THE MODERN MICROPROCESSOR BASED ELECTRONIC EQUIPMENT MOST VULNERABLE TO INTENTIONAL DESTRUCTIVE ELECTROMAGNETIC INTERFERENCES (IDEI) INCLUDES HIGH–ALTITUDE ELECTROMAGNETIC PULSE (HEMP) IN ALL SUBSTATION EQUIPMENT. HOWEVER, POWER EQUIPMENT AND ESPECIALLY TRANSFORMERS ARE ALSO SUBJECT TO THE INFLUENCE OF HEMP. THE BOOK DISCUSSES PROBLEMS AND SOLUTIONS FOR BOTH KINDS OF SUBSTATION EQUIPMENT. SEPARATED INTO EIGHT CHAPTERS, THE BOOK COVERS: TECHNOLOGICAL PROGRESS AND ITS CONSEQUENCES; INTENTIONAL DESTRUCTIVE ELECTROMAGNETIC INTERFERENCES (IDEI); METHODS AND MEANS OF DIGITAL PROTECTIVE RELAY (DPR) PROTECTION FROM ELECTROMAGNETIC PULSE; PASSIVE METHODS AND MEANS OF DPR PROTECTION FROM ELECTROMAGNETIC PULSE; ACTIVE METHODS AND MEANS OF DPR PROTECTION FROM ELECTROMAGNETIC PULSE; TESTS OF DPR RESISTANCE TO IDEI IMPACTS; ORGANIZATIONAL AND TECHNICAL MEASURES TO PROTECT DPR FROM HEMP; AND PROTECTION OF POWER EQUIPMENT AND TRANSFORMERS FROM HEMP. KEY FEATURES: PRACTICAL APPROACH FOCUSING ON TECHNICAL SOLUTIONS FOR DIFFICULT PROBLEMS. FULL DATA ON ELECTROMAGNETIC THREATS AND METHODS OF THEIR PREVENTION ARE CONCENTRATED. ADDRESSES A GAP IN KNOWLEDGE IN THE POWER SYSTEM INDUSTRY. THIS BOOK EMPHASIZES PRACTICAL RECOMMENDATIONS ON PROTECTION OF POWER SUBSTATIONS' ELECTRIC EQUIPMENT FROM IDEI THAT INTENDED FOR NOT ONLY STAFF OPERATING ELECTRIC EQUIPMENT, BUT ALSO FOR MANUFACTURERS OF THIS EQUIPMENT, SPECIALISTS OF DESIGNING COMPANIES, MANAGERS OF ELECTRIC ENERGY INDUSTRY AS WELL AS FOR TEACHERS AND POSTGRADUATE STUDENTS.
Die Inhaltsangabe kann sich auf eine andere Ausgabe dieses Titels beziehen.
'This book provides background information on EMP and practical solutions for protecting power networks ... There are a variety of interesting protection circuits discussed and many interesting photos of unusual power distribution equipment and test equipment' IEEE, October 2017
The modern microprocessor based electronic equipment most vulnerable to Intentional Destructive Electromagnetic Interferences (IDEI) includes High-Altitude Electromagnetic Pulse (HEMP) in all substation equipment. However, power equipment and especially transformers are also subject to the influence of HEMP. The book discusses problems and solutions for both kinds of substation equipment. Separated into eight chapters, the book covers: Technological progress and its consequences; Intentional Destructive Electromagnetic Interferences (IDEI); Methods and means of Digital Protective Relay (DPR) protection from electromagnetic pulse; Passive methods and means of DPR protection from electromagnetic pulse; Active methods and means of DPR protection from electromagnetic pulse; Tests of DPR resistance to IDEI impacts; Organizational and technical measures to protect DPR from HEMP; and Protection of power equipment and transformers from HEMP. Key features: * Practical approach focusing on technical solutions for difficult problems. * Full data on electromagnetic threats and methods of their prevention are concentrated. * Addresses a gap in knowledge in the power system industry. This book emphasizes practical recommendations on protection of power substations' electric equipment from IDEI that intended for not only staff operating electric equipment, but also for manufacturers of this equipment, specialists of designing companies, managers of electric energy industry as well as for teachers and postgraduate students.
