Micro Total Analysis Systems 2004 (Hb)
Verkauft von SMASS Sellers, IRVING, TX, USA
AbeBooks-Verkäufer seit 22. Februar 2022
Neu - Hardcover
Zustand: Neu
Versand innerhalb von USA
Anzahl: 1 verfügbar
In den Warenkorb legenVerkauft von SMASS Sellers, IRVING, TX, USA
AbeBooks-Verkäufer seit 22. Februar 2022
Zustand: Neu
Anzahl: 1 verfügbar
In den Warenkorb legenBrand New Original US Edition. Customer service! Satisfaction Guaranteed.
Bestandsnummer des Verkäufers ASNT3-249226
The Eighth International Conference on Miniaturized Systems in Chemistry and Life Science - µTas 2004 - is an annual meeting focusing on the research, development and application of miniaturized technologies and methodologies in chemistry and life science. The conference is celebrating its tenth anniversary after the first workshop at the University of Twente, The Netherlands in 1994. This research field is rapidly developing and changing towards a domain where core competence areas such as microfluidics, micro- and nanotechnology, materials science, chemistry, biology, and medicine are melting together to a truly interdisciplinary meeting place.
This volume is the first in a two volume set, a valuable reference collection to all working in this field.
Volume 1,
Day 1 - Monday, September 27, 2004,
Plenary I,
Monday Session A - Particle Sorting,
Monday Session B - Motormolecules,
Monday Session A - Cell Positioning,
Monday Session B - MEMS,
Monday Plenary II,
Monday Poster Sessions - Applications I,
Monday Poster Session - Microfluids I,
Monday Poster Session - Nanotechnology,
Monday Poster Session - Others,
Monday Session A - Fluid Pumping,
Monday Session B - Proteomics,
Day 1 - Tuesday, September 28, 2004,
Tuesday Session A-Cell Culture I,
Tuesday Session B - Nanochannels,
Tuesday Session A - Particles,
Tuesday Session B - Optical Detection,
Tuesday Plenary IV,
Tuesday Poster Session - Applications II,
Tuesday Poster Sessions - Microfluids II,
SINGLE MOLECULE NANO-BIOSCIENCE
Toshio Yanagida
Graduate School of Frontier Bioscience and Graduate School of Medicine, Osaka University, 1-3, Yamadaoka, Suita, Osaka, 565-0871, Japan
1. Introduction
Biomolecules assemble to form molecular machines such as molecular motors, cell signal processors, DNA transcription processors and protein synthesizers to fulfill their functions. Their collaboration allows the activity of biological systems. The reactions and behaviors of molecular machines vary flexibly while responding to their surroundings. This flexibility is essential for biological organisms. The underlying mechanism of molecular machines is not as simple as that expected from analogy with man-made machines. Since molecular machines are only nanometers in size and has a flexible structure, it is very prone to thermal agitation. Furthermore, the input energy level is not much difference from average thermal energy, kBT. Molecular machines can thus operate under the strong influence of this thermal noise, with a high efficiency of energy conversion. They would not overcome thermal noise but effectively use it for their functions. This is in sharp contrast to man-made machines that operate at energies much higher than the thermal noise. In recent years, the single molecule detection (SMD) and nano-technologies have rapidly been expanding to include a wide range of life science. The dynamic properties of biomolecules and the unique operations of molecular machines, which were previously hidden in averaged ensemble measurements, have now been unveiled. The aim of our research is to approach the engineering principle of adaptive biological system by uncovering the unique operation of biological molecular machines. I survey our SMD experiments designed to investigate molecular motors, enzyme reactions, protein dynamics and cell signaling, and discuss the mechanism of biological molecular machines.
2. Single-molecule detection (SMD) techniques
How advantageous is SMD for investigations? Observing and manipulating biomolecules allows their dynamic behaviors to be directly revealed, as has been demonstrated for motor proteins. Reactions of biological molecules are generally stochastic. Therefore, even if the reactions of molecules are initiated at the same time, they cannot be synchronized, so the dynamic behaviors of individual molecules are averaged and hidden in ensemble-averaged measurements. In vivo, biomolecules work in dynamic and complicated heterogeneous systems, involving different kinds of molecules such as cell-signaling proteins. It is difficult to quantitatively detect dynamic behaviors of target molecules in such systems by ensemble-averaged measurements. The SMD techniques are expected to overcome these difficulties and have already been successfully applied to study the dynamic properties of biological molecules such as motor proteins, enzymes, RNA polymerase and cell-signaling proteins.
