Introduction to Power System Protection (Paperback)

Sprache: Englisch

Verlag: Blurb, San Francisco, 2026

9798211894259

Anbieter: AussieBookSeller, Truganina, VIC, AustralienAussieBookSeller

Verkäufer/-in mit 5 Sternen

AbeBooks-Verkäufer/-in seit 22. Juni 2007

Artikel dieses Verkäufers ansehen
Softcover

Zustand: Neu

EUR 40,61

EUR 32,21 Versand 
Versand von Australien nach USA

Anzahl: 1 verfügbar

In den Warenkorb
Kostenlose Rückgaben innerhalb von 30 Tagen

Artikelbeschreibung vom Verkäufer

Paperback. Power system protection systems have three basic components: Instrument transformers, Relays, Circuit breakers The function of the CT is to reproduce in its secondary winding a current I' that is proportional to the primary current I. The CT converts primary currents in the kiloamp range to secondary currents in the 0-5 ampere range for convenience of measurement. The function of the relay is to discriminate between normal operation and fault conditions. The OC relay in Figure 2 has an operating coil, which is connected to the CT secondary winding, and a set of contacts. When I' exceeds a specified ''pickup'' value, the operating coil causes the normally open contacts to close. When the relay contacts close, the trip coil of the circuit breaker is energized, which then causes the circuit breaker to open. System-protection components have the following design criteria: - Reliability: Operate dependably when fault conditions occur, even after remaining idle for months or years. Failure to do so may result in costly damages. - Selectivity: Avoid unnecessary, false trips. - Speed: Operate rapidly to minimize fault duration and equipment damage. Any intentional time delays should be precise. - Economy: Provide maximum protection at minimum cost. - Simplicity: Minimize protection equipment and circuitry. Since it is impossible to satisfy all these criteria simultaneously, compromises must be made in system protection. The book consists from the following sections: 1. Chapter 1: Power System Faults: 2. Chapter 2: Instrument Transformers. 3. Chapter 3: Overcurrent and Earth Fault Protection Relays. 4. Chapter 4: Radial System Protection. 5. Chapter 5: Zones of Protection. 6. Chapter 6: Differential Relays. 7. Chapter 7: Distance Relays. 8. Chapter 8: Transformer Protection. 9. Chapter 9: Generator Protection. 10. Chapter 10: Busbar Protection. 11. Chapter 11: Circuit Breakers. 12. Chapter 12: Fuses. 13. Chapter 13: References. This item is printed on demand. Shipping may be from our Sydney, NSW warehouse or from our UK or US warehouse, depending on stock availability.

Bestandsnummer des Verkäufers 9798211894259

Titel
Introduction to Power System Protection (Paperback)
Autor
Dr Hidaia Mahmood Alassouli
Verlag
Blurb, San Francisco
Veröffentlichungsjahr
2026
Zustand
new
Einband
Paperback
Sprache
Englisch
ISBN-13
9798211894259

AussieBookSeller

Truganina, VIC, Australien

Verkäufer/-in mit 5 Sternen

AbeBooks-Verkäufer/-in seit 22. Juni 2007

Versandkosten von Australien nach USA

Artikel25 bis 45 Werktage8 bis 14 Werktage
Erster ArtikelEUR 32,21EUR 38,31
Die Versandzeiten werden von den Verkäuferinnen und Verkäufern festgelegt. Sie variieren je nach Versanddienstleister und Standort. Sendungen, die den Zoll passieren, können Verzögerungen unterliegen. Eventuell anfallende Abgaben oder Gebühren sind von der Käuferin bzw. dem Käufer zu tragen. Die Verkäuferin bzw. der Verkäufer kann Sie bezüglich zusätzlicher Versandkosten kontaktieren, um einen möglichen Anstieg der Versandkosten für Ihre Artikel auszugleichen.

Zahlungsarten

  • Visa
  • Mastercard
  • American Express
  • Carte Bleue
  • Apple Pay
  • Google Pay

Unternehmensdaten der Verkäuferin bzw. des Verkäufers

The Nile Group Pty Ltd

42 Apex Drive
Truganina, VIC Australien 3029