Oltion korini (6 Ergebnisse)

- Softcover
Anbieter: Revaluation Books, Exeter, Vereinigtes KönigreichRevaluation Books
Verkäufer/-in kontaktierenVerkäufer/-in mit 5 SternenZustand: Neu
EUR 100,84
EUR 12,01 VersandVersand von Vereinigtes Königreich nach USAAnzahl: 1 verfügbar
Paperback. Zustand: Brand New. 140 pages. 8.66x5.91x0.32 inches. In Stock.

- Softcover
Anbieter: preigu, Osnabrück, Deutschlandpreigu
Verkäufer/-in kontaktierenVerkäufer/-in mit 5 SternenZustand: Neu
EUR 48,95
EUR 70,00 VersandVersand von Deutschland nach USAAnzahl: 5 verfügbar
Taschenbuch. Zustand: Neu. Seismic Assessment of Masonry Buildings Using Nonlinear Analysis | Nonlinear 3D pushover analysis of unreinforced masonry buildings using SAP2000 software and FEMA440 | Oltion Korini | Taschenbuch | 140 S. | Englisch | 2016 | LAP LAMBERT Academic Publishing | EAN 9783659915024 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.…

- Softcover
- Print-on-Demand
Anbieter: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, DeutschlandBuchWeltWeit Ludwig Meier e.K.
Verkäufer/-in kontaktierenVerkäufer/-in mit 5 SternenZustand: Neu
EUR 55,90
EUR 23,00 VersandVersand von Deutschland nach USAAnzahl: 2 verfügbar
Taschenbuch. Zustand: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Masonry is one of the most commonly used materials not only in Albania but also worldwide for the construction of low to mid rise buildings. Recent strong earthquakes in different countries have shown that masonry buildings suffered severe damage and caused loss of lives. Therefore it is important to assess the seismic performance of these buildings and based upon this evaluation, techniques should be developed for the strengthening of building stock against future earthquake damages. The purpose of this study is to evaluate the seismic performance of three residential buildings with selected template designs in Albania considering the nonlinear behavior of masonry. A nonlinear modeling method is developed in SAP2000 software and calibrated by 3Muri software. The capacity curves of the investigated buildings were determined by pushover analyses conducted in two principal directions. Seismic performance evaluation was carried out in accordance with the FEMA440 guidelines. The graphical-analytical procedure described there is used for performance evaluation. The analysis shows that two out of three selected buildings do not satisfy the required performance levels. 140 pp. Englisch.…

- Softcover
- Print-on-Demand
Anbieter: AHA-BUCH GmbH, Einbeck, DeutschlandAHA-BUCH GmbH
Verkäufer/-in kontaktierenVerkäufer/-in mit 5 SternenZustand: Neu
EUR 55,90
EUR 35,00 VersandVersand von Deutschland nach USAAnzahl: 1 verfügbar
Taschenbuch. Zustand: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Masonry is one of the most commonly used materials not only in Albania but also worldwide for the construction of low to mid rise buildings. Recent strong earthquakes in different countries have shown that masonry buildings suffered severe damage and caused loss of lives. Therefore it is important to assess the seismic performance of these buildings and based upon this evaluation, techniques should be developed for the strengthening of building stock against future earthquake damages. The purpose of this study is to evaluate the seismic performance of three residential buildings with selected template designs in Albania considering the nonlinear behavior of masonry. A nonlinear modeling method is developed in SAP2000 software and calibrated by 3Muri software. The capacity curves of the investigated buildings were determined by pushover analyses conducted in two principal directions. Seismic performance evaluation was carried out in accordance with the FEMA440 guidelines. The graphical-analytical procedure described there is used for performance evaluation. The analysis shows that two out of three selected buildings do not satisfy the required performance levels.…

- Softcover
- Print-on-Demand
Anbieter: moluna, Greven, Deutschlandmoluna
Verkäufer/-in kontaktierenVerkäufer/-in mit 5 SternenZustand: Neu
EUR 46,18
EUR 48,99 VersandVersand von Deutschland nach USAAnzahl: Mehr als 20 verfügbar
Zustand: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Korini OltionOltion Korini was born in Albania in 1984. He has pursued his Bachelor and Master of Science in Civil Engineering in Polytechnic University of Tirana in 2002-2007. He also holds a Master at Epoka University. He continues.…

- Softcover
- Print-on-Demand
Anbieter: buchversandmimpf2000, Emtmannsberg, BAYE, Deutschlandbuchversandmimpf2000
Verkäufer/-in kontaktierenVerkäufer/-in mit 5 SternenZustand: Neu
EUR 55,90
EUR 60,00 VersandVersand von Deutschland nach USAAnzahl: 1 verfügbar
Taschenbuch. Zustand: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Masonry is one of the most commonly used materials not only in Albania but also worldwide for the construction of low to mid rise buildings. Recent strong earthquakes in different countries have shown that masonry buildings suffered severe damage and caused loss of lives. Therefore it is important to assess the seismic performance of these buildings and based upon this evaluation, techniques should be developed for the strengthening of building stock against future earthquake damages. The purpose of this study is to evaluate the seismic performance of three residential buildings with selected template designs in Albania considering the nonlinear behavior of masonry. A nonlinear modeling method is developed in SAP2000 software and calibrated by 3Muri software. The capacity curves of the investigated buildings were determined by pushover analyses conducted in two principal directions. Seismic performance evaluation was carried out in accordance with the FEMA440 guidelines. The graphical-analytical procedure described there is used for performance evaluation. The analysis shows that two out of three selected buildings do not satisfy the required performance levels.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 140 pp. Englisch.…