The SMD techniques are based on two key technologies for single-molecule imaging and single-molecule nanomanipulation. First, the imaging technique will be explained. The size of biomolecules and even their assemblies are in the order of nanometers, so they are too small to observe by optical microscopy. To overcome this problem, biomolecules can be fluorescently labeled and visualized using fluorescence microscopy. Single fluorophores in aqueous solution were first observed in 1995 by using total internal reflection fluorescence microscopy (TIRFM) and conventional inverted fluorescence microscopy. The major problem to overcome when visualizing single fluorophores in aqueous solution is the huge background noise, which can be caused by Raman scattering from water molecules, incident light breaking through filters, luminescence arising from the objective lens, immersion oil and dust. In this system, the evanescent field was formed when the laser beam was totally reflected by the interface between the solution and the glass. The evanescent field was not restricted to the diffraction limit of light, thus it could be localized close to the glass surface, which resulted in the penetration depth (~150 nm) being several-fold shorter than the wavelength of light. Therefore, the illumination was restricted to fluorophores either bound to the glass surface or located close by, thereby reducing the background light. Furthermore, by careful selection of optical elements, the background noise could be reduced by 2000-fold compared with that of conventional fluorescence microscopy. This made it possible to clearly observe single fluorophores in aqueous solution. Fluorescence measurements from fluorophores attached to biomolecules and ligands allow the detection of, for example, the movements, conformational changes, enzymatic reactions and cell-signal processes of biomolecules at the single molecule level.
The second key technology is single-molecule nanomanipulation. Biomolecules and even single molecules can be captured by a glass needle or by beads trapped by optical tweezers. The optical tweezers are the tool to trap and manipulate particles of 25 nm to 25 µm in diameter by the force of laser radiation pressure. The particle is trapped near the focus of laser light when focused by a microscope objective with a high numerical aperture. The optical tweezers produce forces in the piconewton range on the particles. Biomolecules are too small to be directly trapped by the optical tweezers, so they are generally attached to an optically -trapped bead. Microneedles or a bead trapped by a laser act as a spring that expands in proportion to the applied force. Thus, the force and the displacement caused by the biomolecules can be measured. The displacement of a microneedle and a bead has been determined with a subnanometer accuracy, much less than the diffraction limit of an optical measurement. This accuracy of displacement corresponds to the sub-piconewton accuracy in the force measurements. Thus, the mechanical property of biomolecules can be determined directly at the single-molecule level. Furthermore, combined with the single-molecule imaging technique, simultaneous measurements of mechanical and chemical reactions of single biomolecules are possible.
3. Movement and ATPase turnovers of biological molecular motors
The SDM techniques were first used to...
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
We sell Brand New Textbooks requied for studies in the Univesity. We have been in this business for the past 14 years and we know how to keep our customers happy and satisfies by providing them the required course material and the most affordable prices.
Wenn Sie Verbraucher sind, steht Ihnen ein Widerrufsrecht nach folgender Maßgabe zu. Verbraucher ist jede natürliche Person, die ein Rechtsgeschäft zu Zwecken abschließt, die überwiegend weder ihrer gewerblichen noch ihrer selbständigen beruflichen Tätigkeit zugerechnet werden können.
WIDERRUFSBELEHRUNG
Widerrufsrecht
Sie haben das Recht, binnen vierzehn Tagen ohne Angabe von Gründen diesen Vertrag zu widerrufen.
Die Widerrufsfrist beträgt vierzehn Tage ab dem Tag, an dem Sie oder ein von Ihnen benannter Dritter, der nicht der Beförderer ist, die letzte Ware oder die letzte Teilsendung bzw. das letzte Stück in Besitz genommen haben bzw. hat.
Um Ihr Widerrufsrecht auszuüben, müssen Sie uns, SMASS Sellers, 1944 LOMA LINDA DR., 75063-3924, IRVING, Texas, U.S.A., +1 4699865502, mittels einer eindeutigen Erklärung (z.B. ein mit der Post versandter Brief, Telefax oder E-Mail) über Ihren Entschluss, diesen Vertrag zu widerrufen, informieren. Sie können dafür das beigefügte Muster-Widerrufsformular verwenden, das jedoch nicht vorgeschrieben ist. Sie können auch eine andere eindeutige Erklärung auf der Webseite "Meine Bestellungen" in Ihrem "Nutzerkonto" elektronisch ausfüllen und übermitteln. Machen Sie von dieser Möglichkeit Gebrauch, so werden wir Ihnen unverzüglich (z. B. per E-Mail) eine Bestätigung über den Eingang eines solchen Widerrufs übermitteln. Zur Wahrung der Widerrufsfrist reicht es aus, dass Sie die Mitteilung über die Ausübung des Widerrufsrechts vor Ablauf der Widerrufsfrist absenden.
