Principles and Practices of Method Validation
Sprache: Englisch
Verlag: RSC Publishing Okt 2000, 2000
- Hardcover
- Neu

Anbieter: AHA-BUCH GmbH, Einbeck, DeutschlandAHA-BUCH GmbH
Verkäufer:in bei AbeBooks seit 14. August 2006
Zustand: Neu
EUR 163,94
Anzahl: 2 verfügbar
In den WarenkorbArtikelbeschreibung des Verkäufers
Neuware - Principles and Practices of Method Validation is an overview of the most recent approaches used for method validation in cases when a large number of analytes are determined from a single aliquot and where a large number of samples are to be analysed. Much of the content relates to the validation of new methods for pesticide residue analysis in foodstuffs and water but the principles can be applied to other similar fields of analysis. Different chromatographic methods are discussed, including estimation of various effects, eg. matrix-induced effects and the influence of the equipment set-up. The methods used for routine purposes and the validation of analytical data in the research and development environment are documented. The legislation covering the EU-Guidance on residue analytical methods, an extensive review of the existing in-house method validation documentation and guidelines for single-laboratory validation of analytical methods for trace-level concentrations of organic chemicals are also included. With contributions from experts in the field, any practising analyst dealing with method validation will find the examples presented in this book a useful source of technical information.…
Bestandsnummer des Verkäufers 9780854047833
- Titel
- Principles and Practices of Method Validation
- Autor
- A. Ambrus
- Verlag
- RSC Publishing Okt 2000
- Erscheinungsjahr
- 2000
- Zustand
- Neu
- Einband
- Buch
- Sprache
- Englisch
- ISBN-10
- 0854047832
- ISBN-13
- 9780854047833
- Artikelgewicht
- 590 Gramm
- Abmessungen
- 239x162x24 mm
Principles and Practices of Method Validation is an overview of the most recent approaches used for method validation in cases when a large number of analytes are determined from a single aliquot and where a large number of samples are to be analysed. Much of the content relates to the validation of new methods for pesticide residue analysis in foodstuffs and water but the principles can be applied to other similar fields of analysis. Different chromatographic methods are discussed, including estimation of various effects, eg. matrix-induced effects and the influence of the equipment set-up. The methods used for routine purposes and the validation of analytical data in the research and development environment are documented. The legislation covering the EU-Guidance on residue analytical methods, an extensive review of the existing in-house method validation documentation and guidelines for single-laboratory validation of analytical methods for trace-level concentrations of organic chemicals are also included. With contributions from experts in the field, any practising analyst dealing with method validation will find the examples presented in this book a useful source of technical information.
„Inhaltsangabe“ gehört möglicherweise zu einer anderen Auflage dieses Titels.
Auszug. © Genehmigter Nachdruck. Alle Rechte vorbehalten.
Principles and Practices of Method Validation
By A. Fajgelj, Á. AmbrusThe Royal Society of Chemistry
All rights reserved.
