're commissioning a new VFD, chasing an intermittent control circuit fault, or mentoring an apprentice through their first lockout/tagout, this manual is built to be reopened on the job, not just read once.
„Inhaltsangabe“ gehört möglicherweise zu einer anderen Auflage dieses Titels.
CitiRetail
Stevenage, Vereinigtes Königreich
Verkäufer:in bei AbeBooks seit 29. Juni 2022
Versandkosten von Vereinigtes Königreich nach USA
| Artikel | 7 bis 14 Werktage | 7 bis 60 Werktage |
|---|---|---|
| Erster Artikel | EUR 44,30 | EUR 44,30 |
Zahlungsarten
Shopbeschreibung
Online business
Unternehmensdaten der Verkäuferin bzw. des Verkäufers
ABC BOOKS LIMITED
10 John Street
London, Vereinigtes Königreich WC1N 2EB
Verkaufsbedingungen
Orders can be returned within 30 days of receipt.
Widerrufsrecht
Wenn Sie Verbraucher sind, können Sie gemäß den folgenden Bestimmungen vom Vertrag zurücktreten. Verbraucher ist jede natürliche Person, die zu Zwecken handelt, die nicht ihrer kaufmännischen, gewerblichen, künstlerischen oder beruflichen Tätigkeit zugerechnet werden können.
Informationen zum Widerrufsrecht
Gesetzliches Widerrufsrecht
Sie haben das Recht, den Vertrag innerhalb von 14 Tagen ohne Angabe von Gründen zu widerrufen.
Die Widerrufsfrist beträgt 14 Tage ab dem Tag, an dem Sie oder ein von Ihnen benannter Dritter, der nicht der Transporteur ist, die letzte Ware oder den letzten Posten oder das letzte Exemplar in Besitz genommen hat.
Um das Widerrufsrecht auszuüben, füllen Sie auf unserer Website unter „Meine Einkäufe" in „Mein Nutzerkonto" eine eindeutige Erklärung elektronisch aus und senden Sie sie ab. Wir werden Ihnen unverzüglich eine Bestätigung über den Eingang eines solchen Widerrufs auf einem dauerhaften Datenträger (z. B. per E-Mail) übermitteln.
Um die Widerrufsfrist einzuhalten, reicht es aus, dass Sie Ihre Mitteilung über die Ausübung des Widerrufsrechts vor Ablauf der Widerrufsfrist absenden.
Auswirkungen des Widerrufs
Wenn Sie diesen Vertrag widerrufen, erstatten wir Ihnen alle Zahlungen, die wir von Ihnen erhalten haben, einschließlich der Lieferkosten (mit Ausnahme der zusätzlichen Kosten, die entstehen, wenn Sie eine andere Art der Lieferung als die von uns angebotene günstigste Standardlieferung gewählt haben).
Wir können einen Abzug von der Rückerstattung für den Wertverlust der gelieferten Waren vornehmen, wenn der Verlust auf eine unnötige Behandlung durch Sie zurückzuführen ist.
Wir werden die Rückerstattung unverzüglich und nicht später als 14 Tage nach dem Tag vornehmen, an dem wir über Ihre Entscheidung, diesen Vertrag zu widerrufen, informiert wurden.
Für die Rückerstattung verwenden wir dasselbe Zahlungsmittel, das Sie für die ursprüngliche Transaktion verwendet haben, es sei denn, Sie haben ausdrücklich etwas anderes vereinbart; in keinem Fall werden Ihnen aufgrund einer solchen Rückerstattung Gebühren berechnet.
Wir können die Rückzahlung verweigern, bis wir die Waren wieder zurückerhalten haben oder Sie den Nachweis erbracht haben, dass Sie die Waren zurückgesandt haben, je nachdem, was eher eintritt.
Sie müssen die Waren unverzüglich und in jedem Fall spätestens 14 Tage ab dem Tag, an dem Sie uns über den Widerruf dieses Vertrags unterrichten, an CitiRetail, Stevenage, United Kingdom, zurücksenden oder übergeben. Die Frist ist eingehalten, wenn Sie die Ware vor Ablauf der Frist von 14 Tagen zurücksenden. Sie müssen die direkten Kosten der Rücksendung der Waren tragen. Sie haften nur für einen etwaigen Wertverlust der Waren, der auf eine Behandlung zurückzuführen ist, die nicht zur Prüfung der Art, Eigenschaften und Funktionsweise der Waren erforderlich ist.
Ausnahmen vom Widerrufsrecht
Das Widerrufsrecht gilt nicht für:
- Die Lieferung von Zeitungen, Zeitschriften oder Magazinen mit Ausnahme von Abonnementverträgen; und
- Die Lieferung digitaler Inhalte, die nicht auf einem physischen Medium (z. B. auf einer CD oder DVD) geliefert werden, wenn Sie bei Ihrer Bestellung akzeptiert haben, dass wir mit der Lieferung beginnen können und dass Sie nach Beginn der Lieferung den Vertrag nicht mehr widerrufen können.
Versandbedingungen
Please note that titles are dispatched from our US, Canadian or Australian warehouses. Delivery times specified in shipping terms. Orders ship within 2 business days. Delivery to your door then takes 7-14 days.