Isbn: 9783845429595 - transient stability analysis: a novel method for transient stability analysis of a multimachine power system (6 Ergebnisse)

ISBN: 
Mit der Detailsuche verfeinern

Optimieren Sie Ihre Suche

  • Bücher (6)

bis

Benutzerdefinierte Preisspanne (EUR)

bis

  • Sprache: Englisch

    Verlag: LAP LAMBERT Academic Publishing, 2011

    3845429593 / 9783845429595

    • Softcover

    Anbieter: preigu, Osnabrück, Deutschlandpreigu

    Verkäufer/-in mit 5 Sternen
    Verkäufer/-in kontaktieren

    Zustand: Neu

    EUR 43,40

    EUR 70,00 Versand 
    Versand von Deutschland nach USA

    Anzahl: 5 verfügbar

    Taschenbuch. Zustand: Neu. Transient Stability Analysis | A Novel Method for Transient Stability Analysis of a Multimachine Power System | Md. Abdus Salam | Taschenbuch | 80 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783845429595 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. …

  • Sprache: Englisch

    Verlag: LAP LAMBERT Academic Publishing, 2011

    3845429593 / 9783845429595

    • Softcover

    Anbieter: Mispah books, Redhill, SURRE, Vereinigtes KönigreichMispah books

    Verkäufer/-in mit 4 Sternen
    Verkäufer/-in kontaktieren

    Zustand: Gebraucht - Wie neu

    EUR 122,92

    EUR 29,54 Versand 
    Versand von Vereinigtes Königreich nach USA

    Anzahl: 1 verfügbar

    Paperback. Zustand: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

  • Sprache: Englisch

    Verlag: LAP LAMBERT Academic Publishing Sep 2011, 2011

    3845429593 / 9783845429595

    • Softcover
    • Print-on-Demand

    Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, DeutschlandBuchWeltWeit Ludwig Meier e.K.

    Verkäufer/-in mit 5 Sternen
    Verkäufer/-in kontaktieren

    Zustand: Neu

    EUR 49,00

    EUR 23,00 Versand 
    Versand von Deutschland nach USA

    Anzahl: 2 verfügbar

    Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book is written based on my M. Sc. Engineering thesis. The method uses a set of closed loop transfer functions, one for each synchronous machine and derived by taking Laplace transformation of the machine s nonlinear swing equation in a tricky way. The transfer function directly takes into account the time of fault clearing and the changes in the maximum electrical power output of the machine due to changes in the prefault network topology during and after clearing the fault. The earliest possible location of the root of the characteristic equation (the denominator of the transfer function equated to zero) is searched in the s-plane for each machine starting from a real value of s which is the same for all the machines. The narrowest possible range i. e the lower and upper limits of the location is found by observing sign changes of the transfer function expression evaluated at several step values of s obtained by increasing starting value by a suitable chosen increment. 80 pp. Englisch.…

  • Sprache: Englisch

    Verlag: LAP LAMBERT Academic Publishing, 2011

    3845429593 / 9783845429595

    • Softcover
    • Print-on-Demand

    Anbieter: AHA-BUCH GmbH, Einbeck, DeutschlandAHA-BUCH GmbH

    Verkäufer/-in mit 5 Sternen
    Verkäufer/-in kontaktieren

    Zustand: Neu

    EUR 54,71

    EUR 35,00 Versand 
    Versand von Deutschland nach USA

    Anzahl: 1 verfügbar

    Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book is written based on my M. Sc. Engineering thesis. The method uses a set of closed loop transfer functions, one for each synchronous machine and derived by taking Laplace transformation of the machine s nonlinear swing equation in a tricky way. The transfer function directly takes into account the time of fault clearing and the changes in the maximum electrical power output of the machine due to changes in the prefault network topology during and after clearing the fault. The earliest possible location of the root of the characteristic equation (the denominator of the transfer function equated to zero) is searched in the s-plane for each machine starting from a real value of s which is the same for all the machines. The narrowest possible range i. e the lower and upper limits of the location is found by observing sign changes of the transfer function expression evaluated at several step values of s obtained by increasing starting value by a suitable chosen increment.…

  • Sprache: Englisch

    Verlag: LAP LAMBERT Academic Publishing, 2011

    3845429593 / 9783845429595

    • Softcover
    • Print-on-Demand

    Anbieter: moluna, Greven, Deutschlandmoluna

    Verkäufer/-in mit 5 Sternen
    Verkäufer/-in kontaktieren

    Zustand: Neu

    EUR 41,05

    EUR 48,99 Versand 
    Versand von Deutschland nach USA

    Anzahl: Mehr als 20 verfügbar

    Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Salam Md. AbdusHe obtained his B. Sc., M. Sc. and PhD all in Electrical Engineering from CUET,Chittagong, BUET, Dhaka and UTM, Malaysia respectively. He was a faculty member at CUET from 1994 to 2001. He worked as an Assistant Profes.…

  • Sprache: Englisch

    Verlag: LAP LAMBERT Academic Publishing Sep 2011, 2011

    3845429593 / 9783845429595

    • Softcover
    • Print-on-Demand

    Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschlandbuchversandmimpf2000

    Verkäufer/-in mit 5 Sternen
    Verkäufer/-in kontaktieren

    Zustand: Neu

    EUR 49,00

    EUR 60,00 Versand 
    Versand von Deutschland nach USA

    Anzahl: 1 verfügbar

    Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book is written based on my M. Sc. Engineering thesis. The method uses a set of closed loop transfer functions, one for each synchronous machine and derived by taking Laplace transformation of the machine¿s nonlinear swing equation in a tricky way. The transfer function directly takes into account the time of fault clearing and the changes in the maximum electrical power output of the machine due to changes in the prefault network topology during and after clearing the fault. The earliest possible location of the root of the characteristic equation (the denominator of the transfer function equated to zero) is searched in the s-plane for each machine starting from a real value of s which is the same for all the machines. The narrowest possible range i. e the lower and upper limits of the location is found by observing sign changes of the transfer function expression evaluated at several step values of s obtained by increasing starting value by a suitable chosen increment.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 80 pp. Englisch.…