„Über diesen Titel“ kann sich auf eine andere Ausgabe dieses Titels beziehen.
Versand:
Gratis
Innerhalb der USA
Versand:
EUR 2,42
Innerhalb der USA
Anbieter: ThriftBooks-Atlanta, AUSTELL, GA, USA
Hardcover. Zustand: Very Good. No Jacket. May have limited writing in cover pages. Pages are unmarked. ~ ThriftBooks: Read More, Spend Less 1.15. Bestandsnummer des Verkäufers G1119271436I4N00
Anzahl: 1 verfügbar
Anbieter: SecondSale, Montgomery, IL, USA
Zustand: Good. Item in good condition. Textbooks may not include supplemental items i.e. CDs, access codes etc. Bestandsnummer des Verkäufers 00017721104
Anzahl: 1 verfügbar
Anbieter: The Happy Book Stack, Murfreesboro, TN, USA
Zustand: Good. Book may have little to no writing and/or underlining inside, and is in overall good condition. Cover may have some cosmetic wear. Fast shipping! Bestandsnummer des Verkäufers 5ALSUN0001PP_ns
Anzahl: 1 verfügbar
Anbieter: Turgid Tomes, Nashville, TN, USA
hardcover. Zustand: As New. First Edition. Wiley, 2017. Hard cover, first American edition. Fine condition with no dust jacket, as issued. Bestandsnummer des Verkäufers SKU1082414
Anzahl: 1 verfügbar
Anbieter: GreatBookPrices, Columbia, MD, USA
Zustand: As New. Unread book in perfect condition. Bestandsnummer des Verkäufers 25227291
Anzahl: 19 verfügbar
Anbieter: GreatBookPrices, Columbia, MD, USA
Zustand: New. Bestandsnummer des Verkäufers 25227291-n
Anzahl: 2 verfügbar
Anbieter: INDOO, Avenel, NJ, USA
Zustand: New. Bestandsnummer des Verkäufers 9781119271437
Anzahl: Mehr als 20 verfügbar
Anbieter: Grand Eagle Retail, Fairfield, OH, USA
Hardcover. Zustand: new. Hardcover. The modern microprocessor based electronic equipment most vulnerable to Intentional Destructive Electromagnetic Interferences (IDEI) includes High-Altitude Electromagnetic Pulse (HEMP) in all substation equipment. However, power equipment and especially transformers are also subject to the influence of HEMP. The book discusses problems and solutions for both kinds of substation equipment. Separated into eight chapters, the book covers: Technological progress and its consequences; Intentional Destructive Electromagnetic Interferences (IDEI); Methods and means of Digital Protective Relay (DPR) protection from electromagnetic pulse; Passive methods and means of DPR protection from electromagnetic pulse; Active methods and means of DPR protection from electromagnetic pulse; Tests of DPR resistance to IDEI impacts; Organizational and technical measures to protect DPR from HEMP; and Protection of power equipment and transformers from HEMP. Key features: Practical approach focusing on technical solutions for difficult problems.Full data on electromagnetic threats and methods of their prevention are concentrated.Addresses a gap in knowledge in the power system industry. This book emphasizes practical recommendations on protection of power substations' electric equipment from IDEI that intended for not only staff operating electric equipment, but also for manufacturers of this equipment, specialists of designing companies, managers of electric energy industry as well as for teachers and postgraduate students. The modern microprocessor based electronic equipment most vulnerable to Intentional Destructive Electromagnetic Interferences (IDEI) includes High-Altitude Electromagnetic Pulse (HEMP) in all substation equipment. However, power equipment and especially transformers are also subject to the influence of HEMP. Shipping may be from multiple locations in the US or from the UK, depending on stock availability. Bestandsnummer des Verkäufers 9781119271437
Anzahl: 1 verfügbar
Anbieter: GreatBookPricesUK, Woodford Green, Vereinigtes Königreich
Zustand: As New. Unread book in perfect condition. Bestandsnummer des Verkäufers 25227291
Anzahl: 19 verfügbar
Anbieter: Ubiquity Trade, Miami, FL, USA
Zustand: New. Brand new! Please provide a physical shipping address. Bestandsnummer des Verkäufers 9781119271437
Anzahl: Mehr als 20 verfügbar