Contents
The Potential Use of Quality Control Data to Validate Pesticide Residue Method Performance W. Horwitz, 1,
Optimization and Evaluation of Multi-residue Methods for Priority Pesticides in Drinking and Related Waters P. Van Wiele, F. Van Hoof, A. Bruchet, I. Schmitz, J.L. Guinumant, F. Acobas, A. Ventura, F. Sacher, I. Bobeldijk and M.H. Marecos do Monte, 9,
Validation of Analytical Data in a Research and Development Environment R. Hoogerbugge and P. van Zoonen, 19,
Performance Validation of a Multi-residue Method for 170 Pesticides in Kiwifruit P.T. Holland, A.J. Boyd and C.P. Malcolm, 29,
Testing the Efficiency and Uncertainty of Sample Processing Using 14C-Labelled Chlorpyrifos: Part I. Description of the Methodology B. Maestroni, A. Ghods, M. El-Bidaoui, N. Rathor, O. P. Jarju, T. Ton and Á. Ambrus, 79,
Testing the Efficiency and Uncertainty of Sample Processing Using 14-Labelled Chlorpyrifos: Part II B. Maestroni, A. Ghods, M. El-Bidaoui, N. Rathor, O.P. Jarju, T. Ton and Á. Ambrus, 59,
Testing the Effect of Sample Processing and Storage on the Stability of Residues M. El-Bidaoui, O.P. Jarju, B. Maestroni, Y. Phakaeiw and Á. Ambrus, 75,
AOAC International Collaborative Study on the Determination of Pesticide Residues in Nonfatty Foods by Supercritical Fluid Extraction and Gas Chromatography/Mass Spectrometry S.J. Lehotay, 89,
Validation of Analytical Methods – Proving Your Method is 'Fit for Purpose' J.D. MacNeil, J. Patterson and V. Martz, 100,
Validation of a Multi-residue Method for Analysis of Pesticides in Fruit, Vegetables and Cereals by a GC/MS Iontrap System M.E. Poulsen and K, Granby, 108,
Development and Validation of a Generic Gas Chromatographic Method for the Determination of Organophosphorus Pesticide Residues in Various Sample Extracts H. Botitsi, P. Kormali, S. Kontou, A. Mourkojanni and D. Tsipi, 120,
Validation of Gas Chromatographic Databases for Qualitative Identification of Active Ingredients of Pesticide Residues J. Lantos, L Kadencki, F. Zakar and Á. Ambrus, 128,
Estimation of Significance of 'Matrix-induced' Chromatographic Effects E. Soboleva, N. Rathor, A. Mageto and Á. Ambrus, 138,
Worked Example for Validation of a Multi-residue Method Á. Ambrus, 157,
EU Guidance Documents on Residue Analytical Methods R. Hänel, J. Siebers and K. Howard, 176,
Guidelines for Single-Laboratory Validation of Analytical Methods for Trace-level Concentrations of Organic Chemicals, 179,
A Critique on Available In-House Method Validation Documentation P. Willets and R. Wood, 253,
Subject Index, 297,
CHAPTER 1
The Potential Use of Quality Control Data to Validate Pesticide Residue Method Performance
William Honvitz
CENTER FOR FOOD SAFETY AND APPLIED NUTRITION HFS-500, US FOOD AND DRUG ADMINISTRATION, WASHINGTON DC 20204, USA
Full scale interlaboratory (collaborative) studies are becoming too expensive and time-consuming to support their use as the only way to validate methods of analysis. Furthermore, reliable estimates of method performance parameters, such as accuracy, precision, and limits of applicability, cannot be achieved by individual collaborative studies at the concentration levels of 0.01-1 mg. kg-1 the region of interest for residue analysis, when the expected random error among laboratories is of the order of 20-30% of the mean. Performance data from proficiency studies of tens of thousands of control determinations accumulated over the past decade from individual and multiple laboratories are being examined to determine their potential as a substitute for interlaboratory performance data. An analysis of variance indicates that as much as 80% of the total variability of pesticide residue analysis is "random error." If this is the case, proficiency data may be substituted for method-performance data, when recovery is acceptable, because the individual factors of analyte, method, matrix, laboratory, and time contribute little to overall variability.
1 INTRODUCTION
A full-scale method performance study, utilizing the IUPAC-AOAC harmonized protocol,' requires a minimum of 8 laboratories to analyze at least 5 materials related to the analyte-matrix-concentration combinations of interest by the proposed method. Although such a study is probably the most pertinent and reliable way of demonstrating the performance of a method with a specific test sample, several alternatives are also available. The Youden pair technique (split level design) conducted at several relevant concentration levels is the model favored by the extensive water analysis program of the U.S. Environmental Protection Agency (EPA). In Europe, the "uncertainty" budget approach has been advocated, particularly in conjunction with laboratory accreditation, although this design has been modified during the past few years to become more similar to the method-performance model.
All of these models are expensive and time-consuming. What few calculations that have been conducted independently suggest that they do not provide the same performance parameters with the same method from the same data and information. Proficiency testing, also advocated by the FAO/WHO Codex Alimentarius Program as a way of demonstrating equivalency in laboratory results, has been suggested as still another potential substitute for the method-performance trials. The purpose of this paper is to explore this possibility.
