Principles and Practices of Method Validation
Verkauft von PBShop.store US, Wood Dale, IL, USA
AbeBooks-Verkäufer seit 7. April 2005
Neu - Hardcover
Zustand: Neu
Versand innerhalb von USA
Anzahl: 15 verfügbar
In den Warenkorb legenVerkauft von PBShop.store US, Wood Dale, IL, USA
AbeBooks-Verkäufer seit 7. April 2005
Zustand: Neu
Anzahl: 15 verfügbar
In den Warenkorb legenNew Book. Shipped from UK. Established seller since 2000.
Bestandsnummer des Verkäufers CX-9780854047833
Principles and Practices of Method Validation is an overview of the most recent approaches used for method validation in cases when a large number of analytes are determined from a single aliquot and where a large number of samples are to be analysed. Much of the content relates to the validation of new methods for pesticide residue analysis in foodstuffs and water but the principles can be applied to other similar fields of analysis. Different chromatographic methods are discussed, including estimation of various effects, eg. matrix-induced effects and the influence of the equipment set-up. The methods used for routine purposes and the validation of analytical data in the research and development environment are documented. The legislation covering the EU-Guidance on residue analytical methods, an extensive review of the existing in-house method validation documentation and guidelines for single-laboratory validation of analytical methods for trace-level concentrations of organic chemicals are also included. With contributions from experts in the field, any practising analyst dealing with method validation will find the examples presented in this book a useful source of technical information.
The Potential Use of Quality Control Data to Validate Pesticide Residue Method Performance W. Horwitz, 1,
Optimization and Evaluation of Multi-residue Methods for Priority Pesticides in Drinking and Related Waters P. Van Wiele, F. Van Hoof, A. Bruchet, I. Schmitz, J.L. Guinumant, F. Acobas, A. Ventura, F. Sacher, I. Bobeldijk and M.H. Marecos do Monte, 9,
Validation of Analytical Data in a Research and Development Environment R. Hoogerbugge and P. van Zoonen, 19,
Performance Validation of a Multi-residue Method for 170 Pesticides in Kiwifruit P.T. Holland, A.J. Boyd and C.P. Malcolm, 29,
Testing the Efficiency and Uncertainty of Sample Processing Using 14C-Labelled Chlorpyrifos: Part I. Description of the Methodology B. Maestroni, A. Ghods, M. El-Bidaoui, N. Rathor, O. P. Jarju, T. Ton and Á. Ambrus, 79,
Testing the Efficiency and Uncertainty of Sample Processing Using 14-Labelled Chlorpyrifos: Part II B. Maestroni, A. Ghods, M. El-Bidaoui, N. Rathor, O.P. Jarju, T. Ton and Á. Ambrus, 59,
Testing the Effect of Sample Processing and Storage on the Stability of Residues M. El-Bidaoui, O.P. Jarju, B. Maestroni, Y. Phakaeiw and Á. Ambrus, 75,
AOAC International Collaborative Study on the Determination of Pesticide Residues in Nonfatty Foods by Supercritical Fluid Extraction and Gas Chromatography/Mass Spectrometry S.J. Lehotay, 89,
Validation of Analytical Methods – Proving Your Method is 'Fit for Purpose' J.D. MacNeil, J. Patterson and V. Martz, 100,
Validation of a Multi-residue Method for Analysis of Pesticides in Fruit, Vegetables and Cereals by a GC/MS Iontrap System M.E. Poulsen and K, Granby, 108,
Development and Validation of a Generic Gas Chromatographic Method for the Determination of Organophosphorus Pesticide Residues in Various Sample Extracts H. Botitsi, P. Kormali, S. Kontou, A. Mourkojanni and D. Tsipi, 120,
Validation of Gas Chromatographic Databases for Qualitative Identification of Active Ingredients of Pesticide Residues J. Lantos, L Kadencki, F. Zakar and Á. Ambrus, 128,
Estimation of Significance of 'Matrix-induced' Chromatographic Effects E. Soboleva, N. Rathor, A. Mageto and Á. Ambrus, 138,
Worked Example for Validation of a Multi-residue Method Á. Ambrus, 157,
EU Guidance Documents on Residue Analytical Methods R. Hänel, J. Siebers and K. Howard, 176,
Guidelines for Single-Laboratory Validation of Analytical Methods for Trace-level Concentrations of Organic Chemicals, 179,
A Critique on Available In-House Method Validation Documentation P. Willets and R. Wood, 253,
Subject Index, 297,
The Potential Use of Quality Control Data to Validate Pesticide Residue Method Performance
William Honvitz
CENTER FOR FOOD SAFETY AND APPLIED NUTRITION HFS-500, US FOOD AND DRUG ADMINISTRATION, WASHINGTON DC 20204, USA
Full scale interlaboratory (collaborative) studies are becoming too expensive and time-consuming to support their use as the only way to validate methods of analysis. Furthermore, reliable estimates of method performance parameters, such as accuracy, precision, and limits of applicability, cannot be achieved by individual collaborative studies at the concentration levels of 0.01-1 mg. kg-1 the region of interest for residue analysis, when the expected random error among laboratories is of the order of 20-30% of the mean. Performance data from proficiency studies of tens of thousands of control determinations accumulated over the past decade from individual and multiple laboratories are being examined to determine their potential as a substitute for interlaboratory performance data. An analysis of variance indicates that as much as 80% of the total variability of pesticide residue analysis is "random error." If this is the case, proficiency data may be substituted for method-performance data, when recovery is acceptable, because the individual factors of analyte, method, matrix, laboratory, and time contribute little to overall variability.