Folgen des Widerrufs
Wenn Sie diesen Vertrag widerrufen, haben wir Ihnen alle Zahlungen, die wir von Ihnen erhalten haben, einschließlich der Lieferkosten (mit Ausnahme der zusätzlichen Kosten, die sich daraus ergeben, dass Sie eine andere Art der Lieferung als die von uns angebotene, günstigste Standardlieferung gewählt haben), unverzüglich und spätestens binnen vierzehn Tagen ab dem Tag zurückzuzahlen, an dem die Mitteilung über Ihren Widerruf dieses Vertrags bei uns eingegangen ist. Für diese Rückzahlung verwenden wir dasselbe Zahlungsmittel, das Sie bei der ursprünglichen Transaktion eingesetzt haben, es sei denn, mit Ihnen wurde ausdrücklich etwas anderes vereinbart; in keinem Fall werden Ihnen wegen dieser Rückzahlung Entgelte berechnet. Wir können die Rückzahlung verweigern, bis wir die Waren wieder zurückerhalten haben oder bis Sie den Nachweis erbracht haben, dass Sie die Waren zurückgesandt haben, je nachdem, welches der frühere Zeitpunkt ist. Sie haben die Waren unverzüglich und in jedem Fall spätestens binnen vierzehn Tagen ab dem Tag, an dem Sie uns über den Widerruf dieses Vertrags unterrichten, an SMASS Sellers, 1944 LOMA LINDA DR., 75063-3924, IRVING, Texas, U.S.A., +1 4699865502, zurückzusenden oder zu übergeben. Die Frist ist gewahrt, wenn Sie die Waren vor Ablauf der Frist von vierzehn Tagen absenden.
Sie tragen die unmittelbaren Kosten der Rücksendung der Waren. Sie müssen für einen etwaigen Wertverlust der Waren nur aufkommen, wenn dieser Wertverlust auf einen zur Prüfung der Beschaffenheit, Eigenschaften und Funktionsweise der Waren nicht notwendigen Umgang mit ihnen zurückzuführen ist.
Ausnahmen vom Widerrufsrecht
Das Widerrufsrecht besteht nicht bzw. erlischt bei folgenden Verträgen:
ENDE DER WIDERRUFSBELEHRUNG
Muster-Widerrufsformular
(Wenn Sie den Vertrag widerrufen wollen, dann füllen Sie bitte dieses Formular aus und senden Sie es zurück)
An: (SMASS Sellers, 1944 LOMA LINDA DR., 75063-3924, IRVING, Texas, U.S.A., +1 4699865502)
Hiermit widerrufe(n) ich/wir* den von mir/uns* abgeschlossenen Vertrag über den Kauf der folgenden Waren*/ die Erbringung der folgenden Dienstleistung*
Bestellt am*/erhalten am*:
Name des/der Verbraucher(s):
Anschrift des/der Verbraucher(s):
Unterschrift des/der Verbraucher(s) (nur bei Mitteilung auf Papier):
Datum:
* Unzutreffendes streichen.
We ship all orders from our Multiple warehouses by Tracakble method only. We have tie up with Fedex, DHL, UPS and USPS for our logistics requirements. All tracking numbers are available within 48 hours of processing the order.
| Bestellmenge | 5 bis 10 Werktage | 3 bis 6 Werktage |
|---|---|---|
| Erster Artikel | EUR 0.00 | EUR 0.00 |
Die Versandzeiten werden von den Verkäuferinnen und Verkäufern festgelegt. Sie variieren je nach Versanddienstleister und Standort. Sendungen, die den Zoll passieren, können Verzögerungen unterliegen. Eventuell anfallende Abgaben oder Gebühren sind von der Käuferin bzw. dem Käufer zu tragen. Die Verkäuferin bzw. der Verkäufer kann Sie bezüglich zusätzlicher Versandkosten kontaktieren, um einen möglichen Anstieg der Versandkosten für Ihre Artikel auszugleichen.