2 AVAILABLE PROFICIENCY STUDIES
Data from several large scale proficiency programs have been made available to us in order to examine their potential use as a substitute for method performance in the determination of pesticide residues in food. As of late 1999, data from three programs have been examined. These include the following:
2.1 Total Diet Program (FDA-TD)
The Total Diet Program of the U.S. Food and Drug Administration (FDA), Kansas City Laboratory, has been in continuous operation for almost 40 years. The recoveries of approximately 7000 control determinations of analytes added to individual foods in the pesticide residue portion of the 4 annual market baskets analyzed during 1991-1997 were available as databases in EXCEL4. This is a within-laboratory program.
2.2 Food Analysis Performance Assessment Schemes (FAPAS)
This is an international fee-based program conducted by the Ministry of Agriculture, Fisheries, and Food of the United Kingdom. Each test material is thoroughly homogenized to a smooth paste and aliquots of stock standard solutions of pesticides of known purity are added with additional mixing. The fortified test material is measured into screw top glass jars, tested for homogeneity, and stored at -20° until shipped. More than 100 laboratories participated in many of the tests. Participants were required to submit their results within 8 weeks for their values to be included in a report that was distributed. The pesticide residue reports (Nos. 1901-1905), uncorrected for recovery, and percent recovery of about 1100 concurrent controls that were submitted, were the data used in the present examination.
2.3 State of California Quality Assurance Program (CA)
The State of California has been monitoring the quality of their Residue Enforcement Program since 1988, utilizing their headquarters and field...
„Über diesen Titel“ gehört möglicherweise zu einer anderen Auflage dieses Titels.
AHA-BUCH GmbH
Einbeck, Deutschland
Verkäufer:in bei AbeBooks seit 14. August 2006
Versandkosten von Deutschland nach USA
| Artikel | 7 bis 10 Werktage | 5 bis 7 Werktage |
|---|---|---|
| Erster Artikel | EUR 35,00 | EUR 45,00 |
Zahlungsarten
- Banküberweisung
- PayPal
- Vorauskasse
Shopbeschreibung
Das Unternehmen AHA-BUCH GmbH: Seit der Gründung von AHA-BUCH im Juli 2005 ist unser Hauptziel, zufriedenen Kunden so schnell und so preisgünstig wie möglich ihren Bücherwunsch zu erfüllen. Unsere Firma beschäftigt 16 Mitarbeiter, die nur ein Ziel kennen: den Kunden und seine Wünsche! Auf über 3700 m2 Fläche haben wir über 100.000 Bücher, Modernes Antiquariat und Spiele auf Lager.
Spezialisierung
Kinderbücher & Kinderhör Casetten, German Books, Software, Natur & Tiere, Ratgeber, Sachbücher, Englische Bücher, Medizin & Gesundheit, Universität & StudiumUnternehmensdaten der Verkäuferin bzw. des Verkäufers
AHA-BUCH GmbH
Garlebsen 48
Einbeck, Deutschland 37574
Verkaufsbedingungen
Impressum
Gesetzliche Anbieterkennung:
AHA-BUCH GmbH
diese vertreten durch den Geschäftsführer Christel Glass
Garlebsen 48
37574 Einbeck
Deutschland
Telefon: 055639996039
Telefax: 055639995974
E-Mail: abebooks@aha-buch.de
USt-IdNr.: DE261904229
eingetragen im Handelsregister des Amtsgerichtes Göttingen
Handelsregisternummer HRB 200691
Alternative Streitbeilegung:
Die Europäische Kommission stellt eine Plattform für die außergerichtliche Online-Streitbeilegung (OS-Plattform) bereit, aufrufbar unter https://ec.europa.eu/odr.
Wir sind seit 25.05.2018 Mitglied der Initiative "FairCommerce".
Nähere Informationen hierzu finden Sie unter www.fair-commerce.de.
Widerrufsrecht
Wenn Sie Verbraucher sind, können Sie gemäß den folgenden Bestimmungen vom Vertrag zurücktreten. Verbraucher ist jede natürliche Person, die zu Zwecken handelt, die nicht ihrer kaufmännischen, gewerblichen, künstlerischen oder beruflichen Tätigkeit zugerechnet werden können.