1 INTRODUCTION
A full-scale method performance study, utilizing the IUPAC-AOAC harmonized protocol,' requires a minimum of 8 laboratories to analyze at least 5 materials related to the analyte-matrix-concentration combinations of interest by the proposed method. Although such a study is probably the most pertinent and reliable way of demonstrating the performance of a method with a specific test sample, several alternatives are also available. The Youden pair technique (split level design) conducted at several relevant concentration levels is the model favored by the extensive water analysis program of the U.S. Environmental Protection Agency (EPA). In Europe, the "uncertainty" budget approach has been advocated, particularly in conjunction with laboratory accreditation, although this design has been modified during the past few years to become more similar to the method-performance model.
All of these models are expensive and time-consuming. What few calculations that have been conducted independently suggest that they do not provide the same performance parameters with the same method from the same data and information. Proficiency testing, also advocated by the FAO/WHO Codex Alimentarius Program as a way of demonstrating equivalency in laboratory results, has been suggested as still another potential substitute for the method-performance trials. The purpose of this paper is to explore this possibility.
2 AVAILABLE PROFICIENCY STUDIES
Data from several large scale proficiency programs have been made available to us in order to examine their potential use as a substitute for method performance in the determination of pesticide residues in food. As of late 1999, data from three programs have been examined. These include the following:
2.1 Total Diet Program (FDA-TD)
The Total Diet Program of the U.S. Food and Drug Administration (FDA), Kansas City Laboratory, has been in continuous operation for almost 40 years. The recoveries of approximately 7000 control determinations of analytes added to individual foods in the pesticide residue portion of the 4 annual market baskets analyzed during 1991-1997 were available as databases in EXCEL4. This is a within-laboratory program.
2.2 Food Analysis Performance Assessment Schemes (FAPAS)
This is an international fee-based program conducted by the Ministry of Agriculture, Fisheries, and Food of the United Kingdom. Each test material is thoroughly homogenized to a smooth paste and aliquots of stock standard solutions of pesticides of known purity are added with additional mixing. The fortified test material is measured into screw top glass jars, tested for homogeneity, and stored at -20° until shipped. More than 100 laboratories participated in many of the tests. Participants were required to submit their results within 8 weeks for their values to be included in a report that was distributed. The pesticide residue reports (Nos. 1901-1905), uncorrected for recovery, and percent recovery of about 1100 concurrent controls that were submitted, were the data used in the present examination.
2.3 State of California Quality Assurance Program (CA)
The State of California has been monitoring the quality of their Residue Enforcement Program since 1988, utilizing their headquarters and field...
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Returns Policy
We ask all customers to contact us for authorisation should they wish to return their order. Orders returned without authorisation may not be credited.
If you wish to return, please contact us within 14 days of receiving your order to obtain authorisation.
Returns requested beyond this time will not be authorised.
Our team will provide full instructions on how to return your order and once received our returns department will process your refund.
Please note the cost to return any...
Wenn Sie Verbraucher sind, steht Ihnen ein Widerrufsrecht nach folgender Maßgabe zu. Verbraucher ist jede natürliche Person, die ein Rechtsgeschäft zu Zwecken abschließt, die überwiegend weder ihrer gewerblichen noch ihrer selbständigen beruflichen Tätigkeit zugerechnet werden können.
WIDERRUFSBELEHRUNG
Widerrufsrecht
Sie haben das Recht, binnen vierzehn Tagen ohne Angabe von Gründen diesen Vertrag zu widerrufen.
Die Widerrufsfrist beträgt vierzehn Tage ab dem Tag, an dem Sie oder ein von Ihnen benannter Dritter, der nicht der Beförderer ist, die letzte Ware oder die letzte Teilsendung bzw. das letzte Stück in Besitz genommen haben bzw. hat.
