ISBN: 9786207494101 - determination of the ct scan parameters: for the customisation of 3d-printed implants using an animal specimen (4 Ergebnisse)

Optimieren Sie Ihre Suche

  • Bücher (4)

  • Neu (4)

bis

Benutzerdefinierte Preisspanne (EUR)

bis

  • Weitere Bilder

    Sprache: Englisch

    Verlag: Our Knowledge Publishing, 2024

    6207494105 / 9786207494101

    • Softcover

    Anbieter: preigu, Osnabrück, Deutschlandpreigu

    Verkäufer/-in mit 5 Sternen
    Verkäufer/-in kontaktieren

    Zustand: Neu

    EUR 27,15

    EUR 70,00 Versand 
    Versand von Deutschland nach USA

    Anzahl: 5 verfügbar

    Taschenbuch. Zustand: Neu. Determination of the CT scan parameters | for the customisation of 3D-printed implants using an animal specimen | Yasmin Soleyman | Taschenbuch | Englisch | 2024 | Our Knowledge Publishing | EAN 9786207494101 | Verantwortliche Person für die EU: SIA OmniScriptum Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu.…

  • Sprache: Englisch

    Verlag: Our Knowledge Publishing Apr 2024, 2024

    6207494105 / 9786207494101

    • Softcover
    • Print-on-Demand

    Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, DeutschlandBuchWeltWeit Ludwig Meier e.K.

    Verkäufer/-in mit 5 Sternen
    Verkäufer/-in kontaktieren

    Zustand: Neu

    EUR 29,90

    EUR 23,00 Versand 
    Versand von Deutschland nach USA

    Anzahl: 2 verfügbar

    Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware 52 pp. Englisch.

  • Sprache: Englisch

    Verlag: Our Knowledge Publishing, 2024

    6207494105 / 9786207494101

    • Softcover
    • Print-on-Demand

    Anbieter: AHA-BUCH GmbH, Einbeck, DeutschlandAHA-BUCH GmbH

    Verkäufer/-in mit 5 Sternen
    Verkäufer/-in kontaktieren

    Zustand: Neu

    EUR 35,74

    EUR 35,00 Versand 
    Versand von Deutschland nach USA

    Anzahl: 1 verfügbar

    Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The work focuses on determining suitable CT scan parameters for fitting 3D-printed implants using an animal specimen, specifically for the scapula. By investigating different CT scan protocols with different reconstruction parameters, the aim is to find settings that provide sufficient resolution and dose for implant planning. In this regard, the practical part involves performing CT scans of the animal specimen with different parameters, which are then used to create 3D models and finally to produce 3D-printed implants. It is also pointed out that this approach takes into account in vitro factors but does not fully incorporate potential in vivo factors. The results emphasize the importance of reconstructions with the thinnest slice thickness from all scans for effective implant planning.…

  • Sprache: Englisch

    Verlag: Our Knowledge Publishing Apr 2024, 2024

    6207494105 / 9786207494101

    • Softcover
    • Print-on-Demand

    Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschlandbuchversandmimpf2000

    Verkäufer/-in mit 5 Sternen
    Verkäufer/-in kontaktieren

    Zustand: Neu

    EUR 29,90

    EUR 60,00 Versand 
    Versand von Deutschland nach USA

    Anzahl: 1 verfügbar

    Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The work focuses on determining suitable CT scan parameters for fitting 3D-printed implants using an animal specimen, specifically for the scapula. By investigating different CT scan protocols with different reconstruction parameters, the aim is to find settings that provide sufficient resolution and dose for implant planning. In this regard, the practical part involves performing CT scans of the animal specimen with different parameters, which are then used to create 3D models and finally to produce 3D-printed implants. It is also pointed out that this approach takes into account in vitro factors but does not fully incorporate potential in vivo factors. The results emphasize the importance of reconstructions with the thinnest slice thickness from all scans for effective implant planning.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 52 pp. Englisch.…