Informationen zum Widerrufsrecht
Gesetzliches Widerrufsrecht
Sie haben das Recht, den Vertrag innerhalb von 14 Tagen ohne Angabe von Gründen zu widerrufen.
Die Widerrufsfrist beträgt 14 Tage ab dem Tag, an dem Sie oder ein von Ihnen benannter Dritter, der nicht der Transporteur ist, die letzte Ware oder den letzten Posten oder das letzte Exemplar in Besitz genommen hat.
Um das Widerrufsrecht auszuüben, füllen Sie auf unserer Website unter „Meine Einkäufe" in „Mein Nutzerkonto" eine eindeutige Erklärung elektronisch aus und senden Sie sie ab. Wir werden Ihnen unverzüglich eine Bestätigung über den Eingang eines solchen Widerrufs auf einem dauerhaften Datenträger (z. B. per E-Mail) übermitteln.
Um die Widerrufsfrist einzuhalten, reicht es aus, dass Sie Ihre Mitteilung über die Ausübung des Widerrufsrechts vor Ablauf der Widerrufsfrist absenden.
Auswirkungen des Widerrufs
Wenn Sie diesen Vertrag widerrufen, erstatten wir Ihnen alle Zahlungen, die wir von Ihnen erhalten haben, einschließlich der Lieferkosten (mit Ausnahme der zusätzlichen Kosten, die entstehen, wenn Sie eine andere Art der Lieferung als die von uns angebotene günstigste Standardlieferung gewählt haben).
Wir können einen Abzug von der Rückerstattung für den Wertverlust der gelieferten Waren vornehmen, wenn der Verlust auf eine unnötige Behandlung durch Sie zurückzuführen ist.
Wir werden die Rückerstattung unverzüglich und nicht später als 14 Tage nach dem Tag vornehmen, an dem wir über Ihre Entscheidung, diesen Vertrag zu widerrufen, informiert wurden.
Für die Rückerstattung verwenden wir dasselbe Zahlungsmittel, das Sie für die ursprüngliche Transaktion verwendet haben, es sei denn, Sie haben ausdrücklich etwas anderes vereinbart; in keinem Fall werden Ihnen aufgrund einer solchen Rückerstattung Gebühren berechnet.
Wir können die Rückzahlung verweigern, bis wir die Waren wieder zurückerhalten haben oder Sie den Nachweis erbracht haben, dass Sie die Waren zurückgesandt haben, je nachdem, was eher eintritt.
Sie müssen die Waren unverzüglich und in jedem Fall spätestens 14 Tage ab dem Tag, an dem Sie uns über den Widerruf dieses Vertrags unterrichten, an AHA-BUCH GmbH, Einbeck, Germany, zurücksenden oder übergeben. Die Frist ist eingehalten, wenn Sie die Ware vor Ablauf der Frist von 14 Tagen zurücksenden. Sie müssen die direkten Kosten der Rücksendung der Waren tragen. Sie haften nur für einen etwaigen Wertverlust der Waren, der auf eine Behandlung zurückzuführen ist, die nicht zur Prüfung der Art, Eigenschaften und Funktionsweise der Waren erforderlich ist.
Ausnahmen vom Widerrufsrecht
Das Widerrufsrecht gilt nicht für:
- Die Lieferung von Zeitungen, Zeitschriften oder Magazinen mit Ausnahme von Abonnementverträgen; und
- Die Lieferung digitaler Inhalte, die nicht auf einem physischen Medium (z. B. auf einer CD oder DVD) geliefert werden, wenn Sie bei Ihrer Bestellung akzeptiert haben, dass wir mit der Lieferung beginnen können und dass Sie nach Beginn der Lieferung den Vertrag nicht mehr widerrufen können.
Versandbedingungen
Wir liefern Lagerartikel innerhalb von 24 Stunden nach Erhalt der Bestellung aus.
Barsortimentsartikel, die wir über Nacht geliefert bekommen, am darauffolgenden Werktag.
Unser Ziel ist es Ihnen die Artikel in der ökonomischten und effizientesten Weise zu senden.