Um Ihr Widerrufsrecht auszuüben, müssen Sie uns, Paperbackshop-US, 901 Penhorn Avenue, Unit 6, 07094, Secaucus, New Jersey, U.S.A., 44 1285 712917, mittels einer eindeutigen Erklärung (z.B. ein mit der Post versandter Brief, Telefax oder E-Mail) über Ihren Entschluss, diesen Vertrag zu widerrufen, informieren. Sie können dafür das beigefügte Muster-Widerrufsformular verwenden, das jedoch nicht vorgeschrieben ist. Sie können auch eine andere eindeutige Erklärung auf der Webseite "Meine Bestellungen" in Ihrem "Nutzerkonto" elektronisch ausfüllen und übermitteln. Machen Sie von dieser Möglichkeit Gebrauch, so werden wir Ihnen unverzüglich (z. B. per E-Mail) eine Bestätigung über den Eingang eines solchen Widerrufs übermitteln. Zur Wahrung der Widerrufsfrist reicht es aus, dass Sie die Mitteilung über die Ausübung des Widerrufsrechts vor Ablauf der Widerrufsfrist absenden.
Folgen des Widerrufs
Wenn Sie diesen Vertrag widerrufen, haben wir Ihnen alle Zahlungen, die wir von Ihnen erhalten haben, einschließlich der Lieferkosten (mit Ausnahme der zusätzlichen Kosten, die sich daraus ergeben, dass Sie eine andere Art der Lieferung als die von uns angebotene, günstigste Standardlieferung gewählt haben), unverzüglich und spätestens binnen vierzehn Tagen ab dem Tag zurückzuzahlen, an dem die Mitteilung über Ihren Widerruf dieses Vertrags bei uns eingegangen ist. Für diese Rückzahlung verwenden wir dasselbe Zahlungsmittel, das Sie bei der ursprünglichen Transaktion eingesetzt haben, es sei denn, mit Ihnen wurde ausdrücklich etwas anderes vereinbart; in keinem Fall werden Ihnen wegen dieser Rückzahlung Entgelte berechnet. Wir können die Rückzahlung verweigern, bis wir die Waren wieder zurückerhalten haben oder bis Sie den Nachweis erbracht haben, dass Sie die Waren zurückgesandt haben, je nachdem, welches der frühere Zeitpunkt ist. Sie haben die Waren unverzüglich und in jedem Fall spätestens binnen vierzehn Tagen ab dem Tag, an dem Sie uns über den Widerruf dieses Vertrags unterrichten, an Paperbackshop-US, PaperbackShopUS, 801 Penhorn Avenue Unit 5, 07094, Secaucus, New Jersey, U.S.A., 44 1285 712917, zurückzusenden oder zu übergeben. Die Frist ist gewahrt, wenn Sie die Waren vor Ablauf der Frist von vierzehn Tagen absenden.
Sie tragen die unmittelbaren Kosten der Rücksendung der Waren. Sie müssen für einen etwaigen Wertverlust der Waren nur aufkommen, wenn dieser Wertverlust auf einen zur Prüfung der Beschaffenheit, Eigenschaften und Funktionsweise der Waren nicht notwendigen Umgang mit ihnen zurückzuführen ist.
Ausnahmen vom Widerrufsrecht
Das Widerrufsrecht besteht nicht bzw. erlischt bei folgenden Verträgen:
ENDE DER WIDERRUFSBELEHRUNG
Muster-Widerrufsformular
(Wenn Sie den Vertrag widerrufen wollen, dann füllen Sie bitte dieses Formular aus und senden Sie es zurück)
An: (Paperbackshop-US, 901 Penhorn Avenue, Unit 6, 07094, Secaucus, New Jersey, U.S.A., 44 1285 712917)
Hiermit widerrufe(n) ich/wir* den von mir/uns* abgeschlossenen Vertrag über den Kauf der folgenden Waren*/ die Erbringung der folgenden Dienstleistung*
Bestellt am*/erhalten am*:
Name des/der Verbraucher(s):
Anschrift des/der Verbraucher(s):
Unterschrift des/der Verbraucher(s) (nur bei Mitteilung auf Papier):
Datum:
* Unzutreffendes streichen.
Books are shipped from our US or UK warehouses. Delivery estimates allow for delivery from either location.
| Bestellmenge | 7 bis 14 Werktage | 7 bis 14 Werktage |
|---|---|---|
| Erster Artikel | EUR 0.00 | EUR 0.00 |
Die Versandzeiten werden von den Verkäuferinnen und Verkäufern festgelegt. Sie variieren je nach Versanddienstleister und Standort. Sendungen, die den Zoll passieren, können Verzögerungen unterliegen. Eventuell anfallende Abgaben oder Gebühren sind von der Käuferin bzw. dem Käufer zu tragen. Die Verkäuferin bzw. der Verkäufer kann Sie bezüglich zusätzlicher Versandkosten kontaktieren, um einen möglichen Anstieg der Versandkosten für Ihre Artikel auszugleichen.